Example: tourism industry

Micro Motion ELITE Mass Flow and Density Meters

Product Data SheetPS-00374, Rev. FJune 2006 Micro Motion ELITE mass Flow and Density MetersWith MVD Technology Unsurpassed performance: mass flow accuracy to of rate, and Density accuracy to g/cm3 ( kg/m3) For mass and volume flow measurement of both gases and liquids Wide range of sizes from 1/10 to 6 (3 mm to 150 mm) Now available with Micro Motion s newest transmitter, the Model 2400S2 Micro Motion ELITE Flow and Density MetersMicro Motion ELITE mass flow and Density metersMicro Motion ELITE Meters are the leading Meters for precision flow and Density measurement.

Micro Motion® ELITE® Flow and Density Meters 3 Liquid flow performance Mass Volume(1) (1) Specifications for volumetric flow rate are based on a process-fluid density of 1 g/cm 3 (1000 kg/m3).

Tags:

  Micro, Flows, Mass, Meters, Motion, Density, Elite, Micro motion, Flow and density meters, Micro motion elite mass flow and density meters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Micro Motion ELITE Mass Flow and Density Meters

1 Product Data SheetPS-00374, Rev. FJune 2006 Micro Motion ELITE mass Flow and Density MetersWith MVD Technology Unsurpassed performance: mass flow accuracy to of rate, and Density accuracy to g/cm3 ( kg/m3) For mass and volume flow measurement of both gases and liquids Wide range of sizes from 1/10 to 6 (3 mm to 150 mm) Now available with Micro Motion s newest transmitter, the Model 2400S2 Micro Motion ELITE Flow and Density MetersMicro Motion ELITE mass flow and Density metersMicro Motion ELITE Meters are the leading Meters for precision flow and Density measurement.

2 ELITE Meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop. Every ELITE meter features standard secondary containment, and is available with stainless steel or nickel alloy wetted parts and a wide variety of process connections to meet your every need. ELITE Meters have been designed for special applications. The CMF010 provides remarkably high performance in low-flow applications. The high-pressure CMF010P is suitable for applications up to 6000 psi (413 bar). The Model CMF400 meter offers the most accurate measurement available in a high-capacity meter.

3 Models CMF200, CMF300, and CMF400 are available in high-temperature and extreme high-temperature versions that provide accurate measurements in severe environments up to 800 F (427 C).Product selector programMicro Motion offers an on-line program for finding the best products to fit your application. The product selector program allows you to specify the parameters that matter to you, such as accuracy, flow capacity, pressure drop, or turndown. To use the product selector program, visit our web site at flow performance .. 3 Gas flow performance .. 5 Density performance (liquid only).

4 8 Power consumption .. 8 Vibration limits .. 8 Temperature specifications .. 9 Pressure ratings .. 11 Environmental effects .. 12 Hazardous area classifications .. 13 Materials of construction .. 21 Weight .. 21 Dimensions .. 22 Fitting options .. 40 Ordering information .. 47 Micro Motion ELITE Flow and Density Meters3 Liquid flow performance MassVolume(1)(1) Specifications for volumetric flow rate are based on a process-fluid Density of 1 g/cm3 (1000 kg/m3). For fluids with Density other than 1 g/cm3 (1000 kg/m3), the volumetric flow rate equals the mass flow rate divided by the fluid s flow ,20012027,200 CMF200320087,10038587,10055087 CMF30010,000272,0001200272,0001700272 CMF40020,000545,0002400545,0003400545 mass and volume flow accuracy(2)(3)(2) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis.

5 All specifications for liquids are based on reference conditions of water at 68 to 77 F (20 to 25 C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.(3) The calibration option for flow accuracy is not available with high-temperature sensor models or Model 2400S transmitter or enhanced core processor of rate(4)(5)(4) When flow rate is less than zero stability / , accuracy = [(zero stability / flow rate) 100]% of rate, and repeatability = [ (zero stability / flow rate) 100]%(5) When ordered with the factory calibration option, accuracy on liquid = when flow rate zero stability / When flow rate < zero stability / , accuracy equals [(zero stability / flow rate)]

6 100]% of rate andrepeatability equals [ (zero stability / flow rate) 100]% of with MVD Technology of rate(6)(6) When flow rate is less than zero stability / , accuracy equals [(zero stability / flow rate) 100]% of rate andrepeatability equals [ (zero stability / flow rate) 100]% of other transmitters [(zero stability / flow rate) 100]% of rateMass and volume flow repeatabilityModel 2400S transmitter or enhanced core processor of rate(4) (5)Transmitter with MVD Technology of rate(6)All other transmitters [ (zero stability / flow rate) 100]% of ratelb/minkg/hZero Motion ELITE Flow and Density MetersLiquid flow performance continued Typical accuracy, turndown, and pressure drop with CMF100 and 2400S transmitter or enhanced core processorThe graph below is an example of the relationship between accuracy, turndown, and pressure drop when measuring the flow of water with a Model CMF100 sensor and Model 2400S transmitter or enhanced core processor.

7 Actual pressure drop is dependent on process conditions. To determine accuracy, turndown, and pressure drop with your process variables, use Micro Motion s product selector, available at r n d ow n f ro m maximum flow rate500:1100:120:110:12:1 Accuracy ( %) droppsi~0~ ~0~ rate, % of maximumAccuracy, % :120:11:12:110:1 Micro Motion ELITE Flow and Density Meters5 Gas flow performance When selecting sensors for gas applications, measurement accuracy is a function of fluid mass flow rate independent of operating temperature, pressure, or composition.

8 However, pressure drop through the sensor is dependent upon operating temperature, pressure, and fluid composition. Therefore, when selecting a sensor for any particular gas application, it is highly recommended that each sensor be sized using Micro Motion s product selector, available at (1)(1) Standard (SCFM) reference conditions are psia and 68 F. Normal (Nm3/h) reference conditions are bar and 0 rates that produce approximately 10 psid ( bar) pressure drop on air at 68 F (20 C) and 100 psi ( bar)CMF010M, ,300650010,300 CMF400125034,00016,60026,250 Flow rates that produce approximately 50 psid ( bar) pressure drop on natural gas (MW ) at 68 F (20 C) and 500 psi ( bar)CMF010M, ,20013,00020,500 CMF300185050,50043,00068,000 CMF4004700128,000109,000172,0006 Micro Motion ELITE Flow and Density MetersGas flow performance continued mass flow accuracy(1)(1)

9 Flow accuracy includes the combined effects of repeatability, linearity, and with MVD Technology (including Model 2400S) of rate(2)(2) When flow rate is less than zero stability / , accuracy equals [(zero stability / flow rate) 100]% of rate and repeatability equals [ (zero stability / flow rate) 100]% of other transmitters of rate of rateMass flow repeatabilityTransmitters with MVD Technology (including Model 2400S) of rate(2)All other transmitters of rate of ratelb/minkg/hZero zero stabilityflow rate--------------------------------- 100 % zero stabilityflow rate--------------------------------- 100 % Micro Motion ELITE Flow and Density Meters7 Gas flow performance continued Typical mass flow accuracy and pressure drop with CMF100 and transmitter with MVD TechnologyAir at 68 F (20 C), static pressures as indicated on graphNatural gas (MW ) at 68 F (20 C)

10 , static pressure as indicated on graphStandard or Normal Volumetric CapabilityStandard and normal volumes are quasi mass flow units for any fixed composition fluid. Standard and normal volumes do not vary with operating pressure, temperature, or Density . With knowledge of Density at standard or normal conditions (available from reference sources), a Micro Motion meter can be configured to output in standard or normal volume units without the need for pressure, temperature, or Density compensation. Contact your local sales representative for more ratePressure dropAccuracy ( % of rate)02040608010012014016000100020003000 4000lb/ psig(7 bar)500 psig(35 bar)1000 psig(70 bar) ratePressure dropAccuracy ( % of rate)02040608010012014016000100020003000 4000lb/ psig(7 bar)500 psig(35 bar)1000 psig(70 bar)8 Micro Motion ELITE Flow and Density MetersDensity performance (liquid only) Power consumption Vibration limits With 2400S transmitter or enhanced core processorWith transmitter with MVD Technology (except Model 2400S)


Related search queries