LGCHEM SAFETY DATA SHEET SDS Page 1 of 16 Printed 19-9-49 Lithium-ion Rechargeable Battery Pack LG Chem, Ltd. MSDS for Dell Batteries. History Version. Items Description Date V01 Origin Initial Release V57 Reversion For 2017 V58 Update V60 Update Add Turis MLK V61 Update Add Whitehaven V62 Update For Iata 59th V63 Update Add Vancouver V64 Update Add project Marketing Name V65 Update Add Orion4C V66 Update Add Spyglass, Northbay, Merion project V67 Update Update Dell requested format V68 Update Add Brook Hollow, Forest creek V69 Update Add Mantis V70 Update Add Pinehill MLK, Modena, Olympic.

Oct 08, 2018 · Twin Tower Youido-Dong, Youngdeungpo-Ku Seoul, Korea Emergency Telephone Number 82-80-005-4000 2. Composition Information Hazardous Ingre dients % CAS Number Aluminum Foil 2-10 7429-90-5 ... Skin contact Wash area thoroughly with soap and water and seek medical attention. Ingestion

Tags:

  Twin, Skin

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MSDS for Dell Batteries.

1 LGCHEM SAFETY DATA SHEET SDS Page 1 of 16 Printed 19-9-49 Lithium-ion Rechargeable Battery Pack LG Chem, Ltd. MSDS for Dell Batteries. History Version. Items Description Date V01 Origin Initial Release V57 Reversion For 2017 V58 Update V60 Update Add Turis MLK V61 Update Add Whitehaven V62 Update For Iata 59th V63 Update Add Vancouver V64 Update Add project Marketing Name V65 Update Add Orion4C V66 Update Add Spyglass, Northbay, Merion project V67 Update Update Dell requested format V68 Update Add Brook Hollow, Forest creek V69 Update Add Mantis V70 Update Add Pinehill MLK, Modena, Olympic.

2 Riverside & IATA 60th LGCHEM SAFETY DATA SHEET SDS Page 2 of 16 Printed 19-9-49 The Attached SDS, accurately represents the chemical construction, of the Dell Batteries listed below. No. Dell Part Number Dell Type Number Capacity Rated voltage 1 N4 TXM/ WNJ9J XX1D1 36Wh 2 V0 XTF TKN25 49Wh 3 49 VTP MR90Y 65Wh 4 0MF69 MR90Y 65Wh 5 T1G4M XCMRD 40Wh 6 4 KFGD N3X1D 65Wh 7 5DN1K 71R31 97Wh 8 FT6D9 VJXMC 40Wh 9 NVWGM VV0NF 65Wh 10 Y6KM7 N5YH9 97Wh 11 Y9 HNT GVD76 31Wh 12 KR71X PFXCR 34Wh 13 J31N7 WD52H 45Wh 14 0D47W 34 GKR 47Wh 15 6 MYFW DGGGT 40Wh 16 FT6D9 VJXMC 40Wh 17 NVWGM VV0NF 65Wh 18 Y6KM7 N5YH9 97Wh 19 G4 YJM F7 HVR 58Wh 20 V3D9R 7 NXVR 21 CFC6C 7 WMM7 28Wh 22 PWM3D/TPVWW 5 MTD8 43Wh 23 3NG29/W7 KJC YFDF9 65wh 24 1V2F6 TRHFF 43Wh 25

3 DFVYN 0PD19 58Wh 26 0WF28 GK5KY 43Wh 27 9P4D2 RYXXH 38Wh 28 8V5GX G5M10 51Wh 29 WG6RP F3G33 39Wh 30 W57CV VFV59 52Wh 31 GV7HC V8XN3 40Wh 32 G95J5 3 RNFD 54Wh LGCHEM SAFETY DATA SHEET SDS Page 3 of 16 Printed 19-9-49 33 HFRC3 2H2G4 38Wh 34 FRVYX TM9HP 20Wh 35 YX81V 271J9 20Wh 36 2P9KD 3V806 51Wh 37 VTDT2 VMYGJ 58Wh 38 991XP M5Y1X 40Wh 39 RTC77 K185W 47Wh 40 FP02G JD33K 28Wh 41 70K80/7 VJMH T40JJ 42 H132V T40JJ 43 M9 XPM T40JJ 44 KTCCN 5R9DD 43Wh 45 WTG3T R0 TMP 62Wh 46 5PD40 K81RP 21Wh 47 242WD J60J5 54Wh 48 1V0PP T05W1 72Wh 49 RDYCT MFKVP 89Wh 50 RDRH9 NGGX5 47Wh 51 G9G1H WJ5R2 81Wh 52 92 NCT GK5KY 43Wh 53 2 VMGK N1WM4 62Wh 54 62 MJV RRCGW 56Wh 55 V55D0 7 VKV9 30W 56 VXT50 9KY50 19W 57 HK6DV 6MT4T 62Wh 58 2 VMGK N1WM4 62Wh 59 K5NN2 YFDF9 65wh 60 PKG3N 1 MCXM 28wh 61 5K9CP 90V7W 56Wh 62 K5NN2 GK5KY 43Wh 63 9JF93 TRHFF 43Wh 64 HMNKM 0PD19 58Wh 65 5 PYY9 RYXXH 38Wh 66 K9 GVN G5M10 51Wh 67 4H34M P63NY 43Wh 68 HMYXT/2P6GX T54FJ 60Wh 69 GK2X6 J1 KND 48Wh 70 T2JX4 WDX0R 42Wh LGCHEM SAFETY DATA SHEET SDS Page 4 of 16 Printed 19-9-49 71 81PF3 33 YDH 56Wh 72 H1391 W1193 60Wh 73 TVMVN/PFW7V T54FJ 60Wh

4 74 T453X 4 GVGH 84Wh 75 JNT6D 5R9DD 58Wh 76 05 VFW/9981K NHXVW 87Wh 77 RNP72 PW23Y 60Wh 78 NP0V3 NNF1C 46Wh 79 4 RRR3 TDW5P 76Wh 80 DWJHM VFV59 52Wh 81 CJW7D 3 RNFD 54Wh 82 96H67 Y2RV2 84 M6 WKR PWKWM 56Wh 85 5JT8G 1 WND8 86 X16TW J0 PGR 42Wh 87 546FF 44T2R 68Wh 88 01D82 9 NJM1 99Wh 89 NJJ2H J60J5 54Wh 90 J8 FXW 6MT4T 62Wh 91 C27RW DJ1J0 42Wh 92 2X39G F3 YGT 60Wh 93 MYJ96 F3 YGT 60Wh 94 5D91C H5H20 56Wh 95 5XJ28 6 GTPY 97Wh 96 96H67 Y2RV2 97 3VC9Y 3 DDDG 42Wh 98 83 XPC 93 FTF 51Wh 99 DV9NT GJKNX 68Wh 100 FPT1C GJKNX 68Wh 101 NY5PG VG93N 92Wh 102 FTG78 J0 PGR 42Wh 103 725KY K5 XWW 60Wh 104 CFX97 71TG4 45Wh 105 V57XN/YCNCW M5Y0X 97Wh 106 J7 KGM/3 CVD9 M5Y0X 97Wh 107 8 PGNG JWPHF 57Wh 108 P27T3 R795X 84Wh 109 6K0DT H7XW1 44WH LGCHEM SAFETY DATA SHEET SDS Page 5 of 16 Printed 19-9-49 110 YKF0M 8858X 48Wh 111 X28XH X284G 48Wh 112 3N73J GW240 32Wh 113 KCFPM TKV2V 48Wh 114 H1391/ 3XY6Y W1193 62Wh 115 8 TJD2/ 9X6X0 W1193 62Wh 116 9 GXD5/ CWTM0 RFJMW 97Wh 117 6 CYH6 K5 XWW 60Wh 118 Y07HK 51KD7 42Wh 119 C07K7 WJ5R2 81Wh 120 MN791 271J9 20Wh

5 121 R89JJ TM9HP 20Wh 122 242WD J60J5 54Wh 123 K5NN2 YFDF9 65wh 124 0C178 NGGX5 47Wh 125 0D074 6MT4T 62Wh 126 K1G3K WJ5R2 81Wh 127 4 RRR3 TDW5P 76Wh 128 546FF 44T2R 68Wh 129 6 CYH6 K5 XWW 60Wh 130 8 YPRW WDX0R 42Wh 131 99NF2 33 YDH 56Wh 132 5JT8G 1 WND8 133 X16TW J0 PGR 42Wh 134 FTG78 J0 PGR 42Wh 135 Y07HK 51KD7 42Wh 136 1 GGDK 33 YDH 56Wh 137 8 YPRW WDX0R 42Wh 138 99NF2 33 YDH 56Wh 139 H754V DXGH8 52Wh 140 V5 MHM 8N0T7 75Wh 141 7PY0D M5Y1K 40Wh 142 H6K6V 5TF10 64Wh 143 7M0T6 NYFJH 97Wh 144 FY2VW NYFJH 97Wh 145 GK3D3/6 NNCF 7 WNW1 51Wh LGCHEM SAFETY DATA SHEET SDS Page 6 of 16 Printed 19-9-49 146 FDRHM YRDD6 42Wh 147 8622M 1F22N 60Wh 148 8W3YY NF2MW 52Wh 149 C7P81 NF2MW 52Wh 150 C76H7 7146W 78Wh 151 XV8CJ 1V1XF 42Wh 152 49HG8 R8D7N 51Wh 153 X77XY 4 GVMP 68Wh 154 5H46R 4 GVMP 68Wh 155 3KF82 0G74G 42Wh 156 829MX MXV9V 60Wh 157 CR8V9 MXV9V 60Wh 158 10X1J/3 YNXM 3 HWPP 68Wh 159 1 WJT0 1 FXDH 97Wh 160 07 GDY JPFMR 42Wh 161 415CG 266J9 51Wh 161 9P3NW/G4MX4 4WN0Y 56Wh 162 2 XXFW 722KK 52Wh 163 8 NFC7 N7HT0 52Wh 164 09 YYF 35J09 39Wh 165 4V5X2/YY3GJ JHT2H 52Wh LGCHEM SAFETY DATA SHEET

6 SDS Page 7 of 16 Printed 19-9-49 MATERIAL SAFETY DATA SHEET Lithium-Ion Battery LG Chem, Ltd. 1. Chemical Product and Company Identification Product Identification Lithium-Ion Battery ( All models manufactured by LG Chem, Ltd ) Manufacturer LG Chem, Ltd. twin Tower Youido-Dong, Youngdeungpo-Ku Seoul, Korea Emergency Telephone Number 82-80-005-4000 2. Composition Information Hazardous Ingredients % CAS Number Aluminum Foil 2-10 7429-90-5 Metal Oxide (proprietary) 20-50 12190-79-3 Polyvinylidene Fluoride (PVDF) <5 24937-79-9 Copper Foil 2-10 7440-50-8 Carbon (proprietary) 10-30 7440-44-0 Electrolyte (proprietary) 10-20 21324-40-3 Stainless steel, Nickel and inert materials Remainder N/A LGCHEM SAFETY DATA SHEET SDS Page 8 of 16 Printed 19-9-49 3.

7 Hazards Identification Primary routes of entry skin contact : NO skin absorption : NO Eye contact : NO Inhalation : NO Ingestion : NO Symptoms of exposure skin contact No effect under routine handling and use. skin absorption No effect under routine handling and use. Eye contact No effect under routine handling and use. Inhalation No effect under routine handling and use. Reported as carcinogen Not applicable Emergency Overview May explode in a fire, which could release hydrogen fluoride gas. Use extinguishing media suitable for materials burning in fire.

8 LGCHEM SAFETY DATA SHEET SDS Page 9 of 16 Printed 19-9-49 4. First Aid Measures Inhalation Not a health hazard. Eye contact Not a health hazard. skin contact Not a health hazard. Ingestion If swallowed, obtain medical attention immediately. IF EXPOSURE TO INTERNAL MATERIALS WITHIN CELL DUE TO DAMAGED OUTER CASING, THE FOLLOWING ACTIONS ARE RECOMMENDED ; Inhalation Leave area immediately and seek medical attention. Eye contact Rinse eyes with water for 15 minutes and seek medical attention. skin contact Wash area thoroughly with soap and water and seek medical attention. Ingestion Drink milk/water and induce vomiting;seek medical attention.

9 LGCHEM SAFETY DATA SHEET SDS Page 10 of 16 Printed 19-9-49 5. Fire Fighting Measures General Hazard Cell is not flammable but internal organic material will burn if the cell is incinerated. Combustion products include, but are not limited to hydrogen fluoride, carbon monoxide and carbon dioxide. Extinguishing Media Use extinguishing media suitable for the materials that are burning. Special Firefighting Instructions If possible, remove cell(s) from fire fighting area. If heated above 125 C, cell(s) may explode/vent. Firefighting Equipment Use NIOSH/MSHA approved full-face self-contained breathing apparatus (SCBA) with full protective gear.

10 6. Accidental Release Measures On Land Place material into suitable containers and call local fire/police department. In Water If possible, remove from water and call local fire/police department. 7. Handling and Storage Handling No special protective clothing required for handling individual cells. Storage Store in a cool, dry place. LGCHEM SAFETY DATA SHEET SDS Page 11 of 16 Printed 19-9-49 8. Exposure Controls / Personal Protection Engineering controls Keep away from heat and open flame. Store in a cool dry place. Personal Protection Respirator Not required during normal operations.