Transcription of Non-Loadbearing Timber Stud - Gyproc
1 C04 Non-Loadbearing Timber studPartitionsNon-loadbearing Timber studTraditional stud partitionsC04. S11. P275 ROI: 1800 744480 NI: 0845 3990159 Timber studPartitionsNon-loadbearing Timber studTimber stud partitions provide basic space division where speed of installation is considered to be a lower priority. A wide range of performances are available depending upon the specification of Gyproc linings, Gypframe metal components and Isover benefits High levels of acoustic performance are achievable through the use of a range of upgrades to the basic Timber framework including Gypframe RB1 Resilient Bar.
2 Gyproc SoundBloc and Isover Acoustic Roll Can achieve up to 2 hours fire resistance through the use of Gyproc FireLine plasterboardYou may also be interested quiet If you re looking for solutions with a higher level of acoustic and fire performance for use as a separating wall in a residential building, or other more onerous situations Refer to C04. S07. P219 GypWall you re looking for a Duty Rating in accordance with BS 5234: Part 2: 1992 Refer to C04. S01. P108 Partitions performance dBC04. S11. P276 Timber studPartitions123 DetailPartition thickness mmBoard typeLining thicknessmmStud sizemm1 Sound insulation RwdBSystem referenceNo insulationWith insulation30 minutes fire resistance 188 Gyproc SoundBloc1 x x 38-402A026009193 Gyproc SoundBloc1 x 1563 x 3840-A026008193 Gyproc WallBoard1 x 1563 x 38-402A0260101105 Gyproc WallBoard1 x 1575 x 3837402A026002/61105 Gyproc SoundBloc1 x 1575 x 3840432A026014/1760 minutes fire resistance 2115 Glasroc F multiboard2 x 1075 x 3838-G1060042125 Gyproc FireLine2 x x 3838422A026028/93196 Gyproc SoundBloc2 x 1575 x 38-52A0540290 minutes
3 Fire resistance 2125 Glasroc F multiboard2 x x 3837-G1060052135 Gyproc FireLine2 x 1575 x 3838422A026030/1 For further assistance in choosing the right solution for your project, try our System Selector; an online tool that enables quick and easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to Stud sizes quoted are 25mm Isover Acoustic Roll insulation. The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to Gyproc s recommendations.
4 The quoted performances are achieved only if Gyproc and Isover components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with layer of board each side of Timber studs at 600mm centres. Insulation and linings as in treatment on one side of existing plasterboard partition (minimum 1 x plasterboard each side of 75mm x 38mm studs at 600mm centres) using 50mm x 50mm Timber battens at 600mm centres, 50mm Isover Acoustic Roll between the studs with Gypframe RB1 Resilient Bar at 600mm centres (fixed horizontally).
5 Linings as in layers of board each side of Timber studs at 600mm centres. Insulation and linings as in Timber stud performance63mm and 75mm Timber stud partitionsTable 1a Solutions to satisfy the requirements of BS EN 1364-1: 1999 ( Non-Loadbearing )For details of when to specify fire resistance using EN Refer to C02. S01. P18C04. S11. P277 ROI: 1800 744480 NI: 0845 3990159 Timber studPartitions1234 One layer of board each side of Timber studs at 600mm centres. Insulation and linings as in treatment on one side of existing plasterboard partition (minimum 1 x plasterboard each side of 75mm x 38mm studs at 600mm centres) using 50mm x 50mm Timber battens at 600mm centres, 50mm Isover Acoustic Roll between the studs with Gypframe RB1 Resilient Bar at 600mm centres (fixed horizontally).
6 Linings as in layers of board each side of Timber studs at 600mm centres. Insulation and linings as in layer of board each side of Timber studs at 600mm centres and 65mm Isover Acoustic Roll in the cavity. Linings as in Timber stud performance (continued)63mm, 75mm and 100mm Timber stud partitionsTable 1b Solutions to satisfy requirements of BS 476: Part 22: 1987 ( Non-Loadbearing ) For further assistance in choosing the right solution for your project, try our System Selector; an online tool that enables quick and easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects.
7 Go to Stud sizes quoted are 25mm Isover Acoustic Roll insulation. The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to Gyproc s recommendations. The quoted performances are achieved only if Gyproc and Isover components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with thickness mmBoard typeLining thicknessmmStud sizemm1 Sound insulation RwdBSystem referenceNo insulationWith insulation30 minutes fire resistance 188 Gyproc SoundBloc1 x x 38-402A026009488 Gyproc WallBoard1 x x 38-41A026012193 Gyproc SoundBloc1 x 1563 x 3840-A026008193 Gyproc WallBoard1 x 1563 x 38-402A0260101100 Gyproc WallBoard1 x x 3835362A026001/0051100 Gyproc SoundBloc1 x x 3838402A026011/0161105 Gyproc SoundBloc1 x 1575 x 3840432A026014/01760 minutes fire resistance 1100 Glasroc F multiboard1 x x
8 5034-G1060032115 Glasroc F multiboard2 x 1075 x 5038-G1060042125 Gyproc WallBoard2 x x 3838422A026003/0072125 Gyproc SoundBloc2 x x 3844462A026015/0181130 Gyproc FireLine1 x 15100 x 5038-A0260233196 Gyproc SoundBloc2 x 1575 x 38-52A0540290 minutes fire resistance 2125 Glasroc F multiboard2 x x 3837-G106005120 minutes fire resistance 2160 Gyproc FireLine2 x 15100 x 5041-A026025 For details of when to specify fire resistance using BS Refer to C02. S01. P18C04. S11. P278 Timber studPartitions123 DetailPartition thickness mmBoard typeLining thicknessmmStud sizemmSound insulation Rw (Rw+ Ctr)dBSystem reference60 minutes fire resistance 2141 Gyproc SoundBloc2 x x 3856 (48)A0460053157 Gyproc SoundBloc2 x x 3859 (51)A0460061293 Gyproc Plank + Gyproc FireLine1 x 19 + 1 x x 3863 (51)A036003 For further assistance in choosing the right solution for your project, try our System Selector; an online tool that enables quick and easy filtering by performance criteria.
9 It provides system specific information downloads including BIM (Revit) objects. Go to The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to Gyproc s recommendations. The quoted performances are achieved only if Gyproc and Isover components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with separate Timber frames spaced 50mm apart, consisting of 89mm x 38mm Timber studs at 600mm centres with noggings.
10 Two layers of board each side. 100mm Isover Acoustic Roll between the studs on one side. Linings as in layers of board each side of 75mm x 38mm Timber studs at 600mm centres with Gypframe RB1 Resilient Bars fixed horizontally to both sides at 600mm centres. 50mm Isover Acoustic Roll in the cavity. Linings as in layers of board each side of 75mm x 38mm Timber studs at 600mm centres with Gypframe RB1 Resilient Bars fixed horizontally to one side at 600mm centres. 50mm Isover Acoustic Roll in the cavity. Linings as in Timber stud performance (continued)75mm and 89mm Timber stud wallsTable 2a Solutions to satisfy the requirements of BS EN 1364-1: 1999 ( Non-Loadbearing )For details of when to specify fire resistance using EN Refer to C02.