1-877-611-5122 Priority Wire & Cable, Little Rock, AR PWC-C-2012 Single Conductor Aluminum acwu 600v xlpe insulation PWC part number Gauge Size Bonding Wire Size Min Avg insulation Thickness (mm) Nominal Overall Diameter Aluminum Weight (kg/km) Net Weight (kg/km) insulation mm Armor mm Cable mm acwu -4/001 4/0 2 387 750 acwu -25001 250 1 464 893 acwu -35001 350 1/0 630 1107 acwu -50001 500 2/0 884 1417 acwu -60001 600 2/0 1031 1635 acwu -75001 750 3/0 1262 1942 acwu -10001 1000 3/0 1627 2536 All values are nominal and subject to correction Application: acwu is for exposed and concealed wiring in wet of dry locations and where exposed to the weather.

1-877-611-5122 Priority Wire & Cable, Little Rock, AR PWC-C-2012 Single Conductor Aluminum ACWU 600V XLPE insulation PWC part number Gauge

Tags:

  Single, Aluminum, Insulation, Conductor, Xlpe, 600v, Single conductor aluminum acwu 600v xlpe, Acwu, Single conductor aluminum acwu 600v xlpe insulation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Single Conductor Aluminum ACWU 600V XLPE …

1 1-877-611-5122 Priority Wire & Cable, Little Rock, AR PWC-C-2012 Single Conductor Aluminum acwu 600v xlpe insulation PWC part number Gauge Size Bonding Wire Size Min Avg insulation Thickness (mm) Nominal Overall Diameter Aluminum Weight (kg/km) Net Weight (kg/km) insulation mm Armor mm Cable mm acwu -4/001 4/0 2 387 750 acwu -25001 250 1 464 893 acwu -35001 350 1/0 630 1107 acwu -50001 500 2/0 884 1417 acwu -60001 600 2/0 1031 1635 acwu -75001 750 3/0 1262 1942 acwu -10001 1000 3/0 1627 2536 All values are nominal and subject to correction Application: acwu is for exposed and concealed wiring in wet of dry locations and where exposed to the weather.

2 It is used in ventilated, non-ventilated and ladder type cable trays. acwu is suitable for direct earth burial (with protection as required by inspection authority), as well as for service entrance above or below ground. Minimum recommended installation temperature is -25 C. Maximum Conductor temperature 90 C. Conductors: acwu conductors are a compact soft drawn bare 8000 series Aluminum , with Class B stranding per ASTM insulation : acwu has abrasion, heat and moisture resistant cross-linked polyethylene insulation xlpe (RW90) Armor: acwu has an interlocked Aluminum armor over the cabled conductors Jacket: acwu has abrasion, heat and moisture resistant PVC jacket Standards: acwu meets or exceeds the following standards CSA Spec.

3 , No. 131-M89 Sunlight resistant, FT-4 AG-14