Example: stock market

MATERIAL SAFETY DATA SHEET - Cranesville Block

MATERIAL SAFETY data SHEETQUAKER STATE dexron III/MERCON automatic TRANSMISSION FLUID1. PRODUCT AND COMPANY IDENTIFICATIONMSDS Number: 14957 Version Date: 07/17/00 Product Name: QUAKER STATE dexron III/MERCON automatic TRANSMISSION FLUIDP roduct Use: No information availableSynonyms: No information available ManufacturerPennzoil-Quaker State 2967 Houston, TX 77252 USAP hone NumbersMedical Emergency: 1-800-546-6040 CHEMTREC(USA): 1-800-424-9300 CHEMTREC(International): 1-703-527-3887 MSDS Assistance: 1-800-546-6227 Fax On Demand: 1-800-546-6227 Technical Assistance: 1-800-458-4998 Customer Service: 1-800-468-8397 Fax Number.

MATERIAL SAFETY DATA SHEET MSDS Number: 14957 QUAKER STATE DEXRON III/MERCON AUTOMATIC TRANSMISSION FLUID Page 3 of 7 Unusual Fire and Explosion Conditions: Dense smoke may be generated while burning. Carbon monoxide, carbon dioxide, and other oxides may be generated as products of combustion.

Tags:

  Sheet, Data, Fluid, Safety, Material, Automatic, Transmissions, Material safety data sheet, Dexron, Automatic transmission fluid, Dexron iii

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MATERIAL SAFETY DATA SHEET - Cranesville Block

1 MATERIAL SAFETY data SHEETQUAKER STATE dexron III/MERCON automatic TRANSMISSION FLUID1. PRODUCT AND COMPANY IDENTIFICATIONMSDS Number: 14957 Version Date: 07/17/00 Product Name: QUAKER STATE dexron III/MERCON automatic TRANSMISSION FLUIDP roduct Use: No information availableSynonyms: No information available ManufacturerPennzoil-Quaker State 2967 Houston, TX 77252 USAP hone NumbersMedical Emergency: 1-800-546-6040 CHEMTREC(USA): 1-800-424-9300 CHEMTREC(International): 1-703-527-3887 MSDS Assistance: 1-800-546-6227 Fax On Demand: 1-800-546-6227 Technical Assistance: 1-800-458-4998 Customer Service: 1-800-468-8397 Fax Number.

2 713-217-3181 Internet Address: COMPONENT INFORMATIONC omponentCAS PercentRangeHazardousin BlendLIGHT PARAFFINIC SOLVENT DEWAXEDDISTILLATE64742-56-9< 90 NoHYDROTREATED LIGHT PARAFFINICDISTILLATE64742-55-8< 90 NoHYDROTREATED HEAVY PARAFFINICDISTILLATE64742-54-7< 90 NoHEAVY PARAFFINIC SOLVENT DEWAXEDDISTILLATE64742-65-0< 90 NoSOLVENT REFINED LIGHT NAPHTHENICPETROLEUM DISTILLATE64741-97-5< 90 NoDETERGENT/INHIBITOR SYSTEMMIXTURE10 - 15 NoDYEMIXTURE< 1 NoThis product is NOT HAZARDOUS according to OSHA 29 CFR : No information available_____3. HAZARDS IDENTIFICATIONE mergency and Hazards OverviewCAUTION: Repeated skin contact can cause dermatitis and defatting of the skin.

3 Spills may create aslipping hazard. NFPA Ratings:Health1 Flammability1 Reactivity0 Primary Route of Exposure:SkinXInhalationEyeHealth Effect InformationEye Contact: This product is practically non-irritating to the eyes upon direct contact. Based on testingof similar products and/or SAFETY data SHEETMSDS Number: 14957 QUAKER STATE dexron III/MERCON AUTOMATICTRANSMISSION FLUIDPage 2 of 7 Skin Contact: Avoid skin contact. This product may cause slight skin irritation upon direct on testing of similar products and/or components. Prolonged or repeated contact may resultin contact dermatitis which is characterized by dryness, chapping, and reddening.

4 Prolonged orrepeated contact may result in oil acne which is characterized by blackheads with possiblesecondary infection. See Section 11 - Toxicological : This product has a low vapor pressure and is not expected to present an inhalation hazard atambient conditions. Caution should be taken to prevent aerosolization or misting of this permissible exposure limit (PEL) and threshold limit value (TLV) for this product as oil mistis 5 mg/m3. Exposures below 5 mg/m3 appear to be without significant health risk. The short-termexposure limit for this product as an oil mist is 10 : Do not ingest.

5 This product is relatively non-toxic by ingestion. This product has laxativeproperties and may result in abdominal cramps and diarrhea. See Section 11 - Conditions Aggravated by Exposure: This condition may make the skin more susceptible toother irritants, sensitizers, and : No information available_____4. FIRST AID INFORMATIONEye Contact: Immediately flush eyes with large amounts of water and continue flushing until irritationsubsides. If MATERIAL is hot, treat for thermal burns and seek immediate medical attention. Skin Contact: Remove contaminated clothing.

6 Wash contaminated area thoroughly with soap and water. Ifredness or irritation occurs, seek medical attention. If MATERIAL is hot, submerge injured area incold water. If victim is severely burned, remove to a hospital : This MATERIAL has a low vapor pressure and is not expected to present an inhalation exposure atambient : Do not induce vomiting. Seek medical to Physician: No information availableOther: No information available_____5. FIRE AND EXPLOSION INFORMATIONF lammable PropertiesFlash Point: F, 177 CTest Method: ASTM D-92 ( )Flammable Limits in Air Upper Percent: No data available Lower Percent: No data availableAutoignition Temperature: No data availableTest Method: No information availableNFPA Classification: No information availableExtinguishing Media: Use dry chemical, foam, or carbon dioxide.

7 Fire Fighting Measures Special Fire Fighting Procedures and Equipment: Water may be ineffective but can be used to coolcontainers exposed to heat or flame. Caution should be exercised when using water or foam asfrothing may occur, especially if sprayed into containers of hot, burning SAFETY data SHEETMSDS Number: 14957 QUAKER STATE dexron III/MERCON AUTOMATICTRANSMISSION FLUIDPage 3 of 7 Unusual Fire and Explosion Conditions: Dense smoke may be generated while burning. Carbonmonoxide, carbon dioxide, and other oxides may be generated as products of combustion.

8 Hazardous Combustion By-Products: No information availableOther: No information available_____6. ACCIDENTAL RELEASE MEASURESP ersonnel Safeguards: Consult Health Effect Information in Section 3, Personal Protection Information inSection 8, Fire and Explosion Information in Section 5, and Stability and Reactivity Informationin Section 10. Remove all sources of Notifications: No information availableContainment and Clean up: No information availableOther: No information available_____7. HANDLING AND STORAGE INFORMATIONH andling: Fire extinguishers should be kept readily available.

9 See NFPA 30 and OSHA and Combustible : Do not transfer to unmarked containers. Store in closed containers away from heat, sparks, openflame, or oxidizing Container Warnings Drums: No information available Plastic: No information availableOther: No information available_____8. EXPOSURE CONTROLS / PERSONAL PROTECTION INFORMATIONE xposure Limits and GuidelinesThis product does not contain any components with OSHA or ACGIH exposure Protective Equipment Eye/Face Protection: Eye protection is not required under conditions of normal use. If MATERIAL ishandled such that it could be splashed into eyes, wear plastic face shield or splash-proof safetygoggles.

10 Skin Protection: No skin protection is required for single, short duration exposures. For prolonged orrepeated exposures, use impervious clothing (boots, gloves, aprons, etc.) over parts of the bodysubject to exposure. If handling hot MATERIAL , use insulated protective clothing (boots, gloves,aprons, etc.). Launder soiled clothes. Properly dispose of contaminated leather articles includingshoes, which cannot be decontaminated. Respiratory Protection: Respiratory protection is not required under conditions of normal use. If vaporor mist is generated when the MATERIAL is heated or handled, use an organic vapor respirator with adust and mist filter.


Related search queries