1 LP-100A Digital Vector RF Wattmeter Operations Manual Covers LP-100A serial numbers starting at 2020, and firmware beginning at 2 Compliance Federal Communications Commission Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. European Union Declaration of Conformity Telepost Inc. declares that the product: Product Name: Digital Vector RF Wattmeter Model Number:LP-100(A) Conforms to the following Product Specifications: EN 55022: 1998 Class B following the provisions of the Electromagnetic Compatibility Directive 89/336/EEC, tested and verified 3-17-2006 at U

50 mW to 3000W with three autoranging scales (options for 5 & 10KW) Power display resolution of 0.01 to 1W depending on scale Frequency coverage of 1.8-54 MHz, with automatic per-band correction Z, R, |X| display from 0-999.9 ohms each Separate coupler with 50 ohm ports for uncluttered desktop

Tags:

  A100, Autoranging, Lp 100a

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of LP-100A - Telepost Inc

1 1 LP-100A Digital Vector RF Wattmeter Operations Manual Covers LP-100A serial numbers starting at 2020, and firmware beginning at 2 Compliance Federal Communications Commission Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. European Union Declaration of Conformity Telepost Inc. declares that the product: Product Name: Digital Vector RF Wattmeter Model Number:LP-100(A) Conforms to the following Product Specifications: EN 55022: 1998 Class B following the provisions of the Electromagnetic Compatibility Directive 89/336/EEC, tested and verified 3-17-2006 at University of Michigan Radiation Laboratory.

2 Industry Canada Compliance Statement Canada Digital Apparatus EMI Standard This Class B digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe B respecte toutes les exigences du Reglement sur le material brouilleur du Canada. Copyright and Trademark Disclosures LP-100(A) is a trademark of Telepost Inc. Windows is a registered trademark of Microsoft Corporation. Teflon is a registered trademark of du Pont de Nemours and Company. PICmicro is a registered trademark of MicroChip Technology Inc.

3 Material in this document copyrighted 2013 Telepost Inc. All rights reserved. All firmware and software used in the LP-100(A), VCP and Plot programs copyrighted 2004-2013 Telepost Inc. All rights reserved. MicroCode Loader is a copyrighted program from Mecanique, 3 Table of Contents Introduction .. 4 Connections .. 5 Operation Overview .. 6 Detailed Operation .. 9 Setup Menus ..14 Circuit Description ..16 Schematic ..18 Software ..20 Specifications ..26 Warranty ..27 Appendix ..28 Calibration ..31 Note: Calibration info is provided for reference.

4 LP-100A is factory calibrated with NIST traceable instruments. 4 Introduction The LP-100A is designed as an accurate instrument for monitoring station performance. It provides a number of unique features not seen before in a ham radio wattmeter. The most obvious of these is the vector display. This display shows the complex impedance of the load in two ways. The top line of the display shows impedance in polar , magnitude and phase of the impedance. The bottom line shows the real and imaginary components of , R +jX. The parameters are displayed in a range of to ohms.

5 Phase is displayed in degree increments from 0-90 degrees. Features Fast, high contrast GVFD display with bargraphs for power and SWR, along with numerical readout for both Bargraphs customizable for style, decay, behavior and range Professional dBm / Return Loss display 50 mW to 3000W with three autoranging scales (options for 5 & 10KW) Power display resolution of to 1W depending on scale Frequency coverage of MHz, with automatic per-band correction Z, R, |X| display from ohms each Separate coupler with 50 ohm ports for uncluttered desktop Peak-hold numerical power readout with "hang" characteristic for power and SWR SWR accuracy <.

6 15 (5%) from about .1W to 3000W, .05 typical Power accuracy is 3% typical at any rated power level or frequency from 1W to 3000W after calibration, usable to Can be easily matched in the field to external standard to within on each band Power display is Fwd or Net power delivered to the load ( Fwd minus Ref power). SWR Alarm system with set points for Off, , , and user setting. Includes snooze button for tuning, and power threshold. Windows freeware Virtual Control Panel for software / remote control Support within TRX-Manager for direct remote monitoring Advanced automatic charting capability for SWR, RL, Z, R, X , reflection coefficient and Smith Chart Built-in bootloader to allow for firmware upgrades to be downloaded and installed.

7 Call sign screen saver to extend life of display, scrolls a full screen call sign across the screen. Call sign is set in Setup screen. Direct input for bench testing & field strength measurements, -15 to +33 dBm. Conforms to FCC Part 15 A & B, ICAS and CE radiated emission limits, tested and verified by accredited lab This manual will address the operation of the LP-100A . For those who are interested, there is also a section on Calibration, even though this is already done at the factory. There is an Appendix with interesting information the user might find useful.

8 RoHS Statement The EU adopted a set of standards for the Reduction of Hazardous Substances in July 2006. LP-100A s shipped to EU are 100% RoHS compliant in both parts and manufacturing processes. There may be some long term reliability issues associated with RoHS compliant solders and parts, but unlike some industries like aerospace and medical, we are not exempt from these rules. We have seen no indication of reduced performance or longevity. 5 Connections Power: 11-16 VDC @ 330 mA max., center pin +, ID. The lead with the white stripe on the supplied cable is + PTT: Loop the PTT (amp keying) between your amplifier and rig through the LP-100A using RCA connectors RS-232: Connects to standard M-F straight through DB9 serial cable.

9 See manual for usage. Current/Voltage: Connect to corresponding jacks on the coupler using supplied RG-58U cables. Note: This guide assumes you are using firmware version or newer. 6 Operation Overview Operation of the LP-100A is straightforward, and designed to require a minimum of input. There are only three buttons which are used in combination to access all the menus on the LP-100A . There are five main modes for the LP-100A , which are accessed by momentarily pressing the Mode button. The mode status is saved in non-volatile memory, and the LP-100A will return to the saved mode upon powering up.

10 There is also an automatic three-step screen saver mode which dims the screen after 1 second of inactivity, scrolls your call sign across the screen after a user programmed delay time, and turns the display off after another user programmed delay time. The first step is only active in the Normal (most often used) mode. More on this below. Mode Button There are five basic modes, selectable with the Mode Normal, Vector, dBm, Field Strength and Peak-to-Average. The mode button is also used to access Setup and Calibrate modes by holding the button for 1 second to access Setup and another 1 second to access Calibration.