Example: tourism industry

LIIFEE--LIIN E Wavve Rider r I - Crucialpower.com

Central Lighting Inverter Emergency Power Systems LIFE-LINE. The Wave Rider I incorporates state of the art technology with PWM (Pulse Width Wave Rider I. Modulated), standby design for emergency lighting applications. CENTRAL LIGHTING INVERTER. The Wave Rider Energy Conserver is available in both Fast Transfer and standby models. When utility power fails, the Inverter provides Leader in LED! uninterrupted output power to the emergency lighting circuits, in compliance with UL924 Title 24 inspired Life Safety Code for 90 minutes of egress illumination.

A Full Line Power Protection Company. LIIFEE--LIIN E Wavve Rider r ™ I CENTRAL LIGHTING INVERTER Central Ligh ting Inverter E mergency Power Syste ms The Wav e R iderI incorporates state of the

Tags:

  Riders, E mergency, Mergency

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of LIIFEE--LIIN E Wavve Rider r I - Crucialpower.com

1 Central Lighting Inverter Emergency Power Systems LIFE-LINE. The Wave Rider I incorporates state of the art technology with PWM (Pulse Width Wave Rider I. Modulated), standby design for emergency lighting applications. CENTRAL LIGHTING INVERTER. The Wave Rider Energy Conserver is available in both Fast Transfer and standby models. When utility power fails, the Inverter provides Leader in LED! uninterrupted output power to the emergency lighting circuits, in compliance with UL924 Title 24 inspired Life Safety Code for 90 minutes of egress illumination.

2 The Wave Rider is the best design solution for emergency lighting power for a wide Applications range of commercial and industrial For a wide range of applications. commercial and industrial applications, from 2,100 to KEY FEATURES of the Wave 17,000 watts. Rider : Typical installations: I Fast Transfer - Standby and I Office Buildings Double Conversion, no-break I Factories online systems available. I Hospitals I Efficiency: 98% Standby - Fast I Hotels & Motels Trans / 94% On-Line I Schools & Universities I Built-in Power Factor Correction I Shopping Centers (Saves approx.)

3 10% on utility bill) I Casinos I Automatic monthly and annual self I Airports testing I Military Installations I Latest technology microprocessor I Apartment Buildings I Supermarkets controlled electronics with PWM t Size I Train & Bus Terminals Cabin7ekW. New .2. (Pulse Width Modulated) design for 5 5- 1. true Sine Wave output. I Continuous self-diagnostic and self- testing system. I LCD backlit panel for comprehensive monitoring of power line conditions and Inverter status. to 17 KW, I Optional remote monitoring, including the advanced Global Monitoring Single Phase (UPS or IPS).

4 System (GMS). I Sealed maintenance-free lead Standby or Fast Transfer (under 2ms). calcium batteries with 10 year prorata warranty. HID, Incandescent, Fluorescent, LED. I Battery Exerciser I Battery Sentinel Battery Monitoring 120, 208, 240, 277, or 480 Volts System Listed to UL924 Lighting I Modular cabinet design for ease of installation, small footprint with and UL1778 UPS Standards, by CSA. A Full Line Power Protection Company. shallow 18 depth, convenient front access, optional certified Zone 4. Seismic brackets available. I Generator Compatible I 1 Year Warranty OPTIONAL INPUT PROTECTION: Input Circuit Breaker Wave Rider I Specifications provided protection to the unit, load, and personnel.

5 Input POWER RATING: , 3, 5, , 10, , 15, and 17 KW Circuit Breaker is rated at (10 KAIC) standard and higher interruption up to 65 (KAIC) optional. Input Voltage: 5KW; 120, 208, 240, 277, or 480 VAC (-20% to +15%) OUTPUT PROTECTION: Internal Electronic overload ; 208, 240, 277, or 480 VAC (-15% to +15%); 120V - Special Order protection. Circuit breaker provides inherent over-load protection. Factory selectable voltage 120, 208, 240, or Output Voltage: 120, 208, 240, 277, or 480 VAC. 277 for input or output voltages. If input is different from OUTPUT FREQUENCY (Inverter Operation): 60Hz + output or output different from input, an internally mounted VOLTAGE REGULATION: +3% transformer is required.

6 SURGE PROTECTION: The inverter will protect itself and OUTPUT WAVE FORM: Sine-wave the load against surge as defined in ANSI/IEEE NOISE ISOLATION: -120 dB. Common-Mode.; 60 dB. Transverse-Mode category A and B. ISOLATION: Output is completely isolated from input, and EFFICIENCY: 98% Standby - Fast Transfer / 94% Online with multi voltages, when input & output is different. CREST FACTOR: 3:1 Typical (may vary by model) BATTERY: Sealed maintenance free (SMF), Lead Calcium ENVIRONMENTAL: Battery Management System: Utilizes a microprocessor Humidity: 0-95% RH w/no condensation technology to monitor the batteries critical levels and apply Operating temperature: charging cycles in a method to substantially increase UPS: -0 to 40 C.

7 (32 to 104 F) battery life. BATTERY: 20 to 25 C (68 to 77 F) HOUSING: Free standing NEMA 1 Enclosure powder coated Storage temperature: -20 to 25 C. (-4 to 77 F) paint Front access only Multiple conduit entries Refer to chart for dimensions SAFETY AGENCIES: CSA Listed to UL 924, UL 924A, UL1778, NFPA101, NFPA70, NEC, and OSHA. RECHARGE TIME: per conform UL924. Input/Output MODEL DC BTU/ Cabinet Size Wgt OPTIONS. KW Secondary Auxiliary Circuit Breakers: Normally On, Voltages NUMBERS Volts Hr (W x H x D ) (lbs) I. Normally Off, Normally Off w/ Delay, Trip Alarm 120/120 826 Form C' Contacts (5), ( ).

8 208/208 826. I. Secondary Normally On/Off Terminal Block selection 240/240 96 859 39 x 48 x 18 826. I. 277/277 826 I Remote Status Panel Unit with Audio Alarm and Silence 120,208,240,277,or 480 ** 896 Switch Local Audio Alarm with Silence Switch 120/120 996. I. 208/208 996 I Make Before Break Internal Maintenance Bypass Switch 240/240 96 1227 39 x 48 x 18 996 I External Maintenance Bypass Switch (wrap around type). 277/277 996 Main Input and/or Output Circuit Breaker (with custom 120,208,240,277,or 480 ** 1066. I. KAIC). 120/120 1214 Built-in Secondary Distribution 208/208 1214.

9 I. Input Transient Voltage Surge Suppressor (TVSS). 240/240 120 1875 39 x 68 x 18 1214. I. 277/277 1214 I Harmonic Tolerance (up to K-50). 120,208,240,277,or 480 ** 1284 I EMI Filter 208/208 2190 I Certified Zone 4 Seismic Bracket * 240/240 51 x 70 x 2190 Extended Warranty and Service Plans 120 2819. 277/277 2190. I. Spare Part Kits Available 208, 240, 277,or 480 ** 2350. I. Long Life Battery 208/208 WR010B1300N1 2695. I. Global Monitoring System (GMS). 240/240 WR010D0400N1 51 x 70 x 2695. I. *10 192 3755 LOCAL. 277/277 WR010R2500N1 2695 I Local PC via RS232 and RS485.

10 208, 240, 277,or 480 **WR010X5800T1 2870 I Event logging up to 500. 208/208 WR012B1300N1 3557 REMOTE. 240/240 WR012D0400N1 51 x 70 x 3557 I Dial-up * 192 4696. 277/277 WR012R2500N1 3557 - Voice (10 event logging), numeric pager 208, 240, 277,or 480 **WR012X5800T1 3777 - Voice, data, fax, pager, PC, e-mail, event logging up 208/208 WR015B1300N1 4172 to 500. 240/240 WR015D0400N1 51 x 70 x 4172 - Voice, data, fax, pager, PC, e-mail, and *15 240 5608 measurement (500 event logging plus graphic). 277/277 WR015R2500N1 4172. I Web/SNMP: 208, 240, 277,or 480 **WR015X5800T1 4512.