Example: barber

Model 3144 and 3244MV Smart Temperature …

00809-0100-4724 EnglishRev. CAModel 3144 and 3244 MVSmart TemperatureTransmittersProductManualMode l 3144 and 3244MV SmartTemperature TransmittersModel 3144 and 3244MV Communicator Field Device Revision:Dev. v2, DD v1 Rosemount Models 3144 and 3244MV Smart Temperature Transmitters may be protected by one or Patents Pending. Other foreign patents , the Rosemount logotype, Smart FAMILY, Hot Backup, and Tri-Loop are registeredtrademarks of Rosemount is a registered trademark of du Pont de Nemours & is a registered trademark of the HART Communication is a trademark of Pomona is a registered trademark of International Nickel PHOTO: 3144-010 ACNOTICERead this manual before working with the product.

Product Manual Model 3144 and 3244MV Smart Temperature Transmitters Model 3144 and 3244MV Revision: 5.2.1 HART Communicator Field Device Revision: Dev. v2, …

Tags:

  Smart, Temperatures, Transmitter, And 3244mv smart temperature, 3244mv, And 3244mv smart temperature transmitters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Model 3144 and 3244MV Smart Temperature …

1 00809-0100-4724 EnglishRev. CAModel 3144 and 3244 MVSmart TemperatureTransmittersProductManualMode l 3144 and 3244MV SmartTemperature TransmittersModel 3144 and 3244MV Communicator Field Device Revision:Dev. v2, DD v1 Rosemount Models 3144 and 3244MV Smart Temperature Transmitters may be protected by one or Patents Pending. Other foreign patents , the Rosemount logotype, Smart FAMILY, Hot Backup, and Tri-Loop are registeredtrademarks of Rosemount is a registered trademark of du Pont de Nemours & is a registered trademark of the HART Communication is a trademark of Pomona is a registered trademark of International Nickel PHOTO: 3144-010 ACNOTICERead this manual before working with the product.

2 For personal and system safety, andfor optimum product performance, make sure you thoroughly understand the contentsbefore installing, using, or maintaining this the United States, Rosemount Inc. has two toll-free assistance numbers:Customer CentralTechnical support, quoting, and order-related (7:00 am to 7:00 pm CST)North American Response CenterEquipment service (24 hours includes Canada)Outside of the United States, contact your local Rosemount products described in this document are NOT designed for nuclear-qualifiedapplications.

3 Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate information on Rosemount nuclear-qualified products, contact your local RosemountSales satisfies all obligations coming from legislationto harmonise product requirements in the European Market BoulevardChanhassen, MN 55317 USATel 1-800-999-9307 Telex 4310012 Fax (612) 949-700100809-0100-4724 Rosemount Inc. 1999 of ContentsSECTION Acquainted with the ..2-1 Commissioning: On the Bench or in the.

4 2-3 Power ..2-7 Changing the Position of the Failure Mode or Ohm or Millivolt ..2-12 Hazardous Locations in Conjunction with a Model 333 HART Tri-Loop HART-to-Analog Signal the transmitter for Use with theHARTTri-Loop ..2-17 Rosemount Model 3144 and 3244MV Smart Temperature TransmittersviSECTION 3On-line ..3-1 Setting the Loop to .. and ..3-15 DecidingWhichTrimProceduretoUse .. of ContentsSECTION 5 Specifications andReference ..5-7 TransmitterDimensionalDrawings .. Sensor Sensor Detect (Advanced Function).

5 5-18 SECTION ..6-1 Custom transmitter Configuration (Option Code C1) .. 6-1 Trim to Specific Rosemount RTD Calibration Schedule( transmitter -Sensor Matching) (Option Code C2)..6-1 Five-PointCalibration(OptionCodeC4) ..6-1 CalibrationCertificate(OptionCodeQ4)..6- 2 TrimtoSpecialSensor(OptionCodeC7)..6-2 MountingBrackets(OptionCodesB4andB5)..6- 2 AssemblyOptions(OptionCodeX1,X2,andX3).. 6-3 External Ground Lug Assembly (Option Code G1)..6-350 HzLineVoltageFilter(OptionCodeF5)..6-3 NAMUR Compliant Operation(OptionCodesA1andCN).

6 6-3 TransientProtection(OptionCodeT1)..6-4 HotBackup(OptionCodeU1) ..6-4 Average Temperature with Hot Backup and Drift Alert(OptionCodeU2)..6-5 TwoIndependentSensors(OptionCodeU4) ..6-5 DifferentialTemperature(OptionCodeU5)..6 -5 AverageTemperature(OptionCodeU6)..6-5 LCDM eter(OptionCodeM5)..6-6 Installing the Model 3144 and 3244MV Smart Temperature TransmittersviiiAPPENDIX ATransmitter ..A-1 APPENDIX BModel 275 HART ..B-2 Model 3144 and 3244MV Menu and ..B-9 Diagnostic CModel 268 Smart FAMILY ..C-13144 and.

7 C-3 AlphanumericandShiftKeys ..C-4 FunctionKeys ..C-5 FunctionKeySequences ..C-5 Diagnostics DHazardous Area ApprovalInstallation .. THIS MANUALThis manual is intended to assist in installing, operating, and maintaining Rosemount Model 3144 and 3244MV Smart Temperature Transmitters. Section 2: InstallationSection 2 explains how to commission transmitters; provides an installation flowchart; and describes electrical, mechanical, and environmental installation 3: On-line OperationsSection 3 describes how to configure transmitter software, select a sensor type, adjust the input and output electronics; and how to change output characteristics (range settings, output type, damping, and units) and non-output-related transmitter characteristics (including the transmitter tag number, date, and message).

8 Section 4: MaintenanceSection 4 describes hardware diagnostics, maintenance tasks, and hardware 5: Specifications and Reference DataSection 5 lists functional, performance, and physical specification data for the transmitter . This section also includes transmitter drawings, ordering information, and a list of spare 6: OptionsSection 6 presents options including the LCD meter, mounting brackets, custom configuration and calibration, trim to special sensor, and external ground-lug A: transmitter ImprovementsAppendix A describes the enhancements that have been made to the Model 3144 and 3244MV Smart Temperature Transmitters, and includes a chart that compares previous transmitter versions to the current improved transmitter B.

9 Model 275 HART CommunicatorAppendix B provides a complete menu tree, a table of fast key sequences, and other information regarding use of the Model 275 HART C: Model 268 Smart FAMILY InterfaceAppendix C provides a complete menu tree and other information regarding use of the Model 268 Smart FAMILY D: Hazardous Area Approval Installation DrawingsAppendix D provides hazardous location installation Model 3144 and 3244MV Smart Temperature Transmitters1-2 GETTING ACQUAINTEDWITH THE TRANSMITTERThe Rosemount Model 3144 and 3244MV Smart Temperature Transmitters are microprocessor-based instruments that accept input from a wide variety of sensors, and transmit Temperature data to a control system or transmitter interface.

10 The transmitters combine Rosemount reliability with the flexibility of digital electronics. The transmitters are ideal for applications that require high performance or remote transmitter is designed to communicate with a HART communicator. Communicators are used to interrogate, configure, test, or format the transmitter , as well as other products in the Rosemount family of microprocessor-based instruments. Moreover, HART communicators can communicate with a transmitter from the control room, from the transmitter site, or from any other wiring termination point in the loop where there is between 250 and 1100 ohms resistance between the transmitter power connection and the power dual-sensor features of the Model 3244MV include Hot Backup , drift alert, differential and average Temperature measurements.


Related search queries