Example: biology

MAC 5000 ECG System - Cardio Analytics

GE Medical SystemsInformation TechnologiesMAC 5000 ECG SystemMAC 5000 , GE s premier ECG System , delivers advanced diseasemanagement capabilities through its vast collection of MAC 5000 System offers the sophistication required foradvanced ECG applications, while its ease of use extends this levelof performance to the broadest range of users possible. And it s partof the complete GE suite of networked, non-invasive testingsolutions designed to maximize patient throughput and the stress option, and you combine the industry s leading high-performance resting ECG System with comprehensive, equallyadvanced exercise-testing capabilities in a single, compact on GE s proven performance in ECG analysis: Advanced algorithms set the standard in ECG analysis andinterpretation. Easy-to-use applications and features streamline productivity andworkflow. Seamless connectivity to the MUSE Cardiology InformationSystem speeds data storage and ECG retrieval. Comprehensive training helps maximize your return on with new features that expand your capabilities: Barcode and magnetic card scanning options help reduce patientdata errors.

The MAC 5000 system offers the sophistication required for advanced ECG applications, while its ease of use extends this level of performance to the broadest range of users possible.

Tags:

  System, 5000, Mac 5000 ecg system, Mac 5000 system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MAC 5000 ECG System - Cardio Analytics

1 GE Medical SystemsInformation TechnologiesMAC 5000 ECG SystemMAC 5000 , GE s premier ECG System , delivers advanced diseasemanagement capabilities through its vast collection of MAC 5000 System offers the sophistication required foradvanced ECG applications, while its ease of use extends this levelof performance to the broadest range of users possible. And it s partof the complete GE suite of networked, non-invasive testingsolutions designed to maximize patient throughput and the stress option, and you combine the industry s leading high-performance resting ECG System with comprehensive, equallyadvanced exercise-testing capabilities in a single, compact on GE s proven performance in ECG analysis: Advanced algorithms set the standard in ECG analysis andinterpretation. Easy-to-use applications and features streamline productivity andworkflow. Seamless connectivity to the MUSE Cardiology InformationSystem speeds data storage and ECG retrieval. Comprehensive training helps maximize your return on with new features that expand your capabilities: Barcode and magnetic card scanning options help reduce patientdata errors.

2 New trolley incorporates customer-requested ease-of-use features. XML capabilities ensure flexible, open communications. User-configurable password protection addresses excellence and workflow productivityNon-Invasive CardiologyProduct SheetSetting the mark for clinical validity and excellencein ECG analysisSince the introduction of the Marquette 12SL ECG analysis programin 1980, GE Medical Systems Information Technologies has steadilyexpanded its electrocardiograph-based suite of ECG analysis programsand , we continue to lead developments in computerized ECGanalysis, setting even higher levels of clinical accuracy, validity, andperformance. Through extensive clinical evaluation and the use ofclassic and newly developed ECG interpretation criteria andmeasurement technologies, we steadily refine and improve ourstate-of-the-art suite of ECG analysis programs. Regular clinical input from the world s top consulting cardiologistsand physicians helps our own research and development engineersenhance our programs.

3 Ongoing acquisition of clinically correlated, gold-standard databases allow us to continually evaluate and verify our algorithmperformance. Use of the same patient assessment tests employedby practicing physicians ensures clinically accurate values. Rapid assessments and improvements on very large databases aremade possible by sophisticated analysis techniques, developed byour own engineers, that enable us to quickly evaluate the accuracyof our ECG analysis commitment to improving the science of ECG analysis has ledto the use of our algorithms across GE s diagnostic and implementation makes our programs the preferred choice in avariety of care settings and industries including hospitals, clinics,physician offices, and clinical research organizations (CRO s).A complete suite of analysisalgorithms for advanced ECGapplicationsWith the MAC 5000 s arrhythmia and chestpain assessment tools, you can address awider range of disease management needs,make more efficient decisions, and useinvolved invasive tests more development by one of theindustry s leading algorithm design staffprovides the latest in advanced capabilities,while validation against clinically-verifieddatabases offers unmatched accuracy acrossa diverse range of patient populations, frompediatrics to adults.

4 Marquette 12SL ECG Analysis Programfor Adults and Pediatrics the industry smost thoroughly documented, simultaneous12-lead ECG acquisition analysis programfor uncompromising quality and reliability remains your most clinically valuablesecond opinion. Marquette 12SL with Gender-SpecificInterpretation features criteria that helpyou more easily detect acute myocardialinfarction (MI) in female patients,enhancing diagnostic confidence evenamong occasional readers of ECGs. Marquette 12SL with ACI-TIPI (AcuteCardiac Ischemia Time-InsensitivePredictive Instrument) this optionconsiders a patient s age, gender, and chiefcomplaint as well as ECG measurementsto generate a numerical score that helpspredict the probability of acute cardiacischemia and provides important additionaltriage information for patients with chestpain. Simultaneous 15-Lead Acquisition,Storage, and Assessment provides addi-tional ST measurements for the detectionof changes that occur in some non-diagnostic 12-lead cases to facilitate theprompt detection of right ventricular andposterior MI.

5 P-Wave Signal Averaging option for atrialarrhythmia assessment features a patentedtemplating algorithm that enhancesP-wave measurement accuracy. Hi-Res Late Potential Analysis optionsupports effective ventricular arrhythmiaassessment, with an intuitive design thatcreates a practical, non-invasive alternativeto involved invasive testing. Enhanced Pacemaker-Detection Softwareimproves sensitivity to electronicallypaced hearts. Serial ECG Comparison program, throughthe MUSE Cardiology Information System ,leverages the Marquette 12SL ECGanalysis program and analyzes both short-and long-term changes in patient s to enhance productivity and workflowSpecifically designed to enhance your entire staff s efficiency,the MAC 5000 combines technological advances with ease-of-usefeatures in one System . The digital CAM-14 Module reduces noise and artifact for clearerECG tracings. Large field-of-view display gives you a clear view of the screenfrom any angle. Analog ECG output facilitates easy integration with other cardiac-diagnostic devices, such as echocardiography and nuclearmedicine systems.

6 Compact System design offers easy mobility. Extensive customization including display and final-reportformatting accommodates individual user preferences. Trolley design features a convenient holder for the acquisitionmodule, ample writing surface area, wider bins, and a coveredstorage compartment. The MAC 5000 s stress option incorporates our leadingexercise-testing technologies. Signal-acquisition advanceshelp reduce baseline wander and ST-segmentdistortion to generate clearer, morewell-defined ECGs. Barcode and magnetic card readeroptions help reduce errors by automatingthe input of patient and magnetic card reading optionsComplete connectivity andnetwork access for improvedaccuracy and decision supportTap into the power of GE s MUSE CardiologyInformation System the industry spredominant cardiology management System to take full advantage of your resting ECGpatient information records. Quickly retrieve, manage, and archivepatient data through seamless, bi-directional communication with theMUSE System .

7 Instantly access procedure requests anddownload patient demographic data fromthe MUSE System and Order functionality reduces time-consumingpatient data entry and minimizes delaysin procedure billing. Review results or access the computerECG patient record immediately, any timeof day or night, using the Remote Queryoption for more responsive patient care. Access results from the clinic, office, orother remote facility using a standardmodem for maximum decision-makingefficiency. Export and store data in XML SpecificationsInstrument typeMicroprocessor augmented automatic electrocardio-graph; 14 -leadwire acquisition with programmablelead configurationProcessingECG Interpretation:Marquette 12SL ECG AnalysisProgram for Adults and PediatricsComputerized15-lead analysis includesMeasurements:measurements of user-selectableadditional 3 leadsOptional:Hi-Res Late Potential Analysisand P-Wave Signal AveragedECGA dditional ECGV ectorcardiographyFunction:ECG Analysis500 samples/second (sps)Frequency:ECG Storage:150 typical, 200 ECGsmaximum on removable media( MB, in diskette)15 typical in XML formatDigital Sampling Rate: 4000 samples/second/channelPre-Acquisition:Pr ovides 10 seconds ofinstantaneous ECG acquisitionDynamic Range:AC Differential 5 mVDC offset 320 V/LSB @ 250 V/LSB @ 500 spsFrequency Response: 3 dB @ to 150 HzCommon Mode>140 dB (123 dB withRejection:AC filter disabled)Input Impedance:>10M @ 10 Hz,defibrillator protectedPatient Leakage:<10 APace Detect:Orthogonal LA, LL, andV6.

8 750 V @ 50 sSpecial AcquisitionDisconnected leadFunctions:detection, electrode impedance,excessive AC noise, baselinewander and muscle tremormessagesHeart Rate Meter:30 to 300 BPM 10% or 5 BPM,whichever is greater. Heart ratesoutside this range will not Cardiology Information System compatibleOptional:Modem and Fax transmission,Remote Retrieval (RemoteQuery)Performance Specifications (cont.)DisplayDisplay in (264 mm) diagonalgraphics backlit AM LCD(color optional)Display Resolution:640 x 480 pixels with waveformenhancementDisplay Data:Heart rate, patient name, ID,clock, waveforms, lead labels,speed, gain and filter settings,warning messages, prompts, andhelp messagesWriterWriter Technology:Thermal dot arrayWriter Speeds:5, , 25, & 50 mm/s(same as displayed)Number of Traces:3, 6, 12, or 15, user-selectable(same as displayed)Writer Sensitivity/Gain: , 5, 10, 20, 10/5 (splitcalibration) mm/mV(same as displayed)Writer Speed Accuracy: 2%Writer Amplitude 5%Accuracy:Writer Resolution:Horizontal 1000 dpi @25 mm/s, 200 dpi verticalPaper Type:Thermal, Z-fold, perforated,fan fold, 300 sheets/packPaper Size:A in x 11 in( mm x 280 mm)A4 in x in(210 mm x mm)KeyboardType:Sealed elastomer with softfunction keys, alphanumerickeys, writer controls, andTrimPad cursor controlsElectricalPower Supply:AC or battery operationVoltage.

9 100 to 240 VAC +10, 15% @ 115 VAC, @ 240 VAC, typicalFrequency:50 to 60 Hz 10%Battery Type:User replaceable, 18V AH 10% rechargeableNiMHBattery Capacity:100 single page reports(typical) or 6 hours continuousdisplay (without printing)Battery Charge Time: Approximately hoursfrom total discharge(with display off)Performance SpecificationsVectorcardiographyReport Formats:Vector loops of componentvectors (P, QRS, ST-T)Sensitivity:20, 40, 80, or 160 mm/mVTime Resolution:2 msHi-Res Late Potential Analysis and P-Wave Signal Averaged ECGF requency 3 dB @ andResponse/Input:250 HzFrequencyResponse/Output: Upper Limit:250 Hz Lower , 25, 40, or 80 HzSensitivities: Raw Data Template: 20 mm/mV Average Beat:20 mm/mV and 50 mm/mVFiltered Signals and 1 mm/ VVector Magnitude:Analysis Sampling1000 samples/Rate:second/channelDigital Sampling4000 samples/Rate:second/channelHigh/Low Pass Filters: Special filter usingFast Fourier Transform (FFT)ADC V/LSBA nalysis Resolution: V/LSBP hysical in ( cm)* withdisplay closedWidth:15 in ( cm)* in ( cm)*Weight:Approximately kg(15 lbs)* including batterywithout paperEnvironmental SpecificationsTemperature:Operating:50 to 104 F (10 to 40 C)Transport/Storage: 40 to 158 F ( 40 to 70 C)Humidity:Operating:20% to 95% RH non-condensingTransport/Storage:15% to 95% RHnon-condensingPressure:Operating:700 to 1060 hPATransport/Storage:500 to 1060 hPA* without cartTrolleySpecificationsDimensions: Height:39 in (99 cm) Width:21 in (54 cm) Depth:28 in (72 cm)Temperature in (134 cm)acquisition moduleholderWeight:55 lbs (25 kg)Magnetic Card ReaderSpecificationsCharacter SetANSI/ISO ALPHA alphanumericcharacters and ANSI/ISOBCD (subset of ASCII (ISO646 IRV:1991))Dimensions: in (28 mm) in (100 mm) in (34 mm)Temperature Range50 F to 104 FOperating:(-10 C to 40 C)Humidity.

10 10% to 90% humidityAgency Conformance: Complies with FCC Class :The System has been testedto and conforms with theprovisions within 89/336/EEC,Electromagnetic Compatibilitydirective (EMC)Keyboard Wedge/DecoderSpecificationsDimensions: in ( cm) in ( cm) in ( cm)Electrical:Complies with UL, CSA,and VDET emperature Ranges: Operating:32 F to 104 F (0 C to 40 C) Storage:40 F to 158 F (-40 C to 70 C)Humidity:0% to 95% non-condensingMechanical Shock:Functions normally aftertwelve 6ft.( cm) dropsonto a concrete surfaceEMI Radiation:FCC Class A and **EN55022 Class B (1988)ESD Sensitivity:Meets **IEC 801-2: 1991/1984and a minimum of 300discharges at intervalsfrom to Susceptibility:Meets **IEC 801-3; 1984 Electrical FastMeets **IEC 801-4; 1988 Transients:**These requirements combined with EN50082-1; 1992indicate conformity to the EMC directive 89/336/EECE uropean HeadquartersGE Medical Systems Information Technologies Box 60 02 65 79032 Freiburg, GermanyTel.