Transcription of NS75/NS90 Overhead Neutral Supported Cable - …
1 1-877-611-5122 Priority Wire & Cable , Little Rock, AR PWC-C-2019 NS75/NS90 Overhead Neutral Supported Jacketed Cable Size Insulation Thickness Full Size Neutral Reduced Size Neutral Ampacity* 75 C/90 C Rated Strength Cable Diameter Cable Weight Rated Strength Cable Diameter Cable Weight AWG/Kcmil mm kN mm lbs/km kN mm lbs/km amps Duplex 6 298 - - - 80/95 4 434 363 105/125 2 642 530 140/165 1 866 788 160/190 1/0 1054 875 185/220 2/0 1285 1060 210/255 3/0 1575 1292 245/290 4/0 1936 1579 280/335 2455 2015 325/390 3137 2580 375/450 3640 3052 415/500 477 4295 3660 460/560 500 4790 4014 500/605 Triplex 6 477 - - - 80/95 4 677 607 105/125 2 982 871 140/165 1 1351 1273 160/190 1/0 1626 1448 185/220 2/0 1963 1740
2 210/255 3/0 2385 2104 245/290 4/0 2907 2552 280/335 3702 3265 325/390 4750 4196 375/450 5483 4898 415/500 477 6428 5797 460/560 500 7003 6231 500/605 Quadruplex 6 658 - - - 70/85 4 924 854 95/110 2 1327 1215 125/150 1 1843 1764 145/170 1/0 2207 2028 165/200 2/0 2651 2427 190/230 3/0 3208 2925 220/265 4/0 3895 3537 255/305 4971 4530 290/355 6390 5832 335/410 7357 6767 370/455 477 8599 7963 415/510 500 9259 8480 450/555 *The ampacity ratings are based on Table 36A of the Canadian Electrical Code (CSA ) at ambient temperature of 30 C. All values are nominal and subject to correction 1-877-611-5122 Priority Wire & Cable , Little Rock, AR PWC-C-2019 NS75/NS90 Overhead Neutral Supported Jacketed Cable Application: NS75/NS90 jacketed cables are used for service drop applications and as secondary distribution cables.
3 Our cables are dual listed ns75 & ns90 . Conductors: 2, 3, or 4 Aluminum alloy 1350-H19 hard drawn compact round conductors cabled around a Neutral conductor Insulation: Abrasion, heat and moisture resistant cross linked polyethylene (XLP) insulation Neutral : Compact round ASCR Neutral . For sizes and greater, ACSR Neutral conductors shall be in concentric round stranding Jacket: Heat and moisture resistant poly-vinyl chloride (PVC) jacket, which has a temperature range of -40 C to +90 C Standards: NS75/NS90 cables meet or exceed the following standards CSA No. 129 CSA listed ns75 & ns90 Sunlight resistant Color Code: Cable Construction Phase 1 Phase2 Phase 3 Duplex Black PVC with print legend - - Triplex Black PVC with print legend Red PVC - Quadruplex Black PVC with print legend Red PVC Blue PVC 1-877-611-5122 Priority Wire & Cable , Little Rock.
4 AR PWC-C-2019 NS75/NS90 Overhead Neutral Supported Non-Jacketed Cable Size Insulation Thickness Full Size Neutral Reduced Size Neutral Ampacity* 75 C/90 C Rated Strength Cable Diameter Cable Weight Rated Strength Cable Diameter Cable Weight AWG/Kcmil mm kN mm lbs/km kN mm lbs/km amps Duplex 6 242 - - - 80/95 4 369 299 105/125 2 567 456 140/165 1 732 653 160/190 1/0 909 730 185/220 2/0 1128 904 210/255 3/0 1405 1122 245/290 4/0 1751 1394 280/335 2240 1800 325/390 2793 2235 375/450 3273 2684 415/500 477 3901 3266 460/560 500 4391 3614 500/605 Triplex 6 365 - - - 80/95 4 549 478 105/125 2 832 721 140/165 1 1082 1004 160/190 1/0 1335 1158 185/220 2/0 1649 1426 210/255 3/0 2044 1763 245/290 4/0 2536 2181 280/335 3272 2835 325/390 4061 3507 375/450 4747 4162 415/500 477 5640 5009 460/560 500 6203 5431 500/605 Quadruplex 6 490 - - - 70/85 4 731 660 95/110 2 1102 990 125/150 1 1439 1360 145/170 1/0 1770 1592 165/200 2/0 2180 1956 190/230 3/0 2697 2413 220/265 4/0 3338 2980 255/305 4325 3884 290/355 5354 4796 335/410 6251 5661 370/455 477 7415 6778 415/510 500 8057 7279 450/555 *The ampacity ratings are based on Table 36A of the Canadian Electrical Code (CSA ) at ambient temperature of 30 C.
5 All values are nominal and subject to correction 1-877-611-5122 Priority Wire & Cable , Little Rock, AR PWC-C-2019 NS75/NS90 Overhead Neutral Supported Non-Jacketed Cable Application: NS75/NS90 non-jacketed cables are used for service drop applications and as secondary distribution cables. Our cables are dual listed ns75 & ns90 . Conductors: 2, 3, or 4 Aluminum alloy 1350-H19 hard drawn compact round conductors cabled around a Neutral conductor Insulation: Abrasion, heat and moisture resistant cross linked polyethylene (XLP) insulation Neutral : Compact round ASCR Neutral . For sizes and greater, ACSR Neutral conductors shall be in concentric round stranding Standards: NS75/NS90 cables meet or exceed the following standards CSA No. 129 CSA listed ns75 & ns90 Sunlight resistant Phase ID: Cable Construction Phase 1 Phase2 Phase 3 Duplex Black with print legend - - Triplex Black with print legend Black with 3 red stripes - Quadruplex Black with print legend Black with 3 red stripes Black with 3 blue stripes