Example: stock market

Micropilot FMR51, FMR52 Technical Information - …

Level measurement in liquidsApplication Continuous, non-contact level measurement of liquids, pastes and slurries Horn antenna (FMR51); flush mounted, completely filled PTFE horn antenna( FMR52 ) Maximum measuring range: 70 m (230 ft) Temperature: 196 to +450 C ( 321 to +842 F) Pressure: 1 to +160 bar ( to +2 320 psi) Accuracy: 2 mm International explosion protection certificates; WHG; marine approvals Linearity protocol (3-point, 5-point)Your benefits Reliable measurement even for changing product and process conditions HistoROM data management for easy commissioning, maintenance anddiagnostics Highest reliability due to Multi-Echo Tracking SIL2 according to IEC 61508, SIL3 in case of homogeneous or heterogeneousredundancy Seamless integration into control or asset management systems Intuitive user interface in national languages Easy proof test for SIL and WHGP roductsSolutionsServicesTechnical InformationMicropilot FMR51, FMR52 Free space radarTI01040F/00/ FMR51, FMR522 Endress+HauserTable of contentsImportant

6 Endress+Hauser Function and system design Measuring principle The Micropilot is a "downward-looking" measuring system, operating based on the time-of-flight method (ToF). It measures the distance from the reference point (process connection) to the product surface. Radar impulses are emitted by an antenna, reflected off the product surface ...

Tags:

  Sender

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Micropilot FMR51, FMR52 Technical Information - …

1 Level measurement in liquidsApplication Continuous, non-contact level measurement of liquids, pastes and slurries Horn antenna (FMR51); flush mounted, completely filled PTFE horn antenna( FMR52 ) Maximum measuring range: 70 m (230 ft) Temperature: 196 to +450 C ( 321 to +842 F) Pressure: 1 to +160 bar ( to +2 320 psi) Accuracy: 2 mm International explosion protection certificates; WHG; marine approvals Linearity protocol (3-point, 5-point)Your benefits Reliable measurement even for changing product and process conditions HistoROM data management for easy commissioning, maintenance anddiagnostics Highest reliability due to Multi-Echo Tracking SIL2 according to IEC 61508, SIL3 in case of homogeneous or heterogeneousredundancy Seamless integration into control or asset management systems Intuitive user interface in national languages Easy proof test for SIL and WHGP roductsSolutionsServicesTechnical InformationMicropilot FMR51, FMR52 Free space radarTI01040F/00/ FMR51, FMR522 Endress+HauserTable of contentsImportant document and system on plug supply entries.

2 31 Cable operating measured value of ambient of gas phase compensation with external pressure sensor(PROFIBUS PA, FOUNDATION Fieldbus).. cladded in vessel (free space)..41 Installation in stilling in with heat temperature temperature according to IEC61010-1 of the compatibility (EMC).. temperature, Process : GT18 : GT19 : GT20 : Antenna and process : Weather protection with remote display and operating in tank gauging integration via and seal according to ANSI/ISA MR 0175 / ISO MR Equipment certificate (in preparation)..88 Radio standard EN302729-1 standard EN302372-1 / Industry radio , standards and guidelines.

3 92 Ordering linearity linearity FMR51, FMR52 Endress+Hauser3 Communication-specific Instructions (XA)..103 Registered FMR51, FMR524 Endress+HauserImportant document informationSymbolsSafety symbolsSymbolMeaningDANGERDANGER!This symbol alerts you to a dangerous situation. Failure to avoid this situation will result inserious or fatal !This symbol alerts you to a dangerous situation. Failure to avoid this situation can result inserious or fatal !This symbol alerts you to a dangerous situation. Failure to avoid this situation can result inminor or medium !This symbol contains Information on procedures and other facts which do not result inpersonal symbolsSymbolMeaningSymbolMeaningDirect currentAlternating currentDirect current and alternating currentGround connectionA grounded terminal which, as far asthe operator is concerned, isgrounded via a grounding ground connectionA terminal which must be connectedto ground prior to establishing anyother connectionA connection that has to be connectedto the plant grounding system.

4 Thismay be a potential equalization lineor a star grounding system dependingon national or company codes for certain types of informationSymbolMeaningPermittedProcedu res, processes or actions that are , processes or actions that are , processes or actions that are additional to documentationReference to pageReference to graphicVisual inspectionMicropilot FMR51, FMR52 Endress+Hauser5 Symbols in graphicsSymbolMeaning1, 2, 3 ..Item numbers,..,Series of stepsA, B, C, ..ViewsA-A, B-B, C-C, ..Sections-Hazardous areaIndicates a hazardous area (non-hazardous area)Indicates the non-hazardous FMR51, FMR526 Endress+HauserFunction and system designMeasuring principleThe Micropilot is a "downward-looking" measuring system, operating based on the time-of-flightmethod (ToF).

5 It measures the distance from the reference point (process connection) to the productsurface. Radar impulses are emitted by an antenna, reflected off the product surface and receivedagain by the radar A0017871 1 Setup parameters of the MicropilotRReference point of the measurement (lower edge of the flange or threaded connection)EEmpty calibration ( = zero)FFull calibration (= span)DMeasured distanceLLevel (L = E - D)InputThe reflected radar impulses are received by the antenna and transmitted into the electronics. Amicroprocessor evaluates the signal and identifies the level echo caused by the reflection of the radarimpulse at the product surface. The unambiguous signal identification is accomplished by thePulseMaster eXact software together with the Multi-echo tracking algorithms, based on manyyears of experience with time-of-flight distance D to the product surface is proportional to the time of flight t of the impulse:D = c t/2,with c being the speed of on the known empty distance E, the level L is calculated:L = E DThe reference point R of the measurement is located at the process connection.

6 For details see thedimensional drawing: FMR51: 64 FMR52 : 70 The Micropilot is equipped with functions to suppress interference echoes. The user can activatethese functions. Together with the multi-echo tracking algorithms they ensure that interferenceechoes ( from edges and weld seams) are not interpreted as level FMR51, FMR52 Endress+Hauser7 OutputThe Micropilot is commissioned by entering an empty distance "E" (=zero), a full distance "F" (=span)and application parameters which automatically adapt the instrument to the process conditions. Formodels with a current output, the factory adjustment for zero point "E" and span "F" is 4 mA and 20mA. For digital outputs and the display module, the factory adjustment for zero point "E" and span "F"is 0 % and 100 %.

7 A linearization with max. 32 points, based on a table entered either manually or semi-automatically,can be activated locally or remotely. This function provides a measurement in engineering units anda linear output signal for spheres, horizontal cylindrical tanks and vessels with conical cycle of the productEngineering Universal measuring principle Measurement unaffected by medium properties Hardware and software developed according to SIL IEC 61508 Procurement Endress+Hauser being the world market leader in level measurement guarantees asset protection Worldwide support and serviceInstallation Special tools are not required Reverse polarity protection Modern, detachable terminals Main electronics protected by a separate connection compartmentCommissioning Fast.

8 Menu-guided commissioning in only a few steps on site or from the control room Plain text display in national languages reduces the risk of error or confusion Direct local access of all parameters Short instruction manual at the deviceOperation Multi-echo tracking: Reliable measurement through self-learning echo-search algorithms takinginto account the short-term and long-term history in order to check the found echoes forplausibility and to suppress interference echoes. Diagnostics in accordance with NAMUR NE107 Maintenance HistoROM: Data backup for instrument settings and measured values Exact instrument and process diagnosis to assist fast decisions with clear details concerningremedies Intuitive, menu-guided operating concept in national languages saves costs for training,maintenance and operation Cover of the electronics compartment can be opened in hazardous areasRetirement Order code translation for subsequent models RoHS-conforming (Restriction of certain Hazardous Substances)

9 , unleaded soldering of electroniccomponents Environmentally sound recycling conceptMicropilot FMR51, FMR528 Endress+HauserInputMeasured variableThe measured variable is the distance between the reference point and the product level is calculated from this distance, taking into account the empty distance "E" entered by required, the level can be converted into other variables (volume, mass) by means of a linearization(up to 32 points).Measuring rangeMaximum measuring rangeDeviceMaximum measuring rangeFMR51 - standard version40 m (131 ft)FMR51 - with "Advanced dynamics" application package70 m (230 ft) FMR52 - standard version40 m (131 ft) FMR52 - with "Advanced dynamics" application package60 m (197 ft)Usable measuring rangeThe usable measuring range depends on the size of the antenna, the reflectivity of the medium, themounting location and eventual interference following tables describe the groups of media as well as the achievable measuring range as afunction of application and media group.

10 If the dielectric constant of a medium is unknown, it isrecommended to assume media group B to ensure a reliable groupsMedia groupsDK ( r) to liquids, liquefied gas 1) to 4non-conducting liquids, benzene, oil, toluene, ..C4 to concentrated acids, organic solvents, esters, aniline, alcohol, acetone, ..D> 10conducting liquids, aqueous solutions, dilute acids and alkalis1) Treat Ammonia NH3 as a medium of group constants (DC values) for many important media are summarized inFor dielectric constants (DC values) of many important media refer to: the DC Manual by Endress+Hauser (CP01076F) by Endress+Hauser the DC Values App by Endress+Hauser (available for Android and iOS) Micropilot FMR51, FMR52 Endress+Hauser9 DeviceStorage tank A0018833 Calm product surface ( intermittent filling, filling from bottom, immersion tubes)Antenna sizeFMR5140 mm (1 in)50 mm (2 in)80 mm (3 in)100 mm (4 in) FMR52 -50 mm (2 in)80 mm (3 in)-A B25(82)15(49)C D3( )10(32)15(49)5(16)8(26)5(16) A0018858 ABCD4(13)8(26)8(26)15(49)12(39)25(82)35( 110)40(131) A0018859 ABCD8(26)15(49)30(98)40(131)10(32)20(65) 40(131)60(197) A0018860 ABCD10(32)25(82)40(131)40(131)15(49)30(9 9)45(148)70(229) A0018862 Measuring range [m (ft)]