Mini-Plus Ceiling System R-410A - Data Aire

ISO 9001 Certifi edMini-PlusCeiling , 3, 4, and 5 tonR-410A3 DATA AIRE S Mini-Plus Ceiling SystemTM is designed for environments where fl oor space is limited. Engi-neered for ducted above Ceiling applications, the Mini-Plus is available in a wide range of System confi gurations and types; air cooled, water/glycol cooled, and chilled water. Split or packaged. Mini-Plus Ceiling Systems function with complete independence from other building air conditioning and ventilation Performance, Low CostThe Mini-Plus Ceiling System is engineered and built by Data Aire, the pioneer in precision cooling equipment. The Mini-Plus offers unparalleled quality at competitive prices.

3 DATA AIRE’S Mini-Plus Ceiling SystemTM is designed for environments where fl oor space is limited. Engi-neered for ducted above ceiling applications, the Mini- Plus is available in a wide range of system con fi gurations and types; air cooled, water/glycol cooled, and chilled

Tags:

  System, Plus, Mini, Ceiling, Ducted, 410a, Mini plus ceiling system r 410a

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Mini-Plus Ceiling System R-410A - Data Aire

1 ISO 9001 Certifi edMini-PlusCeiling , 3, 4, and 5 tonR-410A3 DATA AIRE S Mini-Plus Ceiling SystemTM is designed for environments where fl oor space is limited. Engi-neered for ducted above Ceiling applications, the Mini-Plus is available in a wide range of System confi gurations and types; air cooled, water/glycol cooled, and chilled water. Split or packaged. Mini-Plus Ceiling Systems function with complete independence from other building air conditioning and ventilation Performance, Low CostThe Mini-Plus Ceiling System is engineered and built by Data Aire, the pioneer in precision cooling equipment. The Mini-Plus offers unparalleled quality at competitive prices.

2 Every Mini-Plus System comes with Data Aire s commitment to excellence which began with its fi rst pre-cision cooling machine and has been tested and proven for more than thirty years. Data Aire DeliversMini- plus Ceiling Systems are not standard units shipped from stock. Each unit is built to specifi c needs and re-quirements. The standard ship cycle is ten working days from date of order. Optional premium orders can be expedited in one week. Call your local Data Aire sales representative for details. Design Features .. 4 - 8 Options .. 9 - 10 Standard Unit Model Number Identifi Shipping Weights ..13 Performance Data Air Cooled .. 14 - 17 Water Cooled.

3 18 - 21 Chilled Water .. 22 - 25 Electrical Data Index ..26 Unit Drawings ..57 Guide Specifi cations ..90 Table of Contents4 CONTROL SYSTEMS tandard units are shipped with Data Aire s wall mounted microprocessor mini Data Alarm electrical components including capacitors, relays, and control transformers are pre-wired. Each unit is provided with a mi-croswitch to prevent condensate pan overfl ow. The microswitch will disable the unit prior to pan overfl ow should the drain line become plugged with debris. ELECTRIC REHEAT6 kW reheat is standard on through 4 ton Mini-Plus units (5 ton Mini-Plus units have 6 kW reheat on single phase and 12 kW reheat on three phase). Electric reheat is accomplished with low watt, low density fi nned tube fabricated of stainless steel core sheath with plated fi ns to withstand moist conditions.

4 Reheat is installed on the air discharge side of the cooling coil and provides ample capacity to maintain room dry bulb conditions during dehumidifi cation. Low-watt density coils eliminate ionization associ-ated with open air electric resistance indoor sections are constructed with tubular steel frames for strength and service access. Removable galvanized steel panels are lined with 1/2 inch thick closed cell insulation for quiet and effi cient operation. An integral fi lter section with 2 fi lters is COOLED - PACKAGED SYSTEME vaporator SectionThe evaporator section is a draw-through type with double width, double inlet blower with belt drive and variable pitch sheave. The self-aligning ball bearings are rated for a mini -mum life of 100,000 evaporator coil is constructed of copper tubes and alumi-num fi ns.

5 The single stage refrigeration circuit includes an expansion valve with external equalization. A stainless steel drain pan is standard. Condensing SectionThe attached condensing unit contains a scroll compressor with crankcase heater, fi lter drier, sight glass, and condenser coil. The condenser coil is constructed with copper tubes and aluminum fi ns. The condenser blower is double inlet, double width with belt drive and variable pitch sheave. Field supplied return and supply air ductwork is required for all Mini-Plus evaporator and condensing sections.(See drawing - 535-900-001)AIR COOLED - SPLIT System withINDOOR CONDENSING UNITE vaporator SectionThe evaporator section is a draw-through type with double width, double inlet blower with belt drive and variable pitch sheave.

6 The self-aligning ball bearings are rated for a mini -mum life of 100,000 evaporator coil is constructed of copper tubes and alumi-num fi ns. The expansion valve with external equalization is contained in the evaporator section. A stainless steel drain pan is standard. Condensing SectionThe condensing unit contains a scroll compressor with crank-case heater, fi lter drier, sight glass, and condenser coil. The condenser coil is constructed with copper tubes and aluminum fi ns. The condenser blower is double inlet, double width with belt drive and variable pitch sheave. Field supplied return and supply air ductwork is required for all Mini-Plus evaporator and condensing sections. Field piping and wiring is required between the indoor evapo-rator and condensing unit sections.

7 (See drawing 535-900-002)DESIGN FEATURESDESIGN FEATURES5 AIR COOLED - SPLIT System with INDOOR CONDENSERE vaporator/Compressor SectionThe evaporator section is a draw through type with double width, double inlet blower with belt drive and variable pitch sheave. The self-aligning ball bearings are rated for a mini -mum life of 100,000 hours. The evaporator coil is constructed of copper tubes and aluminum fi ns. The expansion valve with external equalization is contained in the evaporator section. A stainless steel drain pan is standard. The condensing section is contained in a side car and at-tached to the evaporator section. The condensing section includes a scroll compressor with crankcase heater, fi lter drier and sight glass.

8 Condenser SectionThe condenser section includes a condenser coil and condenser blower. The condenser coil is constructed of copper tubes and aluminum fi ns. The blower is double inlet, double width with belt drive and variable pitch sheave. Field supplied return and supply air ductwork is required for all Mini-Plus evaporator and condenser piping and wiring is required between the indoor evapo-rator/compressor and the condenser power source is provided at the evaporator section, for both sections, unless ordered with optional separate power sources.(See drawing - 535-900-008)AIR COOLED - SPLIT System with OUTDOOR CONDENSING UNITE vaporator SectionThe evaporator section is a draw-through type with double width, double inlet blower with belt drive and variable pitch sheave.

9 The self-aligning ball bearings are rated for a mini -mum life of 100,000 evaporator coil is constructed of copper tubes and alumi-num fi ns. The single stage refrigeration circuit includes an expansion valve with external equalization. A stainless steel drain pan is standard. Field supplied return and supply air ductwork is required for all Mini-Plus evaporator COOLED - SPLIT System with OUTDOOR CONDENSING UNIT, continuedOutdoor Condensing SectionThe condensing unit contains a scroll compressor with crank-case heater, fi lter drier, sight glass, and condenser coil. The condenser coil is constructed with copper tubes and aluminum fi ns. The galvanized steel housing and fan guard are powder coated for longer life.

10 The energy effi cient condenser fan is thermally protected. Air discharge is vertical. The condenser fan is variable speed for head pressure control to -20 F ambi-ent piping and wiring is required between the indoor evapo-rator section and the outdoor condensing unit.(See drawing - 535-900-005)AIR COOLED - SPLIT System with OUTDOOR CONDENSERE vaporator/Compressor SectionThe evaporator section is a draw through type with double width, double inlet blower with belt drive and variable pitch sheave. The self-aligning ball bearings are rated for a mini -mum life of 100,000 hours. The evaporator coil is constructed of copper tubes and aluminum fi ns. The expansion valve with external equalization is contained in the evaporator section.