Okoguard URO-J - Okonite

Okoguard URO-J 15kV Underground Primary Distribution Cable-JacketedRed Identification StripesFilled Strand Aluminum Conductor/105 C Rating100% and 133% Insulation LevelsAConductor-Stranded Aluminumwith Filled StrandStrand Screen - ExtrudedBSemiconducting EPRCI nsulation- Okoguard EPRDI nsulation Screen - ExtrudedSemiconducting EPREC oncentric Conductor-BareCopper WiresEncapsulating Jacket-OkoleneFwith Extruded ID Stripes & NESC lightning boltProduct DataSection 2: sheet 36 InsulationOkoguard is Okonite 's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balance ofelectrical and physical properties for long,problem free triple tandem extrusion of the screens withthe insulation provides optimum compressed conductors are filled with awater swellable agent.

WG OKOGUARD EPR 100% INSUL -40°C. ... Section 2: Sheet 36 P/21010236 THE OKONITE COMPANY Ramsey, New Jersey 07446 (1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral, size requirement. - Available from Customer ServiceAuthorized Stock Item

Tags:

  Sheet, Sunil

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Okoguard URO-J - Okonite

1 Okoguard URO-J 15kV Underground Primary Distribution Cable-JacketedRed Identification StripesFilled Strand Aluminum Conductor/105 C Rating100% and 133% Insulation LevelsAConductor-Stranded Aluminumwith Filled StrandStrand Screen - ExtrudedBSemiconducting EPRCI nsulation- Okoguard EPRDI nsulation Screen - ExtrudedSemiconducting EPREC oncentric Conductor-BareCopper WiresEncapsulating Jacket-OkoleneFwith Extruded ID Stripes & NESC lightning boltProduct DataSection 2: sheet 36 InsulationOkoguard is Okonite 's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balance ofelectrical and physical properties for long,problem free triple tandem extrusion of the screens withthe insulation provides optimum compressed conductors are filled with awater swellable agent.

2 This construction slowsthe migration of water through the strands inthe event of a mechanical dig-in followed byexternal exposure to insulation screen of ethylene-propylenerubber is extruded over the insulation. Thecopper concentric wires are uniformly spacedaround the insulation screen. The overallpolyethylene jacket provides protection againstmechanical damage and identification is provided through theuse of three red stripes placed 120 apart in theblack jacket, with an NESC lightning URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be burieddirectly or installed in underground ducts Conductor:Aluminum per ASTMB-609, Class B stranded per Strand:Water swellable agent meets orexceeds ICEA T-31-610 water penetrationresistance and ANSI/NEMA class Aconnectorability Screen:Extruded semiconuctingethylene-propylene rubber meets or exceedsthe requirements of ICEA S-94-649, AEIC CS8,and CSA :Extruded Okoguard meets orexceeds the requirements of ICEA S-94-649,AEIC CS8, and Screen:Extruded semiconductingethylene-propylene rubber meets or exceedsthe requirements of ICEA S-94-649, AEIC CS8,and CSA Conductor:Bare copper.

3 Black Okolene with red extrudedstripes meets or exceeds the requirementsof ICEA S-94-649, AEIC CS8, and for polyethylene Features Triple tandem extruded, all EPR system. Okoguard cables meet or exceed ICEA standards. Meets RUS for cables with filledstrand or solid conductor and 133%insulation level. 105 C continuous operating C emergency rating. 250 C short circuit rating. Excellent corona resistance. Low dielectric constant and power factor. Screens are clean stripping. Exceptional resistance to "treeing". Filled strand conductor. Moisture resistant. Overall jacket provides extended life. Excellent resistance to most chemicals. Can be listed by UL as Type MV-90 onSpecial Orders. CSA listed, LTGG (-40 C), SR. Design Options:Additional conductor sizesCopper central conductorCopper flat strap concentric neutralProduct identification via colored jackets.

4 Improved Temperature insulation system has beentested and qualified for operation at 105 Ccontinuous and 140 C emergency operatingtemperature. Minimum installation temperature of-40 AWG Okoguard EPR 100% INSUL Okonite s web site, contains the most up to date URO-J15kV Underground Primary Distribution Cable-JacketedRed Identification StripesFilled Strand Aluminum Conductor/105 C Rating100% Insulation LevelOkoguard Insulation: 175 mils 100% Insulation LevelProduct DataSection 2: sheet 36 THE Okonite COMPANYR amsey, New Jersey 07446(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral,size requirement.. Available from our Customer ServiceAuthorized stock (2) Full neutral, single phase ampacities are based on ICEAP-117-734 for 90 C or 105 C conductor temperature, 25 Cambient temperature, 100% load factor, and earth thermal resistivityof RHO third neutral ampacities are based on triplexed or triangularconfiguration for the same conditions stated NumberConductor size(AWG or kcmil)Approx.

5 Net Approx. Ship Nominal Dia. over Insulation (in.)Nominal Dia. over InsulationScreen (in.)Copper Neutral, No. xAWG (1)Nominal (in.)90 C Ampacity Direct Burial (2) 90 C Ampacity Duct (2) 105 C Ampacity Direct Burial (2) 105 C Ampacity Duct (2) Insulation ScreenThickness (mils)FULL NEUTRAL 163-23-2060163-23-2066 163-23-2072163-23-20752(7X)1(19X)1/0(19X )2/0(19X) 30 30 30 30 626588 698667 778793 910170 125195 145220 160250 185185 135210 155235 175270 205163-23-2078163-23-2081163-23-2084163- 23-20903/0(19X)4/0(19X)250(37X)350(37X) 30 30 30 40 10291131 12381270 14181603 1793285 210320 240350 270425 310310 230350 260380 295460 3401/3 NEUTRAL162-23-2060162-23-2066162-23-2072 2(7X)1(19X)1/0(19X)

6 30 30 30 579506 617550 662150 120175 140195 155165 135185 150215 170162-23-2075162-23-2078162-23-2081162- 23-20842/0(19X)3/0(19X)4/0(19X)250(37X) 30 30 30 30 726697 889794 922895 1018225 180255 200285 235305 250240 195275 220310 255330 275162-23-2090162-23-2093162-23-2096162- 23-2099350(37X)500(37X)750(61X)1000(61X) 40 40 40 40 13151476 16912066 24022645 3059375 310450 370545 460620 520405 335490 405595 505675 570 Okonite s web site, contains the most up to date URO-J15kV Underground Primary Distribution Cable-JacketedRed Identification StripesFilled Strand Aluminum Conductor/105 C Rating133% Insulation LevelsOkoguard Insulation: 220 mils 133% Insulation LevelProduct DataSection 2: sheet 36Q/22050236 THE Okonite COMPANYR amsey, New Jersey 07446(1) Individual wire size and count may vary.

7 The resulting combination meets the 1/3 or full neutral, size requirement. - Available from Customer ServiceAuthorized Stock (2) Full neutral, single phase ampacities are based on ICEA P-117-734 for 90 C or 105 C conductor temperature, 25 Cambient temperature, 100% load factor, and earth thermalresistivity of RHO third neutral ampacities are based on triplexed ortriangular configuration for the same conditions stated NumberConductor size(AWG or kcmil)Approx. Net Approx. Ship Nominal Dia. over Insulation (in.)Nominal Dia. over InsulationScreen (in.)Copper Neutral, No. xAWG (1)Nominal (in.)90 C Ampacity Direct Burial (2) 90 C Ampacity Duct (2) 105 C Ampacity Direct Burial (2) 105 C Ampacity Duct (2) Insulation ScreenThickness (mils)FULL NEUTRAL 163-23-3060163-23-3066 163-23-3072163-23-30752(7X)1(19X)1/0(19X )2/0(19X) 30 30 30 30 669670 766748 820902 996170 125195 145220 160250 185185 135210 155235 175270 205163-23-3078163-23-3081163-23-3084163- 23-30903/0(19X)4/0(19X)250(37X)350(37X) 30 30 40 40 11251228 13471410 16061721 1912285 210320 240350 270425 310310 230350 260380 295460 3401/3 NEUTRAL162-23-3060162-23-3066162-23-3072 162-23-30752(7X)1(19X)1/0(19X)

8 2/0(19X) 30 30 30 30 627588 684631 733701 810150 120175 140195 155225 180165 135185 150215 170240 195162-23-3078 162-23-3081162-23-3084 162-23-30903/0(19X)4/0(19X)250(37X)350(3 7X) 30 30 40 40 905887 10051029 11641246 1425255 200285 235305 250375 310275 220310 255330 275405 335 162-23-3093 162-23-3096 162-23-3099500(37X)750(61X)1000(61X) 40 40 55 18532209 24682807 3093450 370545 460620 520490 405595 505675 570