Newport Medical instruments , VENTILATORS ervice ManualSER360 , Sunflower AvenueCosta Mesa, CA92626 USATel: : (USA only)Fax: Service ext. OF CONTENTSS ection 2 ..MAINTENANCE, OVERHAUL& SOFTWARE UPGRADES ection 3 ..TROUBLESHOOTING GUIDES ection 4 ..COMPONENT REMOVAL& REPLACEMENTS ection PROCEDURESS ection VERIFICATIONPROCEDURES ection 7 ..CLEANING and MAINTENANCE Appendix OPERATIONA ppendix CONTACTINFORMATIONA ppendix C ..DIAGRAMSSER360 A11061. INTRODUCTIONI ntroduction .. 1-1 Definitions .. 1-1 General 1-1 General Cautions .. 1-2 Warranty .. 1-2 Factory 1-3 Copyright Information .. 1-3 Contact Information .. 1-3 SER360 A1106 INTRODUCTIONIt is very important to read and understand all of the information inthis manual before attempting to service the e360 review all warnings and cautions in this manual beforeattempting to service the e360 WARNING describes a condition that can causepersonal Caution describes a condition tha

Newport Medical Instruments, Inc. NEWPORT e360 VENTILATOR Service Manual SER360 Rev. A 11/06 NEWPORT MEDICAL INSTRUMENTS, INC. 1620 Sunflower Avenue Costa Mesa, CA92626 USA

Tags:

  Medical, Instruments, Ventilator, Newport, Newport medical instruments

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Newport Medical Instruments, Inc. N e360 …

1 Newport Medical instruments , VENTILATORS ervice ManualSER360 , Sunflower AvenueCosta Mesa, CA92626 USATel: : (USA only)Fax: Service ext. OF CONTENTSS ection 2 ..MAINTENANCE, OVERHAUL& SOFTWARE UPGRADES ection 3 ..TROUBLESHOOTING GUIDES ection 4 ..COMPONENT REMOVAL& REPLACEMENTS ection PROCEDURESS ection VERIFICATIONPROCEDURES ection 7 ..CLEANING and MAINTENANCE Appendix OPERATIONA ppendix CONTACTINFORMATIONA ppendix C ..DIAGRAMSSER360 A11061. INTRODUCTIONI ntroduction .. 1-1 Definitions .. 1-1 General 1-1 General Cautions .. 1-2 Warranty .. 1-2 Factory 1-3 Copyright Information .. 1-3 Contact Information .. 1-3 SER360 A1106 INTRODUCTIONIt is very important to read and understand all of the information inthis manual before attempting to service the e360 review all warnings and cautions in this manual beforeattempting to service the e360 WARNING describes a condition that can causepersonal Caution describes a condition that can causedamage to :A NOTE emphasizes information that is important :examination of actual :measures to maintain specified :measures to restore to specified :inspection, service, and repair where Maintenance:maintenance performed at Verification:a routine verification procedure toensure proper Procedure.

2 A procedure for replacing key componentsat regular intervalsGENERALWARNINGSP lease review all warnings and cautions in this manual beforeattempting to service the and Cautions appear throughout this manual where theyare relevant. The Warnings and Cautions listed here applygenerally any time you work on the 1 SER360 A11061-1 WARNINGTo maintain grounding integrity, connect only to a hospitalgrade receptacle. Always disconnect power supply beforeservicing the e360 :there is a risk of explosion if used in the presence offlammable returning to patient use, the e360 ventilator must passthe operational verification e360 ventilator service or repair must be performed by atechnician authorized and trained by Newport extreme caution when working inside the e360 ventilatorwhile it is connected to a power CAUTIONSC autionUse standard antistatic techniques when working inside thee360 ventilator or handling any electronic all external parts of the e360 ventilator prior to only dry.

3 Clean compressed air and Medical grade in the air or oxygen supply can cause equipmentmalfunction and voltage must correspond to the voltage range selectedon the power module of the e360 ventilator . Always replace anopen fuse with one of correct type and not place containers of liquids near the e360 that get into the e360 ventilator can cause equipmentmalfunction or :Use the tools specified in the manual to perform e360 ventilator comes with a two (2) year warranty covers any defect or malfunction thatoccurs due to normal use. The warranty does not cover anyINTRODUCTION1-2 SER360 A1106scheduled maintenance. See the e360 ventilator OperatingManual for the conditions of this Law in the United States requires traceability of thisequipment.

4 Please fill out the self-addressed Warranty RegistrationCard included with the product and return it to Newport register online at SERVICES cheduled maintenance or repair services are available from theNewport Technical Service department. See Appendix B forinstructions on returning your ventilator for service. Newport sannual price list includes current pricing for scheduledmaintenance and labor rates. To obtain a copy of the price list,please contact your local Newport representative or contact ourCustomer Service INFORMATIONC opyright 2006 Newport Medical instruments , Inc. all rightsreserved. The Newport e360 ventilator system is manufactured inaccordance with Newport Medical instruments , Inc.

5 Proprietaryinformation and is covered by the following Patent, #6,439, information in this manual is the sole property of NewportMedical instruments , Inc. and may not be duplicated withoutpermission. This manual may be revised or replaced by NewportMedical instruments at any time and without INFORMATIONA ddress: Newport Medical Instruments1620 Sunflower AvenueCosta Mesa, California, USA 92626 Phone numbers:Toll-free within the United States: : numbers:Main Fax: Service Fax: 1 SER360 A11061-3 DepartmentCustomer Service: 282extensions:Technical Service: 500 (24-hour pager activated)Clinical Support: 123 (24-hour pager)Corporate OfficeMonday through Friday, 8:00 am to 5:00 pm hours:(USA Pacific Time)EU Representative: Newport Medical InstrumentsAtt.

6 Robert Brinkc/o Braun & Pasture LincolnshireDN18 5 HN, Englandtel: ++ 68 231311 Fax: ++ A11062. MAINTENANCE, OVERHAUL& SOFTWARE UPGRADEM aintenance & Overhaul 2-1 General 2-1 General Cautions .. 2-2 Parts Required / Tools Required .. 2-2 Maintenance Procedures .. 2-3 Inlet Water Trap Filters & O-rings Assembly 2-3 Exhalation Valve Exhalation Valve Diaphragm, Seal& O-Ring .. 2-5 Emergency Relief Diaphragm .. 2-5 Overhaul Procedures .. 2-6 Inlet Water Trap Filters & O-rings Assembly2-6 Air and Oxygen Inlet Regulator Rebuild .. 2-7 Exhalation Valve Adapter .. 2-7 Exhalation Valve 2-8 Cooling Fan Filter & Guard.

7 2-8 Emergency Relief Diaphragm .. 2-9 Emergency Intake Diaphragm .. 2-9 Inhalation Outlet Check 2-10 Internal Battery .. 2-10 Tubing .. 2-10 Software Upgrade Information .. 2-11 Upgrade 2-11 Circuit Test & Diagnostic .. 2-13 Software Upgrade Form .. 2-19 SER360 A1106 MAINTENANCE & OVERHAUL INTERVALSThe Level I Preventive Maintenance procedure should beperformed once a year or every 5000 hours, whichever comes the Level 2 Overhaul Procedure, every 5 years or 25,000hours, whichever comes WARNINGSWARNINGAll servicing or repair of the e360 ventilator must be carried outoff voltages are present inside the e360 ventilator . Useextreme caution if it is necessary to work inside the ventilatorwhile it is connected to a power source.

8 Disconnect electricalpower, air and oxygen sources before attempting anydisassembly. Failure to do so could result in injury to servicepersonnel or maintain grounding integrity, the e360 ventilator must beconnected to a hospital grade receptacle when in :There is a risk of explosion if the e360 ventilator isused in the presence of flammable returning to patient use, the e360 ventilator must passthe Operational Verification service repairs of the e360 ventilator must be performed bya service technician authorized and trained by Newport prevent damage from ESD and possible failure of the e360ventilator, use standard anti-static techniques when workinginside the e360 ventilator , handling circuit boards or otherelectronic 2 SER360 A11062-1 GENERAL CAUTIONSC autionClean all external parts of the e360 ventilator prior to only dry.

9 Clean compressed air and Medical grade in the air or oxygen supply can cause ventilatormalfunction or voltage must correspond to the voltage range specifiedon the e360 ventilator Power Entry Module. Always replacefuses with those of correct type and all liquids away from the e360 ventilator . Liquids in thee360 ventilator can cause malfunction or use standard antistatic techniques when working insidethe e360 ventilator or handling any electronic REQUIREDNOTE:Use the tools specified in the manual to perform specificprocedures. Large Phillips screwdriver Medium Phillips screwdriver Needle Nose pliersPARTS REQUIREDP reventive Maintenance KitThe Preventive Maintenance Kit (PMK360A) includes the followingitems:MAINTENANCE, OVERHAUL & SOFTWARE UPGRADEPart NumberQuantityDescriptionJFK100P2 JAR Filter Kit ADP2105M1 Exhalation Valve Adapter DIA1800M1 Emergency Relief DiaphragmSEL1800M1 Exhalation Valve SealORG1200P1O-Ring, Exhalation Flow SensorDIA1810M1 Exhalation Valve Diaphragm2-2 SER360 A1106 Overhaul KitThe Overhaul Kit (OVL360A) includes the following items:MAINTENANCE PROCEDURESWARNING.

10 Disconnect electrical power, air and oxygensources before attempting any Water Trap Filters & O-ring AssemblyFigure 2-1 Inlet Water Trap Filter Replacement1 Unscrew the collection bowl from the inlet water the filter 2 Part NumberQuantityDescriptionJFK100P2 JAR Filter KitRRK1800P2 Regulator Rebuild KitGRD1800P1 Cooling Fan Filter & GuardADP2105M1 Exh. Valve Adapter PPT1805A1 Exh. Valve Dia & Poppet AssyORG1200P1O-Ring, Exhalation Flow SensorDIA1800M1 Emergency Relief DiaphragmVLV100P1 Emergency Intake DiaphragmVLV2100M1 Inhalation Outlet Check Valve DiaphramBAT1800P1 Internal BatterySER360 A11062-33 Remove and replace the inlet filter and the filter holder and reassemble the water trap 2-2 Exhalation Valve Adapter Replacement1 Access the Exhalation Valve Adapter by lifting the Retaining Latch and removing the Exhalation Valve and Exhalation Flow Sensor, see Figure 2-2 remove the silicon Exhalation Valve Adapter, use your fingerto grasp the Adapter and pull it straight out.