Example: dental hygienist

Modular Lube Lubrication Systems System Controls

26 Modular Lube Lubrication SystemsSystem ControlsModelRegisterOil Inlet/OutletMax. Pressure Ratingpsig / bar87806200 counts per pint " NPTF(F)6000 / 408 Flow MeterFlow meter measures and records oil flow to the (s)Electrical PowerDisplayAlarm Time3rd PartyMonitoredRequirementsRecordApproval spintsMin. VAC, 50-60 Hz999, 10 CSA Class I, Group D87611224 II, Group E, F & GCycle MonitorsCycle Monitors monitor and record oil flow volume delivered to lube points and signal fault if flow stops or diminishes 84501 Program Timer Solid StateDesigned to control the Lubrication cycle frequency of air-operated single-strokepumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid valve (not included) installed in the air line to pump. Off TimeOn TimePowerApprovalsSwitch(Cycle Time)(Pumping Time)RequirementsCapacityMinMaxMinMax20 VACUL, CSA120 VAC, 5 Amps24 Hz230 VAC, AmpsModel 84511 Economy Timer for Single Stroke PumpsUses a timing motor, cam and Micro-Switch to turn pump off and on.

Modular Lube® Lubrication Systems System Controls 28 Model 85500 System Sentry II The ultimate automated lubrication system controller/monitor now features greater monitoring accuracy with less sensitivity to lubricant flow rates, feed line length or

Tags:

  System, Control, Automated, Lubrication, Automated lubrication, Lubrication systems system controls

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Modular Lube Lubrication Systems System Controls

1 26 Modular Lube Lubrication SystemsSystem ControlsModelRegisterOil Inlet/OutletMax. Pressure Ratingpsig / bar87806200 counts per pint " NPTF(F)6000 / 408 Flow MeterFlow meter measures and records oil flow to the (s)Electrical PowerDisplayAlarm Time3rd PartyMonitoredRequirementsRecordApproval spintsMin. VAC, 50-60 Hz999, 10 CSA Class I, Group D87611224 II, Group E, F & GCycle MonitorsCycle Monitors monitor and record oil flow volume delivered to lube points and signal fault if flow stops or diminishes 84501 Program Timer Solid StateDesigned to control the Lubrication cycle frequency of air-operated single-strokepumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid valve (not included) installed in the air line to pump. Off TimeOn TimePowerApprovalsSwitch(Cycle Time)(Pumping Time)RequirementsCapacityMinMaxMinMax20 VACUL, CSA120 VAC, 5 Amps24 Hz230 VAC, AmpsModel 84511 Economy Timer for Single Stroke PumpsUses a timing motor, cam and Micro-Switch to turn pump off and on.

2 NEMA 1enclosure, UL and CSA listed. Switch capacity 10 amps non-inductive. Off TimeOn TimePowerApprovalsSwitch(Cycle Time)(Pumping Time)RequirementsCapacityMinMaxMinMax5 VAC, 60 HzUL, CSA10 AmpsBuilt-In Program OptionsEnclosureAmbient Operating Temperature Range3 Hr. Program MaximumMemoryFunctionHeight Width DepthYesNoYesNoNEMA #18 6 4 0 F 130 F210173125-18 C54 CEnclosureRatingDimensions - in. / mmHeightWidthDepthNEMA 15 / 1273 / / 89 Note: Off-time selectable in 5 minute :Refer to Technical Manual for a full explanation of available program Lube Lubrication SystemsSystem ControlsModel 85530 Lubrication System ControllerControls Lubrication frequency, master divider valve cycle and monitors supply linepressure. The LCD displays operating 84015 Timer 12-24V DCSolid-state microprocessor-based controller for automated Lubrication Systems onmobile equipment or where AC power is not available.

3 Rugged construction withliquid- and dust-tight enclosure. Includes manual push-button for remote initiation of a lube cycle. Off Time**Fixed On TimePowerSwitch(Cycle Time)(Pumping Time) VDC5 Amps25 MA*EnclosureAmbient Operating Temperature Range RatingDimensions-in. / mmMinimumMaximumHeightWidthDepthNEMA 125 / 1333 / 793 / 760 F / -18 C131 F / 55 C* Less load.** Available selections are , 5, 10, 20, 40 or 80 TimeTimer ModeCounter ModeCountBefore AlarmOff TimeOff * ,900199,00030 99 Minute Minutes CountCounts@ 50%MinuteMinutes Duty CycleNotes: Model 85530 is CSA/NRTL approved.* Minimum duration of count signal is 33 Requirements (less load)Pump,AmbientEnclosureSolenoid, Temperature RatingDimensions-in. / mmVoltageCurrentor AlarmRangeCapacityHeight Width Depth120 VAC, 50/60 Hz85 MA360 VA32 to 122 FNEMA9 8 4 230 VAC, 50/60 HZ45 MA-0 to +50 C1224122710524 VDC250 MA5 AmpsModular Lube Lubrication SystemsSystem Controls28 Model 85500 System Sentry IIThe ultimate automated Lubrication System controller/monitor now features greater monitoring accuracy with less sensitivity to lubricant flow rates, feed line length or bearing back-pressure.

4 System Sentry II is always on the job, making sure that every lube point is lubricated when it s supposed to be. Solid-state controller with LCD status display and 16-button keypad for System programming Controls up to two pumps with as many as two lube zones per pump Fully programmable monitoring and alarm functions Be set up to monitor every lube point for lubricant flow during each Lubrication event Easy to understand prompts reported by simple English language messages in real timeSome functions require optional accessories. See chart on page a maximum or 48 sensors and three accessory Sensor Boards (order separately 16 sensors per board) to monitor lube points. For more than 48 sensors, use Model 85510 Satellite plus additional Sensor Boards for a maximum of 1536 lube 243100 Sensor Wire100 foot ( meters) coil of two conductor 22-gauge wire for connecting sensors tomonitor.

5 Maximum length of wire between sensor and monitor is 500 feet (152 meters).Lube TimeTimer ModeCounter ModeCountBefore AlarmOff TimeOff * ,900199,00030 @ 50% kgDuty CycleNote: Model 85500 is CSA/NRTL approved.* No external load, no sensors.* Minimum duration of count signal is 33 Requirements (less load)Pump,AmbientEnclosureSolenoid, Temperature Dimensions-in. / mmVoltageCurrentor AlarmRangeRatingCapacityHeight Width Depth120 VAC, 50/60 Hz250 MA*360 VA32 to 122 FNEMA16144 230 VAC, 50/60 HZ125 MA*0 to 50 C1224122710524 VDC600 MA*5 AmpsModular Lube Lubrication SystemsSystem Controls29 Model 247333 Pressure TransducerPressure Transducer signals actual System pressure via LCD display of SystemSentry II. Comes with 72 inch ( ) shielded 24-gauge connecting wire. Maximumlength of wire between transducer and monitor is 30 ( ) 250365 Sensor BoardPlug-in accessory board used with Model 85500 that allows the attachment of upto 16 lube flow sensors.

6 Model 85500 comes without boards installed and can holdup to a total of three. Sensor AssembliesSensor assemblies consist of a check body and lube sensor with attached 30'cable. Cables are epoxy potted into the sensors for a watertight seal. Sensors havea " pipe thread for conduit connection and a Viton O-ring seal. Check bodies terminate in a " NPTF male thread for attachment to a bearing or other lubricantinlet. Maximum working pressure 6,000 psi (414 bar). Maximum wire run from sensor to monitor is 500 feet (152m).Range 4X0 to 1 %7500 psig " NPT-20 to 180 F10 to1-6 1 Rating4000 psi517 barMale Thread -29 to 82 C30 VDCVDC 300 Series276 barVDCS tainlessSteelLubricantMin. FlowMin. IntervalModelDescriptionConstructionTemp . RangePer EventBetween LubeFlow Event250400 Straight Sensor AssemblyBrass Sensor25049090 Sensor & Plated Steel32 to 145 FAssemblyCheck Body0 to 63 C30 Seconds250500 Straight SensorSensor & AssemblyCheck Body25059090 Sensor316 AssemblyStainless cu.

7 Cc@ 32 F /0 C to125 F/52 cu. cc@ 126 F to 145 F(53 C to 63 C) Modular Lube Lubrication SystemsSystem Controls30 Pressure SensorSensor WireFunctionSwitchBoardSensors#243100 (100')#69630#250365 Note 2 Note 3 Lube Controller1 Pump, 1 ZoneOptional 1 Note 1 Lube Controller,1 Pump,Optional 1 Up to 3 ZonesLube Controller,2 Pumps, 1 Zone Optional 1 Per PumpLube Controller,2 Pumps, Up to 2 Optional 1 Zones Per PumpLube PointRequiredRequiredRequiredMonitoring 1 per each1 perQuantity 48 Points16 SensorsLube PointAs NeededLube PointRequiredRequiredRequiredMonitoring 1 per each1 perQuantity> 48 1536 Points16 SensorsLube PointAs NeededNote 1: Controller may be operated without a pressure switch. Pressure switch may be used to monitor supply line 2:Sensors include 30' ( ) cable pigtail. Select brass/plated steel or stainless steel sensors instraight or 90 configuration as 3:Maximum distance between monitor and sensor is 500' (152 meters).

8 Use This Guide to Select Accessories for Model 85500 System Sentry II31 Modular Lube Lubrication SystemsSystem ControlsModel 83354 Signal MonitorDesigned to provide visual and audible indication of System operation and signal from System controller. Includes model 69606 Alarm Horn mountedon enclosure door. PowerIndicator LampsAudibleDimensions - in / mmRequirementPower Lube System AlarmOnSystem On FailureHeight Width Depth115 VAC69606 Horn108650/60 HzGreenAmberRed(included)25420315235 VAElectric Solenoid-Operated Air ValvesEElleeccttrriiccaall CChhaarraacctteerriissttiiccssPPoowweerr IInnrruusshhHHoollddiinnggAAiirr // bbaarr110 VAC, 50 Hz350244120 VAC, 60 VA0 to 120 VAC, 50 Hz-18 to 49 C350245240 VAC, 60 VA1 4"1 2" NPS(F)110 VAC, 50 HzNPT(F)350241120 VAC, 60 VA150220 VAC, 50 VAC, 60 VA35028212 VDC0 to 140 F6 WattsN/AN/A1 8"-18 to 60 CN/A35028324 VDCNPT(F)6 Watts68586 2-Way120V, 60 8" 2" NPT(F)12 VANPT(F)274398 3-Way24 VDCN/AN/A1 4".

9 5 WattsNPT(F)110 VAC, 50 Hz3 8"0 to 120 F244727 3-Way 120 VAC, 60 (F)-18 to 49 2" NPT(F)11 VA


Related search queries