Product Data Sheet00813-0100-4733, Rev NBJanuary 2011 Rosemount Factory assembled, leak-tested, and calibrated Full breadth of offering including integral, conventional, and inline designs Integral design enables flangeless valve integration 2, 3, and 5 valve configurations Compact, lightweight design Easy in-process calibration Direct-mount capabilityContentsRosemount Manifolds Selection Guide .. page 2 Valve Configuration .. page 3 Ordering Information .. page 5 Specifications .. page 11 Dimensional Drawings.. page 17 Rosemount ManifoldsProduct Data Sheet00813-0100-4733, Rev NBJanuary 2011 Rosemount Manifolds2 Rosemount Manifolds Selection GuideROSEMOUNT 304 CONVENTIONAL MANIFOLDSee Options on page 27.

Product Data Sheet 00813-0100-4733, Rev NB January 2011 Rosemount Manifolds www.rosemount.com • Factory assembled, leak-tested, and calibrated • Full breadth of offering including integral,

Tags:

  2011, January, Rosemount, January 2011 rosemount manifolds, Manifolds

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of January 2011 Rosemount Manifolds - WE …

1 Product Data Sheet00813-0100-4733, Rev NBJanuary 2011 Rosemount Factory assembled, leak-tested, and calibrated Full breadth of offering including integral, conventional, and inline designs Integral design enables flangeless valve integration 2, 3, and 5 valve configurations Compact, lightweight design Easy in-process calibration Direct-mount capabilityContentsRosemount Manifolds Selection Guide .. page 2 Valve Configuration .. page 3 Ordering Information .. page 5 Specifications .. page 11 Dimensional Drawings.. page 17 Rosemount ManifoldsProduct Data Sheet00813-0100-4733, Rev NBJanuary 2011 Rosemount Manifolds2 Rosemount Manifolds Selection GuideROSEMOUNT 304 CONVENTIONAL MANIFOLDSee Options on page 27.

2 Attaches to transmitter flange 2, 3, and 5-valve configurations Traditional (Flange x Flange, Flange x NPT) & Wafer styles Factory assembled, seal-tested, and calibratedRosemount 304 Conventional Manifold-Traditional StyleRosemount 304 Conventional Manifold-Wafer StyleROSEMOUNT 305 INTEGRAL MANIFOLDSee Options on page 27. Assembles directly to transmitter, eliminating need for flange 2, 3, and 5-valve configuration Available in Coplanar and traditional styles Compact, lightweight assembly Factory assembled, seal-tested, and calibrated 50% fewer leak points than conventional transmitter / flange / manifold interfaceRosemount 305 Integral Manifold Coplanar StyleROSEMOUNT 306 INLINE MANIFOLDSee Options on page 27.

3 Assembled directly to inline pressure transmitters Block-and-Bleed and 2-valve configurations Male or Female threaded NPT process connectionRosemount 306 Inline ManifoldProduct Data Sheet00813-0100-4733, Rev NBJanuary 20113 Rosemount ManifoldsValve ConfigurationBLOCK-AND-BLEEDThe block-and-bleed configuration is available on the Rosemount 306 Manifold for use with inline gage and absolute pressure transmitters. A single block valve provides instrument isolation and a plug provides drain/vent ManifoldTWO-VALVEThe two-valve configuration is available on Rosemount 304, 305, and 306 Manifolds for use with absolute and gage pressure transmitters.

4 A block valve provides instrument isolation and a drain/vent valve allows venting, draining, or Manifold305 & 306 ManifoldsTHREE-VALVE The three-valve configuration is available on Rosemount 304 and 305 Manifolds for use with differential pressure and multivariable transmitters. Two block valves provide instrument isolation, and one equalize valve is positioned between the high and low transmitter process (Traditional) Manifold304 (Wafer) Manifold305 ManifoldNOTETest/Vents receive plastic caps to protect threaded connections unless otherwise (Plugged) connections receive -in. NPT plugs unless otherwise ScrewProcessTransmitterTransmitterTest/V ent IsolateProcessTest (Plugged)TransmitterTest/Vent IsolateProcessEqualizeProcessIsolateIsol ateTransmitterTest (Plugged)EqualizeProcessIsolateIsolateTr ansmitterDrain/VentEqualizeProcessIsolat eIsolateTransmitterDrain/VentProduct Data Sheet00813-0100-4733, Rev NBJanuary 2011 Rosemount Manifolds4 FIVE-VALVE The five-valve configuration is available on Rosemount 304 and 305 Manifolds for use with differential pressure and multivariable transmitters.

5 Two block valves provide instrument isolation and one equalize valve is positioned between the high and low transmitter process connections. In addition, two drain/vent valves allow for controlled venting, 100% capture of vented or drained process, and simplified in-process calibration capability. 304 (Wafer) & 305 ManifoldsFIVE-VALVE NATURAL GASThe five-valve natural gas configuration is available on the Rosemount 304 and 305 Manifolds for use with differential pressure and multivariable transmitters. Two block valves provide instrument isolation and a single drain/vent valve allows for controlled venting, 100% capture of vented or drained process, and simplified in-process calibration capability.

6 In addition, two equalize valves provide extra protection from leaking to ensure DP signal integrity. 304 (Traditional) & 305 ManifoldsNOTETest/Vents receive plastic caps to protect threaded connections unless otherwise (Plugged) connections receive -in. NPT plugs unless otherwise (Plugged)Test(Plugged)TransmitterProduct Data Sheet00813-0100-4733, Rev NBJanuary 20115 Rosemount ManifoldsOrdering InformationRosemount Manifolds can be ordered as a stand-alone product or as an integrated assembly that is attached to a transmitter. Stand-Alone Manifold:1. Reference the Rosemount Manifolds Selection Guide (see page 2) for assistance on choosing the type of manifold needed.

7 2. Specify a completed model number by referencing the applicable ordering table for the selected manifold type: a. Rosemount 304 Conventional Manifold, see page Rosemount 305 Integral Manifold, see page Rosemount 306 Inline Manifold, see page / Manifold Assembly:1. Specify a completed Rosemount transmitter model number by referencing the applicable product data sheet. 2. Specify a completed manifold model number by referencing the applicable ordering table for the selected manifold type: a. Rosemount 304 Conventional Manifold, see page Rosemount 305 Integral Manifold, see page Rosemount 306 Inline Manifold, see page Verify the transmitter model number contains the correct Process Connection code or Manifold Option code for the desired transmitter manifold assembly (see Table 1).

8 Table 1. Ordering Codes for a Transmitter / Manifold AssemblyTransmitterManifoldProcess Connection Code Manifold Option Code3051S304A12 305A11 306A11 3051/2051/3095304 S6305 S5306 S51151304S6 305 306 2088304 305 306 S5 Product Data Sheet00813-0100-4733, Rev NBJanuary 2011 Rosemount Manifolds6 Rosemount 304 Conventional Manifolds Table 2. Rosemount 304 Conventional Manifold Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best Expanded offering is subject to additional delivery lead Description0304 Conventional ManifoldManufacturerStandardStandardRRos emount Inc.

9 Manifold StyleStandardStandardTTraditional (Flange x Flange or Flange x NPT) ExpandedW(1)WaferManifold TypeStandardStandard2(2)2-valve 33-valve 5(3)5-valve 6(2)5-valve Natural Gas Metering Pattern Expanded7(2)(4)2-valve (per ASME [ANSI] Power and Piping Code)8(2)(4)3-valve (per ASME [ANSI] Power and Piping Code)BodyBonnetStemTipStandardStandard23 16 SST316 SST316 SST316 SST 5CS316 SST316 SST316 SST Process Connection StyleStandardStandardB1/2-14 NPT F(2)Flanged Packing MaterialStandardStandard1 PTFE Expanded2(1)Graphite-basedBoltsStandardS tandard1 For assembly to 2051/3051 Traditional Flange 2 For assembly to 2051/3051/3095 DIN Compliant Traditional Flange 3 For assembly to 2051/3051/3095 Coplanar Flange Expanded4 For assembly to 1151 (Ranges 3-5)OptionsMounting BracketsStandardStandardVC(2)Manifold Heavy Duty Mounting Bracket, CS for Traditional Style VS(2)Manifold Heavy Duty Mounting Bracket, SST for Traditional Style B4(3)Manifold SST Mounting Bracket for 2-in.

10 Pipe mount with series 300 SST bolts for wafer style AdaptersStandardStandardDF(5)1/2-14 NPT Female Flange Adapter DT(5)1/2-in. ferrule flange adapter DQ(5)12 mm ferrule flange adapter Product Data Sheet00813-0100-4733, Rev NBJanuary 20117 Rosemount ManifoldsBolt MaterialStandardStandardL4(6)Austenitic 316 SST Bolts L5 ASTM A 193, Grade B7M Bolts L8 ASTM A 193, Class 2, Grade B8M Bolts Material Recommendations for NACES tandardStandardSG(1)(7)Sour Gas (Meets NACE MR 0175 / ISO 15156, MR 0103) CleaningsExpandedP2(8)Cleaning for special serviceHeater Block KitsStandardStandardSBSteam block kit, -in. NPT connection Typical Model Number:_ 0304_R_T_3_2_B_1_1_VS(1) Only allowed with Material of Construction code 2.