Example: air traffic controller

Maxiflow Series - filter selector

8585 Parker HannifinHydraulic filter Division for both suction and return applicationSpin-on filtersThe Maxiflow Series full flow filters for suction or return are designed to provide quality protection for hydraulic or lubrication at a maximum pressure of 10 bar at 360 l/min, Maxiflow filters cover a wide range of mobile and industrial Features: Maxiflow full flow filters for suction or return applications. Available with optional indicators. Maximum pressure 10 bar. Maximum flow 360 l/min. High quality filter Information:Parker Hannifin Hydraulic filter Division EuropeEuropean ProductInformation CentreFreephone: 00800 27 27 5374(from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, Series Spin-on FiltersMax. 360 I/min - 10 barParker HannifinHydraulic filter Division EuropeFDHB500UK/MaxiflowTypical Applications Telescopic handlers Refuse vehicles Road sweepers Compactors Industrial power units Grass cutters Press brakesThe Parker Filtration Maxiflow Full Flow Filters for Suction or filters are ideally suited to full flow and bypass circuit installations where the need for high quality filter media is recommended for effective protection of system components, improving system productivity a)

88 Parker annifin ydraulic Filter Division urope FDB. Spin-on Filters Maxiflow Series Pressure Drop Curves Filter Housing Maxiflow MXA 1 Series 0 0.2 0.4

Tags:

  Series, Curves, Maxiflow series, Maxiflow

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Maxiflow Series - filter selector

1 8585 Parker HannifinHydraulic filter Division for both suction and return applicationSpin-on filtersThe Maxiflow Series full flow filters for suction or return are designed to provide quality protection for hydraulic or lubrication at a maximum pressure of 10 bar at 360 l/min, Maxiflow filters cover a wide range of mobile and industrial Features: Maxiflow full flow filters for suction or return applications. Available with optional indicators. Maximum pressure 10 bar. Maximum flow 360 l/min. High quality filter Information:Parker Hannifin Hydraulic filter Division EuropeEuropean ProductInformation CentreFreephone: 00800 27 27 5374(from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, Series Spin-on FiltersMax. 360 I/min - 10 barParker HannifinHydraulic filter Division EuropeFDHB500UK/MaxiflowTypical Applications Telescopic handlers Refuse vehicles Road sweepers Compactors Industrial power units Grass cutters Press brakesThe Parker Filtration Maxiflow Full Flow Filters for Suction or filters are ideally suited to full flow and bypass circuit installations where the need for high quality filter media is recommended for effective protection of system components.)

2 Improving system productivity and indicators provide direct information as to when the spin-on canisters require & BenefitsFeaturesHigh quality paint for canistersSpin-on filters available for suction and return line filtrationHigh quality filter mediumAdvantagesLong term protection against corrosionFlexible product offering filter medium suitable for fatigue load due to high frequent flow fluctuationBenefitsBetter protection against environmental influencesStandardisation of components Extended element life timeMaxiflow Series Spin-on FiltersMax. 360 I/min - 10 bar86 Parker HannifinHydraulic filter Division EuropeFDHB500UK/MaxiflowMXA 3 SeriesMXA 2 SeriesMXA 1 SeriesInstallation DetailsSpecification MXA SeriesMaximum working pressure: 10 barFilter head material: Aluminium alloyFilter bowl material: SteelSeal material: NitrileOperating temperature range: -30 C to +100 CBypass: Return line bar Suction line bar No bypass optionFluids: Mineral oilsElement media.

3 Microglass III media Cellulose mediaMXA 1 Series MXA 2 Series MXA 3 Series 8687 Parker HannifinHydraulic filter Division EuropeFDHB500UK/Maxiflow43070 128,514572M10 (2x)65956037M6 (2x)381423,544,516,7194 9622 128,524722,13516M8 (2x)501335295663088 Parker HannifinHydraulic filter Division FiltersMaxiflow SeriesPressure Drop CurvesFilter HousingMaxiflow MXA 1 (l/min) p (bar)Flow (US GPM)03811165131821242629 p (PSID) (l/min) p (bar)Flow (US GPM)10 Abs10 Nom0381116315131821242629 p (PSID) ElementFilter HousingMaxiflow MXA 2 p (bar)080200220240180160140120100204060 Flow (l/min)Flow (US GPM)0516213111263742475358 p (PSID) (l/min) @32 cStdelta p (bar)3 110 ElementFilter HousingMaxiflow MXA 3 p (bar) (l/min)Flow (US GPM)026531339667992 p (PSID) (l/min) p (bar)10 AbsFlow (US GPM)013263953667992 p (PSID) NomFilter ElementThe recommended level of the initial pressure drop for low pressure filters is max the medium used has a viscosity different from 30cSt, pressure drop over the filter can be estimated as follows:Dp = (Dp30 x viscosity of medium used) / 30cSt.

4 Note: All above data is calculated at 30cSt Rel density HannifinHydraulic filter Division EuropeFDHB500UK/Maxiflow8889 Parker HannifinHydraulic filter Division HannifinHydraulic filter Division EuropeFDHB500UK/Maxiflow88 Indicator SpecificationsOptionIndicator PS NO/NC Pressure SwitchCode S2/S3G1/8 (BSP) 289 Protective cover24 typeCode42V / 2AG1/8 AMP terminal (terminal IP00)NO or NCFMUS2 EBMG02L (NO switch)FMUS3 EBMG02L (NC switch)SpecificationsNormally open contactsNormally closed contactsBox 1 Housing typeCodeMXA1 MXA1 MXA2 MXA2 MXA3 Double element versionMXA3 Box 2 Element LengthDimensionsThread Spin-on canCodeShort (MXA 1 only)D= L= G3/4"On requestSize 1 (MXA 1 only)D= L=145G3/4"2 Size 2 (Not for MXA1)D= L=180G1 "3 Ext'd Size 2 (Not for MXA1)D= L=226G1 "On requestBox 3 filter MediaCode10 micron Microglass III micron (nom) Cellulose10C3 micron Abs.

5 (MXA2 + 3 only)03 QBox 4 Seal MaterialCodeNitrileBBox 5 IndicatorCodePlugged portPPressure Switch 42V, bar setting, NOS2 Pressure Switch 42V, bar setting, NCS3 Pressure Gauge, setting barG2 Box 6 Bypass barGBlocked bar SuctionOn requestBox 7 PortsCodeG3/4" (MXA1 only)G12G1 (MXA2 only)G20G1 (MXA3 only)G24 Box 8 Housing typeCodeStandard1 Ordering InformationOptionVisual Pressure IndicatorCode G2 Thread connection G1/8 Code FMUG2 EBPG02 LVisual indicator