1 Dell EMC PowerEdge R450 Technical SpecificationsPart Number: E74 SRegulatory Type: E74S001 May 2022 Rev. A02 Notes, cautions, and warningsNOTE: A NOTE indicates important information that helps you make better use of your : A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoidthe : A WARNING indicates a potential for property damage, personal injury, or death. 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Othertrademarks may be trademarks of their respective 1: Technical 4 Chassis 5 System 6 PSU 6 Supported operating fans 7 System battery 8 Expansion card riser 8 Memory 8 Storage controller and connectors ports port 10 Serial connector 10 VGA ports 10 Video 11 Particulate and gaseous contamination 12 Thermal specificationsThe Technical and environmental Specifications of your system are outlined in this : Chassis dimensions System weight Processor Specifications PSU Specifications Supported operating systems Cooling fans Specifications System battery Specifications Expansion card riser Specifications Memory Specifications Storage controller Specifications Drives Ports and connectors Specifications Video Specifications Environmental specifications14 Technical specificationsChassis dimensionsFigure 1.
2 PowerEdge R450 Chassis dimensionsTable 1. Chassis dimensions DrivesXaXbYZaZbZc4 x ( )434 mm( ) ( )22 mm ( inches)without mm ( inches) mm ( inches)(Ear to PSU surface) ( inches)(Ear to butterfly L brackethousing) mm( inches)(Ear to PSUhandle withoutvelcro strap)8 x ( )434 mm( ) ( )22 mm ( inches)without mm ( inches) mm ( inches)(Ear to PSU surface) mm ( inches)(Ear to butterfly L brackethousing) mm( inches)(Ear to PSUhandle withoutvelcro strap)NOTE: Zb is the nominal rear wall external surface where the system board I/O connectors specifications5 System weightTable 2. PowerEdge R450 system weight System configurationMaximum weight (with all drives/SSDs/bezel)4 x kg ( pound)8 x kg ( pound)Processor specificationsTable 3. PowerEdge R450 processor Specifications Supported processorNumber of processors supported3rd Generation Intel Xeon Scalable processors with up to 24coresUp to twoPSU specificationsThe PowerEdge R450 system supports up to two AC or DC power supply units (PSUs).
3 Table 4. PowerEdge R450 PSU Specifications PSUC lassHeatdissipation(maximum)FrequencyVol tageACDCC urrentHigh line200 240 VLow line100 120 V1100 W DCNA4265 BTU/hrNA-48 (-60) VNANA1100 W27 A800 WMixed ModePlatinum3000 BTU/hr50/60 Hz100 240 VAC,autoranging800 W800 ANA3000 BTU/hrNA240 V DC,autorangingNANA800 A600 WMixed ModePlatinum2250 BTU/hr50/60 Hz100 240 VAC,autoranging600 W600 ANA2250 BTU/hrNA240 V DC,autorangingNANA600 ANOTE: This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding : Heat dissipation is calculated using the PSU wattage : When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the systempower consumption with the Dell Energy Smart Solution Advisor available at operating systemsThe PowerEdge R450 system supports the following operating systems: Canonical Ubuntu Server LTS Citrix Hypervisor6 Technical Specifications Microsoft Windows Server with Hyper-V Red Hat Enterprise Linux SUSE Linux Enterprise Server VMware ESXiFor more information, go to fans specificationsThe PowerEdge R450 system supports Standard (STD) fans, and High performance SLVR fans.
4 NOTE: For more information about the fan support configuration or matrix, see Thermal restriction 5. PowerEdge R450 cooling fan Specifications Fan typeAbbreviationAlso knownasLabelcolorLabel imageStandardfanSTDSTDNo labelFigure 2. Standard fanHighperformance (Silvergrade) fanHPR (SLVR)HPRS ilverNOTE: New cooling fans comes with the High PerformanceSilver Grade label. While the older cooling fans has the HighPerformance specifications7 Table 5. PowerEdge R450 cooling fan Specifications (continued)Fan typeAbbreviationAlso knownasLabelcolorLabel imageFigure 3. High performance (Silver grade) fanSystem battery specificationsThe PowerEdge R450 system supports CR 2032 lithium coin cell system card riser specificationsThe PowerEdge R450 system supports up to two PCI express (PCIe) Gen 4 expansion 6. Expansion card slots supported on the system board PCIe slotRiserPCIe slot heightPCIe slot lengthPCIe slot widthSlot 1 Riser 1 Low ProfileHalf lengthx16 Slot 3 Riser 2cLow ProfileHalf lengthx16 NOTE: For information on the expansion card installation guidelines, see the system specific Installation and ServiceManual available at specificationsThe PowerEdge R450 system supports the following memory Specifications for optimized specificationsTable 7.
5 Memory Specifications DIMM typeDIMM rankDIMM capacitySingle processorDual processorsMinimum DIMM capacityMaximum DIMM capacityMinimumDIMM capacityMaximum DIMM capacityRDIMMS ingle rank8 GB8 GB64 GB16 GB128 GBDual rank16 GB16 GB128 GB32 GB256 GB32 GB32 GB256 GB64 GB512 GB64 GB64 GB512 GB128 GB1 TBTable 8. Memory module sockets Memory module socketsSpeed16, 288-pin2933 MT/s, 2666 MT/sStorage controller specificationsThe PowerEdge R450 system supports the following controller cards:Table 9. PowerEdge R450 storage controller cards Internal controllersExternal controllers PERC H345 PERC H355 PERC H745 PERC H755 HBA355i S150 Boot Optimized Storage Subsystem (BOSS-S1): HWRAID2 x SSDs HBA355e PERC H840 DrivesThe PowerEdge R450 system supports: 4 x Chip SATA (HDD/SSD) drives. 4 x hot-swappable SAS, SATA (HDD/SSD) drives. 8 x SAS, SATA (HDD/SSD) and connectors specificationsUSB ports specificationsTable 10.
6 PowerEdge R450 USB ports Specifications FrontRearInternal (Optional)USB port typeNo. of portsUSB port typeNo. of portsUSB port typeNo. of portsUSB portOneUSB portOneInternal USB portOneTechnical specifications9 Table 10. PowerEdge R450 USB ports Specifications (continued)FrontRearInternal (Optional)USB port typeNo. of portsUSB port typeNo. of portsUSB port typeNo. of portsMicro-USB port foriDRAC DirectOneUSB portOneNOTE: The micro USB compliant port can only be used as an iDRAC Direct or a management port specificationsThe PowerEdge R450 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded onthe LAN on Motherboard (LOM) and integrated on the optional Open Compute Project (OCP) 11. NIC port specification for the system FeatureSpecificationsLOM card1 GbE x 2 OCP card (OCP )1 GbE x 4, 10 GbE x 2, 25 GbE x 2, 25 GbE x 4 Serial connector specificationsThe PowerEdge R450 system supports one optional card type serial connector on rear of the system, which is a 9-pinconnector, Data Terminal Equipment (DTE), 16550-compliant.
7 The process to install the optional serial connector card is similar to an expansion card filler ports specificationsThe PowerEdge R450 system supports two DB-15 VGA ports, one each on the front and rear panels of the PowerEdge R450 system supports Internal Dual SD module (IDSDM).The IDSDM supports two SD cards and is available in the following configurations:Table 12. Supported SD card storage capacity IDSDM card 16 GB 32 GB 64 GBNOTE: One IDSDM card slot is dedicated for : Use Dell EMC branded SD cards that are associated with the IDSDM configured specificationsThe PowerEdge R450 system supports integrated Matrox G200 graphics controller with 16 MB of video frame specificationsTable 13. Supported video resolution options for the system ResolutionRefresh rate (Hz)Color depth (bits)1024 x 768608, 16, 321280 x 800608, 16, 321280 x 1024608, 16, 321360 x 768608, 16, 321440 x 900608, 16, 321600 x 900608, 16, 321600 x 1200608, 16, 321680 x 1050608, 16, 321920 x 1080608, 16, 321920 x 1200608, 16, 32 Environmental specificationsNOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet locatedwith the Documentation > Regulatory Information on 14.
8 Operational climatic range category A2 TemperatureSpecificationsAllowable continuous operationsTemperature ranges for altitudes <= 900 m (<=2953 ft)10 35 C (50 95 F) with no direct sunlight on the equipmentHumidity percent ranges (non-condensing at alltimes)8% RH with -12 C minimum dew point to 80% RH with 21 C ( F)maximum dew pointOperational altitude de-ratingMaximum temperature is reduced by 1 C/300 m ( F/984 Ft) above 900m (2953 Ft)Table 15. Shared requirements across all categories TemperatureSpecificationsAllowable continuous operationsMaximum temperature gradient (applies to bothoperation and non-operation)20 C in an hour* (36 F in an hour) and 5 C in 15 minutes (9 F in 15minutes), 5 C in an hour* (9 F in an hour) for tapeNOTE: * - Per ASHRAE thermal guidelines for tape hardware, these arenot instantaneous rates of temperature temperature limits-40 to 65 C (-40 to 149 F)Non-operational humidity limits5% to 95% RH with 27 C ( F) maximum dew pointMaximum non-operational altitude12,000 meters (39,370 feet)Maximum operational altitude3,048 meters (10,000 feet)Table 16.
9 Maximum vibration Specifications Maximum Grms at 5 Hz to 350 Hz (all operation orientations) G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) Technical specifications11 Table 17. Maximum shock pulse Specifications Maximum shock pulseSpecificationsOperatingSix consecutively executed shock pulses in the positive and negative x, y,and z axis of 6 G for up to 11 msStorageSix consecutively executed shock pulses in the positive and negative x, y,and z axis (one pulse on each side of the system) of 71 G for up to 2 msParticulate and gaseous contamination specificationsThe following table defines the limitations that prevent the damage to the IT equipment and/or, or both failure from particulateand gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results inequipment damage or failure, you must rectify the environmental conditions.
10 Remediation of environmental conditions is theresponsibility of the 18. Particulate contamination Specifications Particulate contaminationSpecificationsAir filtrationData center air filtration as defined by ISO Class 8 per ISO14644-1 with a 95% upper confidence : This condition applies to data center environmentsonly. Air filtration requirements do not apply to ITequipment designed to be used outside a data center, inenvironments such as an office or factory : Air entering the data center must have MERV11 orMERV13 dustAir must be free of conductive dust, zinc whiskers, or otherconductive : This condition applies to data center and non-datacenter dust Air must be free of corrosive dust. Residual dust present in the air must have a deliquescentpoint less than 60% relative : This condition applies to data center and non-datacenter 19. Gaseous contamination Specifications Gaseous contaminationSpecificationsCopper Coupon Corrosion rate<300 /month per Class G1 as defined by Coupon Corrosion rate<200 /month as defined by : Maximum corrosive contaminant levels measured at 50% relative restrictionsTable 20.