ModularVariable SpeedAir Handlers4 TEE3F31B1000B4 TEE3F37B1000B4 TEE3F39A1000A4 TEE3F40B1000B4 TEE3F48B1000A4 TEE3F49C1000A4 TEE3F64A1000A4 TEE3F65B1000B4 TEE3F66A1000 APUB. NO. 22-1717-102 Pub. No. 22-1717-10 Optional EquipmentOPTIONAL EQUIPMENT FOR AIR Handlers (Check mark [ ] indicates accessories included).Plenum Pedestal (4 TEE3F37, 39, 40, 48, 49, 64, 65, 66).. TAYPLNM100 [ ]Sub-base For Downflow (4 TEE3F31).. TAYBASE101 [ ]Sub-base For Downflow (4 TEE3F37, 39, 48, 64).. TAYBASE100 [ ]Sub-base For Downflow (4 TEE3F40, 49, 65, 66).

Modular Variable Speed Air Handlers 4TEE3F31B1000B 4TEE3F37B1000B 4TEE3F39A1000A 4TEE3F40B1000B 4TEE3F48B1000A 4TEE3F49C1000A 4TEE3F64A1000A 4TEE3F65B1000B

Tags:

  Speed, Modular, Handlers, Variable, Modular variable speed air handlers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Modular Variable Speed Air Handlers - Air …

1 ModularVariable SpeedAir Handlers4 TEE3F31B1000B4 TEE3F37B1000B4 TEE3F39A1000A4 TEE3F40B1000B4 TEE3F48B1000A4 TEE3F49C1000A4 TEE3F64A1000A4 TEE3F65B1000B4 TEE3F66A1000 APUB. NO. 22-1717-102 Pub. No. 22-1717-10 Optional EquipmentOPTIONAL EQUIPMENT FOR AIR Handlers (Check mark [ ] indicates accessories included).Plenum Pedestal (4 TEE3F37, 39, 40, 48, 49, 64, 65, 66).. TAYPLNM100 [ ]Sub-base For Downflow (4 TEE3F31).. TAYBASE101 [ ]Sub-base For Downflow (4 TEE3F37, 39, 48, 64).. TAYBASE100 [ ]Sub-base For Downflow (4 TEE3F40, 49, 65, 66).

2 TAYBASE102 [ ]Evaporator Defrost Control Kit Cooling Units (Low Ambient Cooling).. AY28X079 [ ]Evaporator Defrost Control Kit Heat Pumps (Low Ambient Cooling).. AY28X084 [ ]Knockout cover plate (4 TEE3F31, 37, 40, 49, 65, 66).. BAY99X123 [ ] BAYSTAT253 [ ]Featuresand Benefits Ships vertical - converts to horizontalby laying unit on side. Six-way convertibility horizontal (left& right), front & rear access; upflow,downflow Electrical, refrigerant, condensate &blower access convertible to eitherside Compact 21" depth for easy installation Variable Speed ECM motor , 4.

3 And 5 ton models availablein 26 widths or with VorticaTM widths Direct drive blower Comfort-R enhanced dehumidifica-tion cycle Soft Start - On cycle fan Speed isincreased gradually to reduce soundand drafts Corrosion resistant galvanized metalwith attractive finish Expansion valve refrigerant control Check valve for heat pump application Internally enhanced finned coil tubing External brazed refrigerant connec-tions Filter rack with standard size filter 200/230 volt primary & 24 voltsecondary transformer Low voltage terminal board Uses 1400 series heaters Access to heater circuit breakers Polarized plugs for making motor andtransformer electrical connections fromair handler control box to electricheaters Primary and secondary drain connec-tions Easy Air-TiteTM access to coils Built-in indoor fan delay function forincreased efficiency 4 TEE3F31 airflow selectable for1-1/2 3 ton unit 4 TEE3F37, 39, 40 airflow selectablefor 2 3-1/2 ton unit 4 TEE3F48, 49 airflow selectable for3 5 ton unit 4 TEE3F64, 65.

4 & 66 airflow selectablefor 3 5 ton unit Energy-saving continuous fan Enhanced cooling/heating control 2010 TraneNOTE: The 4 TEE3F48B, 4 TEE3F49C, and 4 TEE3F66A air Handlers should NOT be installed in the horizontal left or downflow configurations unless the outdoor unit has an AHRI rating with 18-GJ23D1 in the AHRI Directory. System ratings listedwithout 18-GJ23D1 are for horizontal right and upflow configurations only. The manufacturer recommends installing onlyapproved, matched indoor and outdoor No. 22-1717-103 ContentsFeatures and Benefits2 Optional Equipment2 Air-Tite Features and Benefits4 General Data54 TEE3F31B1000B54 TEE3F37B1000B54 TEE3F39A1000A54 TEE3F40B1000B54 TEE3F48B1000A54 TEE3F49C1000A64 TEE3F64A1000A64 TEE3F65B1000B64 TEE3F66A1000A6 Performance Data7 Electrical Data22 Field Wiring23 Convertibility24 Dimensions25 Mechanical Specification Options284 Pub.

5 No. 22-1717-10 Air-Tite Features and Benefits1 New Duct Flange Allows flush fit for 3/4", 1" or 11/2" Seal Exclusive Duct Flange Thermal Break/Seal and double wall construction to reduce cabinet loss " Foil Faced Insulation Thicker foil faced insulation forreduced cabinet loss, sweating and lower power Control Box Totally enclosed control box withtransformer inside to improve component life, unit durabilityand Resistant Screws Exclusive Weatherguard coated screws to maintain the quality appearance of the unitfor the life of the Panel Insulation Exclusive No Burn refrigerant coupling panel with thicker insulation for reducedheat Door Seal Improved door seal for reduced airinfiltration, heat transfer, and lower power Filter Door Filter is stamped on the panel, andincludes two captive screws with easy grip on Center Bar Exclusive center bar insulationfor reduced cabinet loss.

6 Sweating and lower power Gasket Exclusive formed gasket (similar to a cardoor gasket) to reduce air infiltration and heat transfer andlower power Circuit Breaker Door Easy access to breakerswith positive air SEER test for system efficiency places the air handler in theambient return air stream (80 F). If your air handler is to be in anunconditioned/severe climatic location you should consider theadvantages of the Air-Tite model air No. 22-1717-105 MODELRATED VOLTS/ 1 INDOOR COIL TypeRows Area (sq. ft.)Tube Size (in.)Refrigerant ControlDrain Conn.

7 Size (in.) 2 INDOOR FAN TypeDiameter-Width (In.)No. UsedDrive - No. SpeedsCFM vs. in. 1No. Motors Speed Amps - AmpsFILTERV ertical ApplicationsFilter Furnished?Type ApplicationsFilter Furnished?Recommended SizeREFRIGERANTRef. Line ConnectionsConn. Size in. GasConn. Size in. (In.)UncratedWEIGHTG eneralDataMODELRATED VOLTS/ 1 INDOOR COIL TypeRows Area (sq. ft.)Tube Size (in.)Refrigerant ControlDrain Conn. Size (in.) 2 INDOOR FAN TypeDiameter-Width (In.)

8 No. UsedDrive - No. SpeedsCFM vs. in. 1No. Motors Speed Amps - AmpsFILTERV ertical ApplicationsFilter Furnished?Type ApplicationsFilter Furnished?Recommended SizeREFRIGERANTRef. Line ConnectionsConn. Size in. GasConn. Size in. (In.)UncratedWEIGHT4 TEE3F31B1000B200-230/1/60 See SpecificationsPlate Fin3 - CopperTXV - NonBleed3/4 NPTC entrifugal10 x 81 Direct - 16 See Fan Performance Table1 1/2 Variable200-230/1 Velocity1 - 20 X 20 - 1 Note 34 R-410 ABrazed3/45/16H x W x D44-1/2 x 24 x 23-1/2 See Outline Drawing134 / 1184 TEE3F37B1000B200-230/1/60 See SpecificationsPlate Fin3 - CopperTXV - NonBleed3/4 NPTC entrifugal10 x 101 Direct - 16 See Fan Performance Table1 1/2 Variable200-230/1 Velocity1 - 20 X 20 - 1 Note 34

9 R-410 ABrazed3/43/8H x W x D47-7/8 x 26 x 23-1/2 See Outline Drawing142 / 1274 TEE3F39A1000A200-230/1/60 See SpecificationsPlate Fin3 - CopperTXV - NonBleed3/4 NPTC entrifugal11 x 101 Direct - 16 See Fan Performance Table1 1/2 Variable200-230/1 - 20 X 20 - 1 Note 34 R-410 ABrazed3/43/8H x W x D59-1/2 x 26 x 23-1/257-7/8 x 23-1/2 x 21160 / 1504 TEE3F48B1000A 5200-230/1/60 See SpecificationsPlate Fin3 - CopperTXV - NonBleed3/4 NPTC entrifugal11 x 101 Direct - 16 See Fan Performance Table1 3/4 Variable200-230/1 - 20 x 20 x 1 Note 34R-410 ABrazed3/43/8H x W x D59-1/2 x 26 x 23-1/257-7/8 x 23-1/2 x 21170/1551 These Air Handlers are certified withvarious Split System Air Conditioners andHeat Pumps (AHRI STANDARD 210/240).

10 Refer to the Split System Outdoor UnitProduct Data Guides for performance " Male Plastic Pipe (Ref.: ASTM 1785-76)3 Minimum filter size for horizontalapplications will be based on airflowselection and will be calculated as follows: Low Velocity Filter: Face area (Sq. Ft.) = CFM / 300 High Velocity Filter: Face area (Sq. Ft.) = CFM / 5004 For customer ease of filter maintenance, it isrecommended that a properly sized, remotefilter and grille be installed for horizontalapplications. Airflow should not exceed theface value of the filter being used.