Example: tourism industry

Liquatite Flexible Conduit - tnb.ca

ConduitLiquatite Application Guide..G2 G4 Flexible Conduit Steel Core ..G5 G16 Flexible Conduit Aluminum Core ..G17 G20 Flexible Conduit Shielding Core ..G21 G22 Flexible Conduit Nonmetallic G24 Tools and Accessories ..G25 Engineering Information ..G25 G26 Packaging ..G27 Conduit Dimensional Data ..G28 G29 Chemical Resistance G33 Table of ConduitLiquatite Application Guide* A=Continuous flexing B=Small bend radius C= Flexible D=Pliable (static)** S=Steel A=Aluminum B=Bronze** P=PVC U=Pu T=TPR N=Nylon Conduit Type Page Flexibility* Metal Used** Plastic** UsedHigh Mech. StrenghtListed for Direct Burial Halogen FreeLow Fire HazardAccepts Std. Liquidtight FittingsSelf Extinguish EMI/RFI Shielding ApprovalTYPE-LTG5 BSPpp. B82-B100 JICTYPE-LORG6 BSPpp. B82-B100 JICTYPE-EFG6 BSPpp. B82-B100 JICTYPE-LAG7 CSPXXpp. B82-B100 XTYPE-CBLAG8 CSPXXpp.

The flexible inner core is made from a spiral wound strip of corrosion resistant plating steel. The 1/4 through 2 inch trade sizes are squarelock formed and, with the exception of

Tags:

  Flexible, Conduit, Liquatite flexible conduit, Liquatite

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Liquatite Flexible Conduit - tnb.ca

1 ConduitLiquatite Application Guide..G2 G4 Flexible Conduit Steel Core ..G5 G16 Flexible Conduit Aluminum Core ..G17 G20 Flexible Conduit Shielding Core ..G21 G22 Flexible Conduit Nonmetallic G24 Tools and Accessories ..G25 Engineering Information ..G25 G26 Packaging ..G27 Conduit Dimensional Data ..G28 G29 Chemical Resistance G33 Table of ConduitLiquatite Application Guide* A=Continuous flexing B=Small bend radius C= Flexible D=Pliable (static)** S=Steel A=Aluminum B=Bronze** P=PVC U=Pu T=TPR N=Nylon Conduit Type Page Flexibility* Metal Used** Plastic** UsedHigh Mech. StrenghtListed for Direct Burial Halogen FreeLow Fire HazardAccepts Std. Liquidtight FittingsSelf Extinguish EMI/RFI Shielding ApprovalTYPE-LTG5 BSPpp. B82-B100 JICTYPE-LORG6 BSPpp. B82-B100 JICTYPE-EFG6 BSPpp. B82-B100 JICTYPE-LAG7 CSPXXpp. B82-B100 XTYPE-CBLAG8 CSPXXpp.

2 B82-B100 XTYPE-CSAG9 CSPXpp. B82-B100 XTYPE-ATLAG10 CSPXXpp. B82-B100 XTYPE-ATG11 BSPpp. B82-B100 TYPE-ATXG11 BSTXp. B85 TYPE-ALTG20 CAPpp. B82-B100 TYPE-CEAG13 CSUXXpp. B82-B100 XTYPE-ACEAG18 CAUXXpp. B82-B100 XTYPE-ZHLAG12 CSUXXXXpp. B82-B100 XTYPE-LASG21 CSPXXpp. B82-B100 XXTYPE-EMSG22 CBPpp. ConduitLiquatite * A=Continuous flexing B=Small bend radius C= Flexible D=Pliable (static)** S=Steel A=Aluminum B=Bronze** P=PVC U=Pu T=TPR N=Nylon Conduit Type Page Flexibility* Metal Used** Plastic** UsedHigh Mech. StrenghtListed for Direct Burial Halogen FreeLow Fire HazardAccepts Std. Liquidtight FittingsSelf Extinguish EMI/RFI Shielding ApprovalTYPE-EMCSG22 CBPpp. B82-B100 XXTYPE-BRG14 CSXpp. B108-B115 TYPE-ABRG19 CApp. B108-B115 TYPE-ABRHG17 CApp. B108-B115 TYPE-USLG16 BSpp. B108-B115 TYPE-SLG15A, BSpp. B108-B115 TYPE-VJCG16A, BSPpp. B108-B115 TYPE-UGG15 CSpp.

3 B108-B115 TYPE-LNM-PG23 APpp. B101-B103 XTYPE-NMCG24 CPXXpp. B103-B109 XTYPE-NMTG24 APXpp. B103-B109 XApplication ConduitLiquatite Conduit TypeTemperature RangeGeneral Chemical Resistance See chart on page G30 C-60 -40 -20 0 +50+60 +75 +80 +90+105 +150 F-76 -40-4 +32 +122 +140 +167 +176 +194 +221 +302 OilsAcidsTYPE-LTIIIIIIIIIIXXTYPE-LORIIII IIIIIIXXTYPE-EFIIIIIIIIIIXXTYPE-LAIIIIII IIIIXXTYPE-CBLAIIIIIIIIIIXXTYPE-CSAIIIII IIIIIXXTYPE-ATLAIIIIIIIIIIXXTYPE-ATIIIII IIIIIXXTYPE-ATXIIIIIIIIIIXTYPE-ALTIIIIII IIIIXXTYPE-CEAIIIIIIIIIIXTYPE-ACEAIIIIII IIIIXTYPE-ZHLAIIIIIIIIIIXTYPE-LASIIIIIII IIIIXXTYPE-EMSIIIIIIIIIIXXTYPE-EMCSIIIII IIIIIXXTYPE-BRIIIIIIIIIITYPE-ABRIIIIIIII IITYPE-USLIIIIIIIIIITYPE-SLIIIIIIIIIITYP E-VJCIIIIIIIIIIXXTYPE-UGIIIIIIIIIITYPE-L NM-PIIIIIIIIIIXXTYPE-NMCIIIIIIIIIIXXTYPE -NMTIIIIIIIIIIXXTYPE-CLIIIIIIIIIIXTYPE-C LLIIIIIIIIIIXTYPE-CCGIIIIIIIIIIXTYPE-CLR IIIIIIIIIIXTYPE-CLFRIIIIIIIIIIXA pplication ConduitLiquatite Type LTType LTA general

4 Purpose, Flexible liquidtight steel Conduit designed for a variety of installations requiring motion, vibration and bending. It offers good mechanical and moisture protection to enclosed conductors. ConstructionThe Flexible inner core is made from a spiral wound strip of corrosion resistant plating steel. The 1/4 through 2 inch trade sizes are squarelock formed and, with the exception of the 1/4 inch size, contain a nylon cord pack-ing within the larger sizes are constructed with a fully interlocked strip to add strength and to pre-vent Flexible yet durable PVC jacket is extruded over this core creating a liquidtight Conduit resistant to most oils, acids and vapors pres-ent in industrial environments. Refer to the Conduit Chemical Resistance Chart beginning on p. Conduit is used extensively in the ma-chine tool and other industrial environments where flexibility is necessary for installation and maintenance or where vibration and movement must be absorbed.

5 The inherent sunlight resistance of PVC enables this product to be used in outdoor applications. Compatible with standard liquidtight fittings. The construction of this Conduit conforms to, and is suitable for use with Sections 16 & of the Electrical Standard for Industrial Machinery (ANSI/NFPA-79).Working Temperatures-20 C to 80 CListing / CertificationJIC manufactured in accordance with the dimensions and specifications as outlined by the Joint Industrial Council Standard for Mass Production Equipment and Machine ColoursMachine tool grey and black. Other colours available upon request. Part numbers listed designate grey 2-1/2 in. - 6 with Filler 5/16 in. - 2 Size (in.)Cat. Content* (m)Cat. Content* (m)Cat. Content* (m)Inside Bend RadiusWeight kg/30min.(mm)1 ( )85 ( )83 ( )91 ( )113 ( ) ( )241-1/4LT125-1515LT125-7575 ( )311-1 ( ) ( ) ( ) ( )259 See Chart on p.

6 G28 for dimensions and tolerances * See p. G27 for label and packaging detailJICS teel ConduitLiquatite Type EFType LOR This product is offered as a non-UL oil-resistant Conduit that incorporates a high quality PVC The LOR is ideally used in situations where a UL listing or CSA certification is not a factor but where a Flexible Conduit must withstand exposure to many harsh chemicals, oils, UV, etc. This Conduit conforms to Section of the Electrical Standard for Industrial Machinery. (ANSI/NFPA-79) Compatible with Standard Liquidtight Fittings. Working Temperatures -20 C to 60 C intermitting to 90 CStandard Colours Machine tool grey and black. Other colours available upon request. Part numbers listed designate grey For a UL listed version, consult your Regional Sales Office for Type EFThis Flexible liquidtight Conduit is a competi-tive grade version of our Type LT.

7 It conforms to both the JIC standards for dimensions and general construction, and to Section of the Electrical Standard for Industrial Machinery (ANSI/NFPA-79).ConstructionThe Flexible inner core is constructed from a helically formed strip of corrosion resistant steel. A liquidtight PVC jacket is then extruded over the core. ApplicationsGeneral installations requiring some move-ment and protection for contained con-ductors. Forms a liquidtight system when installed with standard fittings for use indoors or Temperatures -20 C to 80 C Standard Colour Machine tool greyJICT rade Size (in.)Cat. Content* (m)Cat. Content* (m)Cat. Content* (m)Inside Bend RadiusWt. kg/30min.(mm)3 ( )191 ( )113 ( ) ( )241-1 ( )311-1 ( ) ( )532-1 ( ) ( )1183-1 ( ) ( ) ( ) ( )259 See Chart on p. G28 for dimensions and tolerances* See p. G27 for label and packaging detailTrade Size (in.)

8 Cat. Content* (m)Cat. Content* (m)Cat. Content* (m)Inside Bend RadiusWt. kg/30min.(mm)3 ( )91 ( )113 ( ) ( )201-1 ( )251-1 ( ) ( )5 See Chart on p. G28 for dimensions and tolerances * See p. G27 for label and packaging detailSteel CoreType ConduitLiquatite Type LAA Flexible liquidtight steel Conduit which is both listed UL and certified CSA. It offers outstanding protection against wet, oily conditions and is permitted for use in exposed or concealed Flexible inner core is made from a spiral wound strip of heavy gauge, corrosion resistant, hot-dipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes are square lock formed and include an integral bonding strip of copper that is enclosed within the convolutions throughout its entire length. The 1-1/2 through 4 inch trade sizes are designed with a fully interlocked strip. The liquidtight jacketing material is of a high quality, rugged, flame retardant Flexible PVC compound which resists oils, mild acids and exposure to sunlight.

9 For further information, refer to the Conduit Chemical Resistance chart beginning on p. Conduit is intended for installation with Rule 12-1300 of Canadian Electrical Code (CEC) Part I use of a separate bonding conductor is mandatory in accordance with CEC Rule 12-1306 for Ordinary use of Liquidtight Flexible Conduit with sign and Outline Lighting are in accordance with CEC Rule 34-400 (2):- Listed and marked for direct burial and in poured concrete- For containment of 600-volt and lower potential circuits- Sunlight resistantWorking Temperatures-30 C to 80 C (dry) / 60 C (wet) and 70 C (oil)Listing / CertificationCertified. Conforms to CSA No. 56 for use per CEC Section Conforms to UL Standard ANSI/UL-360 for Liquidtight Flexible Steel ColoursMachine tool grey, and black. Other colours available upon request. Blue is commonly used for computer room installations.

10 See TYPE CBLA on p. 1-1/2 in. - 4 with filler3/8 in. - 1-1/4 Size (in.)Cat. Content* (m)Cat. Content* (m)Cat. Content* (m)Inside Bend RadiusWeight kg/30min.(mm)3 ( )131 ( )153 ( ) ( )371-1 ( )461-1 ( ) ( )662-1 ( ) ( )1143-1 ( ) ( )154 See Chart on p. G28 for dimensions and tolerances* See p. G27 for label and packaging detailSteel CoreType ConduitLiquatite Type CBLAC omputer Blue LA is a liquidtight Flexible steel Conduit commonly used for computer room installations. The blue jacket colour easily identifies circuitry for computer power has a Flexible inner core made from a spiral wound strip of heavy gauge, hot-dipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes contain an integral bonding strip of copper. The 1-1/2 and larger sizes are designed with a fully interlocked jacketing material is a rugged flame retardant Flexible blue PVC.


Related search queries