Load Centers and Circuit Breakers Section 1 - ABB

Load Centers and Circuit BreakersSection Products BuyLog1-1 Rev. 1/19 Data subject to change without noticeQ-Line Circuit Breakers product Features and Gold Load Centers product Features and 1-3 PowerMark Gold and Plus Load Centers product Number Plug-in Circuit Purpose Circuit Gold and Plus single -Phase Load Centers Main Lug Convertible to Main Main Breaker Factory Plus Three-Phase Load Centers Main Circuit Breakers or Main Lugs Factory 1-14 PowerMark Gold Load Centers Specialty Gold Meter Socket Load 1-18 Field Installed Centers and Meter Socket Load Centers Purpose Circuit Breakers PowerMark Gold Main Circuit Breakers Arc Fault Circuit Interrupter Dual Function

PowerMark Gold and Plus Single-Phase Load Centers— ... 1-2 GE Products BuyLog. Section 1 Rev. 1/19 go.abb/industrial GE Products BuyLog 1-3 Data subject to change ... 1UL Listed as HACR (heating, air conditioning and refrigeration). 2UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.

Tags:

  Product, Single, Refrigeration

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Load Centers and Circuit Breakers Section 1 - ABB

1 Load Centers and Circuit BreakersSection Products BuyLog1-1 Rev. 1/19 Data subject to change without noticeQ-Line Circuit Breakers product Features and Gold Load Centers product Features and 1-3 PowerMark Gold and Plus Load Centers product Number Plug-in Circuit Purpose Circuit Gold and Plus single -Phase Load Centers Main Lug Convertible to Main Main Breaker Factory Plus Three-Phase Load Centers Main Circuit Breakers or Main Lugs Factory 1-14 PowerMark Gold Load Centers Specialty Gold Meter Socket Load 1-18 Field Installed Centers and Meter Socket Load Centers Purpose Circuit Breakers PowerMark Gold Main Circuit Breakers Arc Fault Circuit Interrupter Dual Function

2 GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker Ground Fault with Self-Test Feature Ground Fault with Equipment Protection Switching Neutral HID Lighting Breaker High Magnetic Breaker Molded Case Switch Surge Arrester TQ BreakerCopper stabs, tin-plated for corrosion resistance, make the connection reliable and permanent. Heat-resistant thermoset cases and covers add stability and structural are easy to spot because handles trip to the center dedicated calibration screw is cemented (notsimply papered over) to prevent shifting. The result isstable calibration for optimum trip 1/2 , THQP Breakers are half the width of standard Breakers , permitting the use of smallerload Centers that save money and space in both new construction and service upgrades.

3 Theyfeature the same high-performance design, and meet the same stringent standards as otherQ-Line Breakers . Our 1 THQL will remain the breaker of choice for many contractors. In appli-cations where space and cost are not critical, they re an excellent choice. But when size andmoney are driving considerations, THQP Breakers are the smart circuitbreakers make iteasy and efficientto install exteriormain surgearresters are easy toinstall and protect thewhole house comput-ers, fax machines, televi-sions, stereos, VCRs andother sensitive electronic equipment from destructive protection against all-too-common electrical fires comes from the new technology built into GE s arc fault Circuit interrupters (AFCIs).

4 With its ability to detect and interrupt arcing caused by damaged wire insulation or a frayed exten-sion cord, the AFCI takeshome and family protectionto a new, higher NEC requires ground fault protection of receptacles outdoors andin garages, bathrooms and spa areas. These ground fault Circuit interrupters eliminate the need for separate GFCI receptacles, protectagainst short circuits and overloads, and prevent shock by detectingvery low levels of current leaks and immediately shutting off power tothe 1 Load Centers and Circuit BreakersQ-Line Circuit BreakersReliability and 1/19 Data subject to change without noticeGE Products BuyLog1-2 Section Products BuyLog1-3 Rev.

5 1/19 Data subject to change without noticePowerMark Gold load Centers lower your costs by making installa-tion faster and easier, increasing application flexibility and reduc-ing inventory requirements. At the same time, they deliver obviousand significant advances in design, function and quality. UL Listed (Panelboards No. 67) Service Barriers included for factory installed main Circuit breaker and main Circuit breaker kits (required to meet UL67 for service entrance applications) Suitable for Use as Service Entrance Equipment when installed in accordance with National Electrical Code 60 C/75 C Conductor Rating single phase, 40-225A, 2-42 circuits Main lug models field convertible to main breaker Main breaker 22kAIC standard - factory installed All load Centers top or bottom feed Indoor and outdoor rated enclosures Indoor fronts combination surface/flush Copper bus with tin plating standard1 Split neutrals extend the full length of the interior for ease of wiring Entire main lug line converts easily to main breaker Combination surface/flush front with spring-reinforced pan Combination slotted/Robertson square-drive screws on neutral,2ground.

6 Front and breaker lugs Front packed in inner carton for added protection Field installable feed-through lugs up to 200A Straight-through main wiring Main breaker is clearly marked and Circuit numbers are stampedon front Isolated ground bar is available Compact box maintains optimum wire-bending spaceSafety accessories convenient and easy to install THQLSURGE whole house surge protector Arc fault Circuit interrupter breaker, 1- or 2-pole Ground fault Circuit interrupter breaker, 5mA and 30mA Generator transfer panel 30A or 60A, indoor or outdoor GE AC disconnects Service Barrier Kits Packaging features comprehensiveselection and application data. Fronts are packed in inner cartons for added protection during shipmentand at the job lug load Centers offer an economical solution for subpanels and similar main lug units 125A and above convert easilyto main s residential load Centers reach into commercial applications as well, with riserpanels, auxiliary gutters, three-phase unitswith standard 22kAIC ratings, and all theaccessories needed to complete the PowerMark Gold line includes a wide range of outdoor as well as indoor complete family of meter socket load Centers ring styleand ringless, wide and narrow, meter mains.

7 Farm panels andmore deliver specialized solutions for special slotted/Robertsonsquare-drivespeeds screwwiringAll holes ratedfor 14-4 wire100% rated split neutral on each side2 Accepts GE Q-Line branch Circuit Breakers , includingGE s exclusive 1/2" THQPsMain breaker configura-tion allows top or bottomfeed without modificationTie bar may beremoved to split neutral/groundOne-piece interior removes and reinstalls easilyFull-length neutrals are easier to wire,2reducing installation time and costMinimum 100% neutral terminationsSturdy copper bus and galvanized boxincrease durability and reliabilityLoad Centers and Circuit BreakersPowerMark Gold Load CentersHighest Quality and Convenience1 Three-phase PowerMark Plus load Centers have aluminum bus with copper breakermounting Circuit and and Options Door lock and handle Hardware kits Equipment ground kits Main breaker retainers Sub-feed and feed-thru lugs Neutral kits Front filler plates Universal raintight hubs Handle lock and tiesProduct Number Guide for Load Centers ( product )

8 Number for illustrative purposes only)204 CBCU42 MTGE IdentificationType M = Main breaker L = Main lug LM = Convertible PL = Main lug (Thermoplastic)Insert for PowerMark Gold CU = Copper Bus 42 = Copper Bus Full 42 Circuit panelMaximum Number 1" Spaces 2, 4, for 3-Phase 4-WireLoad CentersInsert for Specials G or T = Factory installed ground bar B = Bottom feed main breaker FL = Factory installed feed-through lugs D = Optional door for 6-8 Circuit panel. (Doors standard on all units 12 circuits or greater) W = White Front Enclosure Type C = Combination surface/flush F = Flush S = Surface R = OutdoorBus Ampere Rating 40 = 40 Amps 20 = 200 Amps 70 = 70 Amps 22 = 225 Amps 10 = 100 Amps 12 = 125 Amps 15 = 150 AmpsProduct Number Guide for Q-Line Plug-in Circuit Breakers ( product number for illustrative purposes only)

9 1*115 QLHTGE IdentificationInterrupting Rating H = 10kAlC HH = 22kAlC X = 65kAlCGround Fault/Arc Fault Circuit Interrupter AF2 = 1- & 2-pole Combination Arc Fault Circuit Interrupter GFEP = 1- & 2-pole Ground Fault with Equipment Protection Interrupter 30 mA GFT = 1- & 2-pole Ground Fault with Self-Test Feature Interrupter - 5 mA DF = 1-pole Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit InterrupterPoles (1, 2, 3)Type QL = 1" plug-in QP = 1/2" plug-in QB = 1" bolt-onAmpere RatingVoltage 1 = 120/240V 2 = 240V*Omit character for THQP Breakers , which are all 120 1 Load Centers and Circuit BreakersPowerMark Gold and Plus Load CentersProduct Number 1/19 Data subject to change without noticeGE Products BuyLog1-4 Section Products BuyLog1-5 Rev.

10 1/19 Data subject to change without noticeLoad Centers and Circuit BreakersQ-Line Plug-in Circuit BreakersUL Listed (Molded Case Circuit Breakers No. 489)Federal Government Specification Qualified (WC-375B)60 C / 75 C Conductor RatingQuick Make, Quick BreakBox Type TerminalsQ-Line Plug-in Circuit Breakers 10,000 AIC 22,000 AIC 65,000 AIC Type THQP 1/2-inch Module Type THQL 1-inch Module Type THHQL 1-inch Module Type TXQL 1-inch Module120/240 Vac120/240 Vac120/240 Vac240 Vac120/240 Vac240 Vac120/240 VacAmpereProductProductProductProductPro ductProductRatingNumberNumberNumberNumbe rNumberNumberSingle Pole1152 THQP115 THQL1115 THHQL1115 TXQL1115202 THQP120 THQL1120 THHQL1120 TXQL112025 THQP125 THQL1125 THHQL1125 TXQL112530 THQP130 THQL1130 THHQL1130 TXQL113035 THQP135 THQL1135 THHQL1135 40 THQP140 THQL1140 THHQL1140 45