Example: tourism industry

Meeting Elevator Disconnect Requirements Has …

Meeting Elevator DisconnectRequirements Has never Been EasierThe Cooper Bussmann Quik-Spec power module Switches and PanelsOffer the Superior All-In-One Solution Easy-to-SpecifyNo need to worry if you re Meeting Code Requirements . TheCooper Bussmann Quik-Spec power module Switchbuild-a-code assures you get all the right components, withthe right ratings, properly Data Sheet 1145* for more details. Easy-to-InstallThe Quik-Spec power module Switch comes as a completely assembled unit for quick installation. This all-in-one solution reduces the labor and time needed toassemble individual components.

Meeting Elevator Disconnect Requirements Has Never Been Easier The Cooper Bussmann® Quik-Spec™ Power Module™ Switches and Panels Offer the Superior All …

Tags:

  Requirements, Power, Meeting, Never, Module, Elevator, Disconnect, Power module, Meeting elevator disconnect requirements has, Meeting elevator disconnect requirements has never

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Meeting Elevator Disconnect Requirements Has …

1 Meeting Elevator DisconnectRequirements Has never Been EasierThe Cooper Bussmann Quik-Spec power module Switches and PanelsOffer the Superior All-In-One Solution Easy-to-SpecifyNo need to worry if you re Meeting Code Requirements . TheCooper Bussmann Quik-Spec power module Switchbuild-a-code assures you get all the right components, withthe right ratings, properly Data Sheet 1145* for more details. Easy-to-InstallThe Quik-Spec power module Switch comes as a completely assembled unit for quick installation. This all-in-one solution reduces the labor and time needed toassemble individual components.

2 Provides Easy Selective CoordinationTo meet this Code and end-user requirement, the Quik-SpecPower module Switch utilizes Cooper Bussmann Low-Peak Class J fuses that easily coordinate with anyupstream Low-Peak fuse by simply using a 2:1 lineside-to-loadside fuse ratio. UL 98 ListedThe Quik-Spec power module Switch meets prevailingANSI/ASME, NEC and NFPA 72 Requirements in a UL 98 Listed (enclosed switch) and UL 50 Listed (enclosure) unit. Quik-Spec power module Panel for Multi- Elevator ApplicationsFeaturing multiple switches in a single panel, the Quik-SpecPower module Panel offers significant space savings.

3 Likethe switch, the Quik-Spec power module Panel is easy tospecify and factory configured to meet prevailingANSI/ASME, NEC and NFPA 72 Requirements for UL 98 Enclosed and Dead-Front order, just call your Cooper Bussmann representative with all relevant electrical and circuit information, and we do the Data Sheet 1146* for more details.* Data Sheets online at AvailableWithQuik-ShipService Switches ship within 3 business days Panels ship within 10 business days See back page for details 2009 Cooper BussmannSt. Louis, MO # 3136 0809-5 MPrinted in USAThe Quik-Spec power module Switch and Panel are the best choices fordesign engineers and electrical contractors that need to meet theserequirements, Codes and standards: Elevator Shutdown ANSI/ASME , NEC (B) ( Elevator Shutdown) NEC (Orderly Shutdown) Shunt Trip Voltage Monitoring NFPA 72, Selective Coordination NEC Auxiliary Contact (Hydraulic Elevator ) NEC (C)Both Quik-Spec power module Switches and Panels provide.

4 Shunt trip capability Selective coordination Fire safety signal interface Shunt trip voltage monitoring Component protection via Cooper Bussmann Low-Peak Class Jfuses UL 98 Listed for 200kA short-circuit current rating Lockable in the open position with three lock capability Optional key-test switch and optional pilot light for easy inspection No annual calibration or testing of overcurrent protection required Padlockable for service work safety and open door override for troubleshootingNNoottee::Always follow established safety practices when working on a electrically live and Install the Quik-Spec power module with ConfidenceQuik-Spec power module Switch Catalog Numbering SystemUse the following build-a-code to specify the exact Quik-Spec power module Switch you need for your * 100VA with Primary and Secondary fusing (120V Secondary) ** For use only with R1 optionThe Quik-Spec power ModuleSwitch (PS) for single elevatorapplicationsQuik-Spec power module Panel(PMP)

5 For multiple Elevator applicationsPrefixPS = PowerModule SwitchAmp Rating3 = 30A6 = 60A1 = 100A2 = 200A4 = 400 AControlTransformer*T20 = 208VT24 = 240VT48 = 480VT60 = 600 VFire Safety Interface Relay (3 PDT, 10A, 12V)R1 = 120 Vac CoilR2 = 24 Vdc CoilKey Test Switch(Optional)K = KeyPilot Light ON(Optional)G = GreenR = RedW = WhiteNeutral Lug(Optional)N6 = 30-60AN1 = 100AN2 = 200AN4 = 400 AAuxiliaryContactsB = 2 NO/NCFire Alarm VoltageMonitoring Relay(Optional)To Monitor ShuntTrip VoltageF1 = Single-PoleF3 = Three-Pole**Enclosure Options(TYPE 1 Standard - No Suffix DesignationRequired)U = Type 3RZ = Type 12Y = Type 4 Quik-Ship Program: Switch - 3 Days, Panel - 10 Days!

6 Ship-direct service within three business days for power module Switches (PS_) and 10 business days for power module Panels (PMP_).* Three day PS_ shipment requires ordering from catalog numbers shown.** 10 Day PMP_ shipment covers NEMA 1 enclosures with the ampacities shown and all Requirements for relay type (AC or DC), accessory options and number of switches. To order PMP_, contact your Cooper Bussmann representative with all relevant electrical and circuit information, we do the module Switch* power module Panel**Cat NumbersAmpsVoltsCat. Numbers AmpsPS6T48R1 KGBF3-X60A480 VPMP-400-X400 APS1T48R1 KGBF3-X100A480 VPMP-600-X600 APS1T20R1 KGBF3-X100A208 VPMP-800-X800 APS2T48R1 KGBF3-X200A480 VPS2T20R1 KGBF3-X200A208V