Example: stock market

NON-SHRINK GROUTING 03 62 00 - QUIKRETE

1. Product NameQUIKRETE NON-SHRINK precision Grout #1585-002. ManufacturerThe QUIKRETE CompaniesOne Securities Centre3490 Piedmont Rd., NE, Suite 1300 Atlanta, GA 30305(404) 634-9100 Fax: (404) Product DescriptionBASIC USET ypical applications for QUIKRETE Non-ShrinkPrecision Grout include GROUTING of: All types of machinery Steel columns Bearing plates Precast concrete Other anchoring conditions that requirehigh in-service strengthThe nonshrink characteristics of Non-ShrinkPrecision Grout make it stable and capable ofhandling high load & MATERIALSQUIKRETE NON-SHRINK precision Grout is a non-metallic Portland cement based precision Grout is a preblendedproduct including expansive additives, requiringonly the addition of water to obtain flowableproperties and high 50 lb ( kg) bagsCOLORS GrayYIELDA 50 lb ( kg) bag of QUIKRETE Non-ShrinkPrecision Grout will yield cu ft ( L) atflowable proper cleaning and wetting of surfaces tobe grouted is vital to maximum and cold temperature precautions, as theyapply to concrete, should also be Technical DataAPPLICABLE STANDARDSASTM International ASTM C109/C109M Standard Test Method forCompressive Strength of Hydraulic CementMortars (Using 2-in.)

QUIKRETE Non-Shrink Precision Grout should be mechanically mixed for a minimum of 5 minutes. PRECAUTIONS Add the minimum amount of water necessary to produce the desired flow characteristics as indicated in Table 2. Do not exceed a flow of 20 seconds per ASTM C939. METHODS Surfaces to receive the grout must be clean NON-SHRINK GROUTING 03 62 00

Tags:

  Flows, Precision, Shrink, Quikrete, Non shrink, Quikrete non shrink precision

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of NON-SHRINK GROUTING 03 62 00 - QUIKRETE

1 1. Product NameQUIKRETE NON-SHRINK precision Grout #1585-002. ManufacturerThe QUIKRETE CompaniesOne Securities Centre3490 Piedmont Rd., NE, Suite 1300 Atlanta, GA 30305(404) 634-9100 Fax: (404) Product DescriptionBASIC USET ypical applications for QUIKRETE Non-ShrinkPrecision Grout include GROUTING of: All types of machinery Steel columns Bearing plates Precast concrete Other anchoring conditions that requirehigh in-service strengthThe nonshrink characteristics of Non-ShrinkPrecision Grout make it stable and capable ofhandling high load & MATERIALSQUIKRETE NON-SHRINK precision Grout is a non-metallic Portland cement based precision Grout is a preblendedproduct including expansive additives, requiringonly the addition of water to obtain flowableproperties and high 50 lb ( kg) bagsCOLORS GrayYIELDA 50 lb ( kg) bag of QUIKRETE Non-ShrinkPrecision Grout will yield cu ft ( L) atflowable proper cleaning and wetting of surfaces tobe grouted is vital to maximum and cold temperature precautions, as theyapply to concrete, should also be Technical DataAPPLICABLE STANDARDSASTM International ASTM C109/C109M Standard Test Method forCompressive Strength of Hydraulic CementMortars (Using 2-in.)

2 Or [50-mm] CubeSpecimens) ASTM C827 Standard Test Method forChange in Height at Early Ages of CylindricalSpecimens of Cementitious Mixtures ASTM C939 Standard Test Method for Flow ofGrout for Preplaced-Aggregate Concrete(Flow Cone Method) ASTM C1090 Standard Test Method forMeasuring Changes in Height of CylindricalSpecimens from Hydraulic-Cement Grout ASTM C1107 Standard Specification forPackaged Dry, Hydraulic-Cement Grout(Nonshrink) ASTM E488 Standard Test Methods forStrength of Anchors in Concrete andMasonry Army Corps of Engineers (USACE) - CRD 621 PHYSICAL/CHEMICAL PROPERTIESQUIKRETE NON-SHRINK precision Grout complieswith all properties of ASTM C1107 and CRD 621producing the results shown in Table InstallationMIXINGQUIKRETE NON-SHRINK precision Grout should bemechanically mixed for a minimum of 5 the minimumamount of water necessaryto produce the desired flow characteristics asindicated in Table 2.

3 Do not exceed a flow of20 seconds per ASTM to receive the grout must be cleanNON- shrink GROUTING03 62 00 The QUIKRETE Companies TABLE 1 TYPICAL PHYSICAL PROPERTIES AT 73 F (23 C)Compressive strength, ASTM C109 modified perASTM C1107 Plastic consistency1 day3000 psi ( MPa)3 days9500 psi ( MPa)7 days10,000 psi ( MPa)28 days14,000 psi ( MPa)Height change, ASTM C10901, 3, 7 and 28 days0 - change, ASTM C827+ consistency1 day3000 psi ( MPa)3 days9000 psi ( MPa)7 days9500 psi ( MPa)28 days12,500 psi ( MPa)Height change, ASTM C10901, 3, 7 and 28 days0 - change, ASTM C827+ consistency1 day2500 psi ( MPa)3 days5000 psi ( MPa)7 days6000 psi ( MPa)28 days8000 psi ( MPa)Height change, ASTM C10901, 3, 7 and 28 days0 - change, ASTM C827+ strength,35,000 psi (241 MPa)ASTM E488 111 1/4" (31 mm) bolts embedded 9" (225 mm) deep in 3" (75 mm)hole in 2000 psi ( MPa) 2 APPROXIMATE WATER REQUIRED FOR 50 LB( KG) OF GROUTP lastic1 gal ( L)Flowable1 gal + 1 pt ( L)Fluid1 gal + 3 pt ( L)TABLE 3 WORKING TIMET emperatureWorking time50 F (10 C)25 min73 F (23 C)25 min90 F (32 C)15 minQUIKRETE NON-SHRINK precision Grout #1585-00 SPEC-DATA and MANU-SPEC are registered trademarks of Reed Elsevier Inc.

4 The ten part SPEC-DATA format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. 2007 Reed Construction Data. All Rights free of any type of foreign matter, grease,paint, oil, dust or efflorescence. In some cases itmay be necessary to roughen smooth surfacesor etch old ones with acid. The area should beflushed and soaked with clean water prior togrouting leaving no standing water. Place thegrout quickly and continuously using light rod-ding to eliminate air TIMEWhen properly mixed to a fluid consistencyQUIKRETE NON-SHRINK precision Grout will com-ply with all portions of ASTM C1107 and CRD621 and retain a fluid consistency for the max-imum usable working times stated in Table temperature should be maintained from50 - 90 degrees F (10 - 32 degrees C) to achievespecified results.

5 Use cold water in hot weatheror hot water in cold weather to achieve desired grout temperature. Do not pour grout if tem-perature is expected to go below 32 degrees F (0 degrees C) within a 12 hour damp cure of at least 3 days is necessary tocontrol the nonshrink characteristics andmaintain strength AvailabilityQUIKRETE NON-SHRINK precision Grout is avail-able at leading concrete construction supplyhouses and distributors. Contact QUIKRETEC onstruction Products for the name of thenearest WarrantyThe QUIKRETE Companies warrant this productto be of merchantable quality when used orapplied in accordance with the instructionsherein. The product is not warranted as suit-able for any purpose or use other than thegeneral purpose for which it is under this warranty is limited to thereplacement of its product (as purchased)found to be defective, or at the shippingcompanies option, to refund the purchaseprice.

6 In the event of a claim under this war-ranty, notice must be given to The QUIKRETEC ompanies in writing. This limited warranty isissued and accepted in lieu of all otherexpress warranties and expressly excludes liability for consequential MaintenanceNone Technical ServicesThe QUIKRETE Companies maintain technicalfield representatives throughout the a local distributor for the name andnumber of the nearest representative, or callQUIKRETE Construction Filing Systems Reed First Source Additional product information is availablefrom the GROUTING03 62 00 The QUIKRETE Companies 6943-09 SPEC-DATA and MANU-SPEC are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. 2007 Reed Construction Data. All Rights Reserved.