Example: confidence

Modular Type Regulators Series AR - SMC Pneumatics

345 Modular TypeRegulatorsSeries ARRegulatorSeries ARRegulator with Backflow FunctionSeries AR KModelAR10AR20AR25AR30AR40AR40-06AR50AR6 0AR20 KAR25 KAR30 KAR40 KAR40K-06AR50 KAR60 KPort sizeM5 x , 1/41/4, 3/81/4, 3/81/4, 3/8, 1/23/43/4, 111/8, 1/41/4, 3/81/4, 3/81/4, 3/8, 1/23/43/4, 11 Pages 346 through to 355 Pages 346 through to 355 OptionsBracketSquare embedded type pressure gauge (except the AR10)Round type pressure gaugeDigital pressure switch(except the AR10)Panel mountACAF ARALAW A 2:06 PM Page 345 How to OrderAR30q03rBEtyKweJIS SymbolRegulatorRegulator with Backflow FunctionMade to Order(Refer to pages 354 and 355 for details.) With the backflow function it incorporates a mechanism to exhaust the air pressure in the outlet side reliably and quickly. Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be en-sured for a safety 1) When the pressure in the rear and the front of the cylinder differs: Option/Semi-standard: Select one each for a to g.

345 Modular Type Regulators Series AR Regulator Series AR Regulator with Backflow Function Series AR K Model AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60 AR20K AR25K AR30K

Tags:

  Series, Types, Modular, Regulators, Modular type regulators series ar

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Modular Type Regulators Series AR - SMC Pneumatics

1 345 Modular TypeRegulatorsSeries ARRegulatorSeries ARRegulator with Backflow FunctionSeries AR KModelAR10AR20AR25AR30AR40AR40-06AR50AR6 0AR20 KAR25 KAR30 KAR40 KAR40K-06AR50 KAR60 KPort sizeM5 x , 1/41/4, 3/81/4, 3/81/4, 3/8, 1/23/43/4, 111/8, 1/41/4, 3/81/4, 3/81/4, 3/8, 1/23/43/4, 11 Pages 346 through to 355 Pages 346 through to 355 OptionsBracketSquare embedded type pressure gauge (except the AR10)Round type pressure gaugeDigital pressure switch(except the AR10)Panel mountACAF ARALAW A 2:06 PM Page 345 How to OrderAR30q03rBEtyKweJIS SymbolRegulatorRegulator with Backflow FunctionMade to Order(Refer to pages 354 and 355 for details.) With the backflow function it incorporates a mechanism to exhaust the air pressure in the outlet side reliably and quickly. Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be en-sured for a safety 1) When the pressure in the rear and the front of the cylinder differs: Option/Semi-standard: Select one each for a to g.

2 Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AR30K-03BE-1NR++++10202530405060 Body sizeDescriptionWithout backflow functionWith backflow functionSymbolNilK Note 1)NilB Note 3)HWith backflowfunctionMountingMetric thread (M5)RcNPTGNilNFThread typeM51/81/43/81/23/41M5010203040610 Port sizeaWithout mounting optionWith bracketWith set nut (for panel fitting)NilEGME1 Note 4)E2 Note 4)E3 Note 4)E4 Note 4)PressuregaugeDigitalpressureswitchbWit hout pressure gaugeSquare embedded type pressure gauge (with limit indicator)Round type pressure gauge (without limit indicator)Round type pressure gauge (with limit indicator)Round type pressure gauge (with color zone)Output: NPN output / Electrical entry: Wiring bottom entry Output: NPN output / Electrical entry: Wiring top entryOutput: PNP output / Electrical entry: Wiring bottom entry Output: PNP output / Electrical entry: Wiring top entryNote 2)Option346 RegulatorAR10 to AR60 Regulator with Backflow FunctionAR20K to 2.

3 06 PM Page 346AR40, AR40 KAR20, AR20 KNote 1) Pressure gauge connection threads are not available for unit with a square embedded type pressure gauge (AR20(K) to AR60(K)).Note 2) Use a bushing (part no:131368) when connecting the R1/8 pressure gauge to the Rc1 3) 5 to 50 C for the products with the digital pressure 4) Not applicable to the to MPaModelPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 3)Proof pressureMaximum operating pressureSet pressure rangeRelief pressure Note 4)ConstructionMass (kg)AR20(K)AR10M5 x Note 2) to , 1 (K)1/4, 3/81 (K)1/4, 3 (K)1/4, 3/8, 1 (K)-063 (K)3/4, (K) 1) The AR10 type comes with a backflow function as a standard feature. (K is not available.) When using the AR10 type as w/ backflow function, backflow may not occur with the set pressure MPa or less. Please set the inlet pressure to at least MPa higher than the set 2) Option B, G, H, M are not assembled and supplied loose at the time of 3) Assembly of a bracket and set nuts (AR10, AR20(K) to AR40(K))Including 2 mounting screws for the AR50(K) and AR60(K)Note 4) When choosing with H (panel mount), the installation space for lead wires will not be secured.

4 In this case, select wiring top entry for the electrical entry. (Select wiring bottom entry when the semi-standard Y is chosen simultane-ously.)Note 5) Only the AR10 has a pressure setting of to 6) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of MPa or more. When the pressure gauge is attached, a MPa pressure gauge will be fitted. Note 7) For thread type: M5 and NPT. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi 8) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in Japan.)Note 9) : For thread type: M5 and NPT onlyNote 10) : Select with options: E1, E2, E3, 5 to 60 C (with no freezing) MPaSet pressure + MPa [at relief flow rate of l/min (ANR)]Relieving type++++DescriptionSymbolNil Note 5)1 Note 6)Set to MPa to MPa settingNilNExhaustmechanismdRelieving typeNon-relieving type102025304050 NilRFlow directioneFlow direction: Left to rightFlow direction: Right to leftNilYKnobfDownwardUpwardNilZ Note 7)ZA Note 8)Pressure unitgName plate and pressure gauge in imperial units: MPaName plate and pressure gauge in imperial units: psiDigital pressure switch: With unit conversion functionNote 9)Note 10)Note 9)Note 10)Note 9)Note 10)Note 9)Note 10)Note 9)Note 10)Note 9)Note 10)Note 9)60 Body sizeSemi-standard347 Regulator Series AR10 to AR60 Regulator with Backflow Function Series AR20K to AR60 KACAF ARALAW A 2.

5 06 PM Page 347348 Series AR10 to AR60 Series AR20K to AR60 KSpecific Product PrecautionsSelection1. Residual pressure disposal (outlet pressure removal) is not possible for the AR20 to AR60 even though the inlet pressure is exhausted. When the residual pressure disposal is per-formed, use the regulator with a backflow function (AR20K to AR60K). WarningMaintenance1. When using the regulator with backflow function between a solenoid valve and an actuator, check the pressure gauge peri-odically. Sudden pressure fluctuations may shorten the durabil-ity of the pressure gauge. A digital pressure gauge is recom-mended for such situation or as deemed and Adjustment1. Set the regulator while verifying the displayed values of the in-let and outlet pressure gauges. Turning the regulator knob ex-cessively can cause damage to the internal The pressure gauge included with Regulators for to MPa setting is for up to MPa use only (except the AR10).

6 Exceeding MPa of pressure can damage the Do not use tools on the pressure regulator knob as this may cause damage. It must be operated Be sure to unlock the knob before adjusting the pressure and lock it after setting the pressure. Failure to follow this proce-dure can cause damage to the knob and the outlet pressure may fluctuate. Pull the pressure regulator knob to unlock. (You can visually verify this with the orange mark that appears in the gap.) Push the pressure regulator knob to lock. When the knob is not easily locked, turn it left and right a little and then push it (when the knob is locked, the orange mark , , the gap will disappear).2. A knob cover is available to prevent careless operation of the knob. Refer to page 389 for markBe sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions and pages 287 to 291 for Precautions.

7 Note 1) Assembly of a bracket and set nutsNote 2) Assembly of a bracket and 2 mounting screwsNote 3) Please consult with SMC regarding the set nuts for the AR50(K) and AR60(K).Note 4) in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for NPT. Please contact SMC regarding the connection thread NPT and pressure gauge supply for psi unit 5) Pressure gauge for general purposeNote 6) Including one O-ring and 2 mounting screws. [ ]: Pressure gauge cover onlyNote 7) Lead wire with connector (2 m), adapter, lock pin, O-ring (1 pc.), mounting screw (2 pcs.) are attached. [ ]: Switch body onlyAlso, regarding how to order the digital pressure switch, please refer to page 5) AR25P-270 ASAR25P-260SG36-10- 01G36-2- 01G36-10- 01-LG36-2- 01-LAR30P-270 ASAR30P-260 SAR40P-270AS AR40P-260S AR50P-270AS Note 2) Note 3) Note 3) to MPa to MPa to MPa settingNPN output: Wiring bottom entryNPN output: Wiring top entryPNP output: Wiring bottom entryPNP output.

8 Wiring top entryModelOptionBracket assembly Note 1)Set nutPress-uregaugeNote 4)Note 4)Note 6)Digital pressureswitchAR10AR25(K)AR20(K)AR30(K)A R40(K)AR40(K)-06AR50(K)AR60(K)Round type Squareembedded typeRound type (with color zone) G46-10- 02G46-2- 02G46-10- 02-LG46-2- 02-LGC3-10AS [GC3P-010AS (Pressure gauge cover only)]GC3-2AS [GC3P-010AS (Pressure gauge cover only)]ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] Note 7)ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] Note 7)ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] Note 7)ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] Note 7) 2:06 PM Page (K)Rc 3/8 Flow rate (l/min (ANR))Outlet pressure (MPa) rate (l/min (ANR))Outlet pressure (MPa)AR40(K)Rc 1 (K)Rc 3/8 Flow rate (l/min (ANR))Outlet pressure (MPa)50010001500AR50(K)Rc rate (l/min (ANR))Outlet pressure (MPa) (K)-06Rc 3/4 Flow rate (l/min (ANR))Outlet pressure (MPa) (K)Rc 1/4 Flow rate (l/min (ANR))Outlet pressure (MPa) rate (l/min (ANR))Outlet pressure (MPa)AR60(K)Rc rate (l/min (ANR))Outlet pressure (MPa)349 Flow Characteristics (Representative values)Condition: Inlet pressure MPaRegulator Series AR10 to AR60 Regulator with Backflow Function Series AR20K to AR60 KACAF ARALAW A 2.

9 06 PM Page 34900 pressure (MPa) pressure (MPa) (K)Inlet pressure (MPa)Outlet pressure (MPa) (K)Inlet pressure (MPa)Outlet pressure (MPa) (K)-06 Inlet pressure (MPa)Outlet pressure (MPa) (K)Inlet pressure (MPa)Outlet pressure (MPa) (K)Inlet pressure (MPa)Outlet pressure (MPa) (K)Inlet pressure (MPa)Outlet pressure (MPa) (K)Inlet pressure (MPa)Outlet pressure (MPa)Set pointSet pointSet pointSet pointSet pointSet pointSet pointSet point350 Pressure Characteristics (Representative values)Conditions: Inlet pressure MPa, Outlet pressure MPa, Flow rate 20 l/min (ANR) Series AR10 to AR60 Series AR20K to 2:06 PM Page 350AR20K to AR60K (Regulator with Backflow Function)qterwINOUT tqerwINOUT qterwINOUT terqwINOUTA-AyACSM2 OUT1I NAComponent die-castAluminum die-castPolyacetalAluminum die-castModelAR10, AR20(K)AR25(K) to AR60(K)AR10, AR20(K) to AR40(K)-06AR50(K), AR60(K)Platinum assemblyDiaphragm assemblyValve guide assemblyCheck valve assembly Note 2)MaterialBrass, HNBRP olyacetal WeatherableNBRPart (K)AR25(K)AR30(K)AR40(K)AR50(K)AR40(K)-0 6AR60(K)AR10P-090 SAR10P-150AS Note 1)131329 AR20P-410 SAR20P-150 ASAR20P-050 ASAR25P-410 SAR25P-150 ASAR25P-050 ASAR30P-410 SAR30P-150 ASAR30P-050 ASAR40P-410 SAR40P-150 ASAR40P-050 ASAR50P-410 SAR50P-150 ASAR50P-050 ASAR20KP-020 ASAR60P-050 ASAR60P-410S3456 Replacement PartsNote 1) The AR10 is a piston type.

10 Assembly of a piston and a seal (KSYP-13).Note 2) Check valve assembly is applicable for a regulator with backflow function (AR20K to AR60K) only. Assembly of a check valve cover, check valve body assembly and 2 screws351 ConstructionAR10AR20(K), AR25(K)AR30(K), AR40(K)AR50(K), AR60(K)Regulator Series AR10 to AR60 Regulator with Backflow Function Series AR20K to AR60 KACAF ARALAW A 2:06 PM Page 351wqqwCSM2 OUT1I NAArqeINOUT wwrqeA-Aw352 Working Principle (Regulator with Backflow Function)AR10AR20K to AR60 KWhen the inlet pressure is higher than the regulating pressure, the check valve operates as a normal regulator (Figure 1).When the inlet pressure is shut off and exhausted, any inlet pressure applied to the valve q will be lost. The force for seating the valve q is the valve spring force w only. When the valve q is opened using the outlet force, the outlet pressure will be exhausted at the inlet side. (Figure 2)When the set pressure is MPa or less, valve q may not open due to the valve spring w 2 Figure 1IN(Inlet pressure)OUT(Outlet pressure)IN(Inlet pressure)OUT(Outlet pressure)When the inlet pressure is higher than the regulating pressure, the check valve w closes and operates as a normal regulator (Figure 1).