Part 2: Internal Non-Hex Connection Part 2. Integral Integral SD & Internal Non-Hex Compatible Components T he Integral Implant System was developed in the early 1980's by Calcitek of Carlsbad, CA. Calcitek, acquired by Zimmer Dental , was a pioneer and market leader in HA. (Hydroxalapatite) technology in the dental market. Calcitek offered various modalities of den- tal implants and was the first company to use advanced computer imaging and milling tech- nology to noninvasively create a three-dimensional model of a patient's jawbone upon which a custom subperiosteal implant could be designed and fabricated. Integral SD Calcitek Implant System consisted of the Integral , Omniloc , Spline and Threadloc . These implants are no longer available but limited replacement components are available from Attachments International. PART 2: Integral Internal Non-Hex (flat-top) Connection Integral SD & non-hex (flat top) (implant discontinued - components available).

MD 4.0 SD 3.25 To Order: 800-999-3003 • 650-340-0393 Additional Information: www.attachments.com All product names referenced herein are trademarks of their ...

Tags:

  Relating, Integral integral

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Integral Integral SD & 4 - השתלות שיניים

1 Part 2: Internal Non-Hex Connection Part 2. Integral Integral SD & Internal Non-Hex Compatible Components T he Integral Implant System was developed in the early 1980's by Calcitek of Carlsbad, CA. Calcitek, acquired by Zimmer Dental , was a pioneer and market leader in HA. (Hydroxalapatite) technology in the dental market. Calcitek offered various modalities of den- tal implants and was the first company to use advanced computer imaging and milling tech- nology to noninvasively create a three-dimensional model of a patient's jawbone upon which a custom subperiosteal implant could be designed and fabricated. Integral SD Calcitek Implant System consisted of the Integral , Omniloc , Spline and Threadloc . These implants are no longer available but limited replacement components are available from Attachments International. PART 2: Integral Internal Non-Hex (flat-top) Connection Integral SD & non-hex (flat top) (implant discontinued - components available).

2 Omniloc & internal octagon (implant discontinued - components available). For Threadloc (implant discontinued - components available in Branemark section). For Spline SD, RD & WD (only Locator components available). Integral Compatible to the Integral , the discontinued O-butment implant was developed in the late Internal Non-Hex 1980's by Dr. David D. Dalise and was available since 1989 from the O-Company (currently (flat-top) Implants OCO BioMedical) in Albuquerque, NM. Implants Restoratively Compatible To Integral SD non-hex flat-top (discontinued) O-Butment Integral non-hex flat-top (discontinued) Anchor O-Butment Steri-Oss Original non-hex Omniloc & internal octagon (discontinued) none Omniloc Threadloc external hex (discontinued) Branemark , Regular Platform Refer to Branemark 3i Miniplant & Standard Osseotite . section for compatible IMZ Hex Head & components.

3 Innova Entegra & Restore RD & Sustain RD. Taper-Lock . Spline interdigitating projection connection none Locator parts available Omniloc Internal Octagon *1-72 (flat-top) Implants Thread Thread *1-72 Thread Thread Threadloc *1-72 Thread is approximately External Hex Implant Integral SD Integral Branemark RP Internal Non-Hex (Flat Top) Internal Non-Hex (Flat Top). Compatible Implant Diameter Implant Diameter All product names referenced herein are trademarks of their respective companies, refer to inside back cover of this manual. Copyright 2007 Attachments International, Inc., San Mateo, CA 293. Terminology of Components Part 2: Internal Non-Hex Connection Page Header Sample Guide Integral SD & MD Direct To The Implant Implant Analog UCLA Abutments Components listed on page Compatible Components Compatible Implant Name Restoration Connection Restorative Components: For ease in selecting components, the Integral Section is divided by Restoration Connection: Direct To The Implant or.

4 Indirect To An Intermediate Component (Tissue Extensions/Abutments). Overdenture Attachments, Bar Systems, Indirect Individual Parts and Tools are found following in the Indirect Section. Direct The Direct Restorative Components are the elements used to fabricate a restoration that To The Implant will be connected directly to the implant(s). Indirect The Indirect / Intermediate Restorative Components fit to an intermediate tissue extension Components (abutment) which in turn is connected to the implant(s). Implant Body: The implant body is placed into the bone for approximately 4-6 months to allow for osseointegration. The implants should not be loaded prior to osseointegration. Integral Tissue Extension: The TE (Tissue Extension) also referred to as the Shouldered Abutment, is the Integral . intermediate connector between the implant and the restoration, it may extend above the tissue.

5 In some instances, a TE extension is subgingival, to provide a more esthetic restoration. Shouldered Abutment Implant Standardization: The UMA tissue extension was developed to standardize the many different implant companies' components and instruments for a more economically con- trolled inventory and for simplicity of restorative procedures. Its tapered/hexagon fitting surface is identical, regardless of the size or type of implant employed, while its screw-in base or press fit neck is implant specific. UMA Compatibility: Implants Restoratively Compatible To Integral SD non-hex flat-top (disc.) O-Butment Integral non-hex flat-top (disc.) Anchor O-Butment Steri-Oss Original non-hex Omniloc & (discontinued) none Threadloc external hex (discontinued) Branemark, Regular Platform Refer to Branemark 3i Miniplant & Standard Osseotite section for compatible IMZ Hex Head & components.

6 Innova Entegra & Steri-Oss Hex-Loc & Taper-Lock Spline SD, RD & WD none All product names referenced herein are trademarks of their respective companies, refer to inside back cover of this manual. 294. Copyright 2007 Attachments International, Inc., San Mateo, CA. Integral SD & MD Direct To The Implant Impression Copings Compatible Components Analogs IMPRESSION COPINGS To Fit Implant Impression copings are used to take an impression of the the implant bodies are made of titanium and transfer the implant body or of the tissue extension, such as the UMA, or thread trimming. the Shouldered Abutment. The Impression copings which fit A A. SD Small Diameter Integral Implant SD MD. MD Medium Diameter Integral Implant Description Order # Order #. Impression Copings To Fit Implant Impression Copings To Fit Implant (A) 45-300080 45-400080. ANALOGS To Replicate Implant Brass analogs are used for the fabrication of a master When the UMA tissue extension is used instead of the model.

7 They replicate the fitting surface and the internal Shouldered Abutment, the standard line of UMA components threads of the implant body or the UMA tissue extension. is indicated. A. SD Small Diameter Integral Implant SD MD. MD Medium Diameter Integral Implant Description Order # Order #. Implant Body Analog, Brass (A) 45-300015 45-400015. Integral is a federally registered trademark of Zimmer Dental, Inc., Carlsbad, CA. All product names referenced herein are trademarks of their respective companies. To Order: 800-999-3003 650-340-0393. Copyright 2007 Attachments International, Inc., San Mateo, CA 294 Additional Information: Integral SD & MD Direct To The Implant UCLA, CSP Abutments Compatible Components Part 2: Internal Non-Hex Connection UCLA, CYLINDER, SCREW & PLUG (CSP). The UCLA abutment system which fits directly to the bilities.

8 Each UCLA abutment includes the castable implant, is the most widely used restorative concept for machined plastic abutment, .050" hex screw, and the screw-retained bridge type restorations. The UCLA for patented occlusal plug. The UCLA abutment is also referred Integral allows only bridge and bar type overdenture possi- to as a CSP (Cylinder, Screw and Plug). A B. SD Small Diameter Integral Implant SD MD. MD Medium Diameter Integral Implant Description Order # Order #. Cylinder, Screw & Plug (CSP). UCLA, CSP Non-Hex Cylinder (blue), Hex Screw .050" & Plug (A) 45-300252 . UCLA, CSP Non-Hex Cylinder (white), Hex Screw .050" & Plug (B) 45-400252. PARTS. UCLA, Plastic Cylinder only 45-300250 45-400250. UCLA, Screw only, Titanium .050" Hex 45-300052 45-400052. USE WITH. Impression Coping, Tapered To Fit Implant 45-300080 45-400080. Implant Body Analog, Brass 45-300015 45-400015.

9 TOOLS. Integral . Hex Driver for all .050" Screw, Healing Caps, and Guide Pins Hex Lab .050" Driver 11-000006. Hex DDS Driver12mm, long 11-000007. REAMERS. Reamer, Integral , blue handle for (no Pin Vise required) 45-000153. Reamer, UCLA Micro Carbide (requires Pin Vise 40-000150) 44-000150. Pin Vise for Carbide Reamers .002 - .130" 40-000150. Reamer Pin Vise Integral is a federally registered trademark of Zimmer Dental, Inc., Carlsbad, CA. All product names referenced herein are trademarks of their respective companies. To Order: 800-999-3003 650-340-0393. Copyright 2007 Attachments International, Inc., San Mateo, CA 295 Additional Information: Integral SD & MD Direct To The Implant Direct Titanium Posts Compatible Components Part 2: Internal Non-Hex Connection DIRECT SCREW-IN TITANIUM POSTS. The direct titanium abutment post screws into the implant on the titanium post should be done outside the oral cavity.

10 Body and may be secured with Teflon tape or thread adhe- Fabricate a soft tissue model whenever preparations are sive. The tapered posts, designed for bridge restorations, made in the laboratory. If the final restoration is to be retriev- can be altered like a preparation. The titanium posts have able, then consider set screws. an internal .050" hex for insertion and removal. Bulk grinding A. SD Small Diameter Integral Implant SD MD. MD Medium Diameter Integral Implant Description Dimensions Order # Order #. Direct Titanium Posts (A). Direct Titanium Posts x 12mm N/A 45-401220. Direct Titanium Posts x 12mm N/A 45-401230. USE WITH: Impression Coping 45-300080 45-400080. Implant Body Analog 45-300015 45-400015. TOOLS: Integral . Bio-Torq Wrench 20 N/CM 59-100020. Bio-Torq Socket 59-100190. Bio-Torq Tip Hex .050" long 59-100125. LT / RA Driver 58-100000.