Example: barber

Neo-Ray Converge S920/S921 Specification Sheet

DESCRIPTIONC atalog #ProjectCommentsPrepared byTypeDateSPECIFICATION FEATURES01/14/2019 Speci cations and dimensions subject to change without additional information on the following INFORMATIONS ample Number: S920 DIP-W335-PT12S4-UDD-WPS524038EN1 of 5 Neo-RaySee page 5 for Technical NotesSeriesOpticsLight Level @ 3500K 5 (Nominal Lms / 4 section)CCTC eiling TypeRow Length 1, 6 Linear ConfigurationsS920 DIP = Rectilinear Direct / Indirect PendantS921 DIP = CurvilinearDirect / Indirect Pendant-W = Wavestream Up 40% / Down 60% 1 = Light Level 1 (2100 lm) 12 = Light Level 2 (3200 lm) 13 = Light Level 3 (4300 lm) 14 = Light Level 4 (5400 lm) 15 = Light Level 5 (6500 lm) 130 = 3000K35 = 3500K40 = 4000K 85 CRI = On-Grid (includes teg)-PT = Pierced Tile Grid-SF = Sheet Rock Flush (Mud Flange)

DESCRIPTION Catalog # Project Comments Prepared by Type Date SPECIFICATION FEATURES 08/28/2017 Speci≥cations and dimensions subject to change without notice.

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Neo-Ray Converge S920/S921 Specification Sheet

1 DESCRIPTIONC atalog #ProjectCommentsPrepared byTypeDateSPECIFICATION FEATURES01/14/2019 Speci cations and dimensions subject to change without additional information on the following INFORMATIONS ample Number: S920 DIP-W335-PT12S4-UDD-WPS524038EN1 of 5 Neo-RaySee page 5 for Technical NotesSeriesOpticsLight Level @ 3500K 5 (Nominal Lms / 4 section)CCTC eiling TypeRow Length 1, 6 Linear ConfigurationsS920 DIP = Rectilinear Direct / Indirect PendantS921 DIP = CurvilinearDirect / Indirect Pendant-W = Wavestream Up 40% / Down 60% 1 = Light Level 1 (2100 lm) 12 = Light Level 2 (3200 lm) 13 = Light Level 3 (4300 lm) 14 = Light Level 4 (5400 lm) 15 = Light Level 5 (6500 lm) 130 = 3000K35 = 3500K40 = 4000K 85 CRI = On-Grid (includes teg)-PT = Pierced Tile Grid-SF = Sheet Rock Flush (Mud Flange)

2 -SR = Sheet Rock with proud cover plate-ST = Structure Mount 4 = 4 Individual8 = 8 IndividualXXX = Specify row length in 4 incrementsS = StandardB = Balanced 1, 8* Please refer to config. table on page 4 for valid configurationsCable Mounting CentersVoltageDriver OptionsFinish 11 Integral Emergency 8 Downlight Kits 8 Options 82 = 24 4 = 48 (Standard)8 = 96 (8 Individual Only) * Please refer to config. table on page 4 for valid configurations-U = Universal 120-277 VAC-1 = 120 VAC-2 = 277 VAC-3 = 347 VAC 3-48 = 48 VDC 4DD = Standard 0-10V (10%-100%)HCD = 0-10V (1%-100%) 1, 8 DCD = 0-10V (.1%-100%) 1, 85 LT = Fifth Light DALI (10%-100%) 1, 85 LTHD = Fifth Light DALI (.)

3 1%-100%) 1, 8 STP = Step Dim 1, 8L5 = Lutron LDE5 w/ Ecosys 1, 8LH = Lutron LDE1 w/ Ecosys 1, 8 DD3 = 347V 0-10 (5%-100%) 1, 3, 8LV 1 = DLVP Driver 1, 4, 8-W = White-S = Silver-B = Black-C = Custom Color 8-EL7W = Integral Battery Pack 2-EL14W = Integral Battery Pack 2-GTD2 = Generator Transfer Device 2-PC = Perf Cover -SC = Solid Cover (100% down)CP = Chicago plenumLWTPD1 = Tilemount Lumawatt Pro Wireless Sensor 7cULus 1598IC RatedDamp Location ListedLM79/LM80 CompliantROHS Compliant WaveStream LED SuspendedDirect / IndirectCONVERGEC onstructionHousing trim extruded from 6063 aluminum.

4 Nominal 4 and 8 sections. Used in run configuration and/or individual fixtures. All components are RoHs optical grade acrylic embeddedwith patented WaveStreamAccu-Aim optics for optimaldistribution, excellent uniformity,and high performance. Light engine becomes virtually clear inthe housing trims are finished with an electrostatically applied polyester powder coat paint for long lasting , Pierced-Tile, Surface, Sheetrock and Flangless LED system powered by aremote driver through low-voltage aircraft cable to deliver optimal performance. LED s are available in 3000K, 3500K or 4000K with a typical CRI 85. Projected life is 193k hours at 70% lumen output for most configurations. Electronic drivers are available for 120-277V and 347V applications.

5 ControlsEquipped standard with a 0-10V continuous dimming driver compatible with most standard dimming devices (refer to website for specific compatibility reference). Combine with FifthLight DALI and other energy saving products like sensors, daylighting controls and building management systems to maximize energy savings. ComplianceFixtures and electrical components certified to UL and CUL standards. Fixtures are damp location listed and IC rated. For Chicago plenum, specify CP in fixture year warranty. The Converge series by Neo-Ray defines the new standard in ambient lighting by combining the highest degree of minimization with the most advanced optical distribution and control available.

6 Eaton s LuxWire technology delivers low-voltage power to the luminaire through the same cables from which it is suspended, allowing the luminaire to float beautifully in space without large, unsightly power cables. Our patented next generation curved WaveStream light engine coupled with a proprietary light mixing chamber (patent pending) enables you to bend uniform light like never before. Luminaires are specifiable in 4 foot increments with a variety of mounting op-tions. Adaptable and modular components make installation simple and ensure laser straight runs. [ ] RectilinearS921 DIP Curvilinear01/14/2019 Speci cations and dimensions subject to change without additional information on the following E.

7 Colfax AvenueDenver, CO 80011P: 303-393-1522 PS524038EN2 of 5 Neo-Ray - ConvergeLUMEN MAINTENANCE @ 25 CLUMEN PACKAGE DETAIL (3500K) Fixture LengthLight LevelTotal Lumen Output (lms)Power Con-sumption (W)Efficacy (LPW)4 Driver, Data from Test Reports P210488-P210492 FILE NAME: S920 DIP-W235-XX4XX-UDD-WCCT: 3500 KLUMENS: 3239 LmsWATTS: WLPW: LPWTEST NUMBER: P210489 FILE NAME: S920 DIP-W435-XX4XX-UDD-WCCT: 3500 KLUMENS: 5427 LmsWATTS: WLPW: LPWTEST NUMBER: P210491 All data certified to LM-79 standards in a NAVLAB approved testing facilityLight LevelTM-21 Lumen Maintenance (60,000 hours)Theoretical L70(Hours)1, 2, 3, , ,000 ZONAL LUMEN STUDYLUMINANCE DATA (cd / )ZoneLumens% FixtureVertical Angle0 45 90 0 -30 45 2282173315930 -40 2195151913980 -60 65 209611 8 7111 40 -90 183476658090 -180 11 6 29312564 ZONAL LUMEN STUDYLUMINANCE DATA (cd / )

8 ZoneLumens% FixtureVertical Angle0 45 90 0 -30 3824290426690 -40 3678254623420 -60 65 3512198918660 -90 3072128497190 -180 1946156142960 30 60 90 15 45 75 120 150 180 105 135 165 0-deg90-deg6715033351680 30 60 90 15 45 75 120 150 180 105 135 165 0-deg90-deg1,12484356228101/14/2019 Speci cations and dimensions subject to change without additional information on the following E. Colfax AvenueDenver, CO 80011P: 303-393-1522 of 5 DIMENSIONSNeo-Ray - Converge - Flangeless Sheet RockSR - Sheet RockST - StructurePT - Pierced TileGD - GridUniversal Grid ClipUniversal Grid Hanger BarContinuous RunMOUNTING Row Length (ft) x 12 + Row Length (ft) x + Row Length (ft) x 12 Row Length (ft) x LengthConfiguration ChartPT - Pierced TileGD - GridLength Code 8S48 Individual Fixture4 Mounting CentersLength Code 4S24 Individual Fixture2 Mounting Centers01/14/2019 Speci cations and dimensions subject to change without additional information on the following E.

9 Colfax AvenueDenver, CO 80011P: 303-393-1522 CONFIGURATION CHARTPS524038EN4 of 5 Neo-Ray - Converge8 Luminaire4 Driver box configuration2 Driver box configuration2 Driver box configuration (standard), 4' with internal battery4 Luminaire4 Standard 4 4S44 Standard 2 4S28 Standard 4 8S412 Balanced 2 12B212 Standard 4 12S416 Standard 4 16S420 Standard 4 20S424 Standard 4 24S428 Standard 4 28S432 Standard 4 32S436 Standard 4 36S440 Standard 4 40S448 Standard 4 48S452 Standard 4 52S456 Standard 4 56S464 Standard 4 64S460 Balanced 4 60B468 Standard 4 68S4 Linear Config. Length Mounting Centers (ft)LengthCode44 Balanced 4 44B4 Fixture and Remote Box Layout28 Balanced 4 28B444 Standard 4 44S460 Standard 4 60S48 Standard 8 8S88 Mounting Centers only available on individual 8 length with GD and PT InstallationNote:For Grid & Pierced Tile Mount - Driver box length will default to 2 feet for single driver configurations without an emergency section.

10 Please consult driver table on page cable drop 9 Double cable drop 901/14/2019 Speci cations and dimensions subject to change without additional information on the following E. Colfax AvenueDenver, CO 80011P: 303-393-1522 TABLENeo-Ray - ConvergePS524038EN5 of 5 TECHNICAL NOTES# of Drivers4 Fixture (Light Level)8 Fixture (Light Level)Driver TypeL1L2L3L4L5L1L2L3L4L5DD1111111122 HCD111121122N/ADCD111121122N/A5 LT11111111225 LTHD111121122N/ASTPN/AN/A1111122N/ALUE11 1N/AN/A122N/AN/ALUL111N/AN/A122N/AN/ALH1 111111122L51111N/A11N/A2N/ADD31111111222 LV 11111111222 1) Consult driver table for valid Driver & Light Level configurations. 2) EL7W, EL14W and GTD2 require Voltage selection 1 = 120 VAC or 2 = 277 VAC.


Related search queries