Example: marketing

Operating manual - BENDER

Operating manualUNIMET 800 STTesting system forelectrical safetyTGH1381 W. BENDER GmbH & Str. 65 35305 Gr nberg Box 1161 35301 Gr nberg GermanyTel.: +49 (0)6401-807-0 Fax: +49 (0)6401-807-259E-Mail: W. BENDER GmbH & rights only with permissionof the to change!Bentron GmbH & 8 35305 Gr nberg Box 1161 35301 Gr nberg GermanyTel.: +49 (0)6401-807-730 Fax: +49 (0)6401-807-739E-Mail: : Distribution:3 Table of ContentsTGH1381 How to use this Operating manual effectively .. this Operating manual .. Support .. of symbols .. of chapters .. 82. Safety instructions .. use .. personnel .. safety notes .. and liability .. statement .. 103. System description .. of application .. conforming to standards .. components .. elements .. 144. Operating and setting .. touch screen .. the printer .. an external keyboard .. device settings .. principle.

TGH1381en/01.2006 7 1. How to use this operating manual effectively 1.1 About this operating manual This operating manual describes the UNIMET® 800ST with the software version 2.2.

Tags:

  Manual, Operating, Operating manual, Benders

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Operating manual - BENDER

1 Operating manualUNIMET 800 STTesting system forelectrical safetyTGH1381 W. BENDER GmbH & Str. 65 35305 Gr nberg Box 1161 35301 Gr nberg GermanyTel.: +49 (0)6401-807-0 Fax: +49 (0)6401-807-259E-Mail: W. BENDER GmbH & rights only with permissionof the to change!Bentron GmbH & 8 35305 Gr nberg Box 1161 35301 Gr nberg GermanyTel.: +49 (0)6401-807-730 Fax: +49 (0)6401-807-739E-Mail: : Distribution:3 Table of ContentsTGH1381 How to use this Operating manual effectively .. this Operating manual .. Support .. of symbols .. of chapters .. 82. Safety instructions .. use .. personnel .. safety notes .. and liability .. statement .. 103. System description .. of application .. conforming to standards .. components .. elements .. 144. Operating and setting .. touch screen .. the printer .. an external keyboard .. device settings .. principle.

2 Bar .. "Action" menu .. "View" menu .. "?" icon .. window .. 19 Table of Contents4 TGH1381 to use the context menu when only one entry is activated .. to use the context menu when several entries are activated .. to use the selection filter .. bar .. software keyboard .. folder .. engineer names .. is how you access the "Test engineers" catalogue .. is how you select the name of a test engineer (log in) .. in, edit or delete test engineer .. is how you enter a new test engineer name .. settings .. system control .. settings .. / Time .. settings .. panel .. and sounds .. CE system .. of the active test probe/measuring cable .. voltage .. (USB) .. RS-232 .. Update .. 335. Testing and measuring .. concept .. method .. part .. type .. sequence .. 39 Table of Contents5 TGH1381 inspection .. classification .. test .. the DUT.

3 Visual inspection .. electrical tests .. conductor test .. function test .. the test result .. "Test specifications" folder .. is how to get to the "Test specifications" folder .. is how you start a test from the "Test specifications" folder .. "Test specifications" folder: start test and edit test specification .. "Device protocols" folder .. is how you enter the "Device protocols" folder .. is how you start a test from the "Device protocols" folder .. "Device protocols" folder: Start test and edit protocol .. measurement .. is how you access "Single measurements" .. is how you start a "Single measurement" .. 546. Functions of the UNIMET 800ST that can be used via a PC .. requirements, functions, preparations .. is how you prepare the UNIMET 800ST for communication with a PC .. of remote control .. the remote control function .. from the command list of the UNIMET 800ST.

4 : Remote control of the PE conductor resistance measurement .. update .. 1: Transferring the update files .. 2: Updating the Operating software .. text for print-out, test data import , data management .. of logo and header text .. data import .. to export, print or delete test specifications .. to export, print or delete device protocols .. to save a backup of the test database .. 667. Maintenance and calibration .. 67 Table of Contents6 TGH1381 the battery .. faults .. 678. Data .. standards .. standards .. used .. steps .. data .. information .. 747 TGH1381 How to use this Operating manual About this Operating manualThis Operating manual describes the UNIMET 800ST with the software version Other versions may have deviating functions or involve different Operating steps. This manual is intended for experts in the areas of electronics and electrical using the equipment, please take the time to read this Operating manual carefully.

5 Keep these documents to hand in the vicinity of the manual has been compiled with great care. Nevertheless, errors cannot be entirely ex-cluded. The BENDER companies do not accept any liability for injuries to persons or dam-ages to equipment due to errors in this registered trademarks used in this manual are trademarks of their respective owners. Technical SupportAs a customer, you will receive technical support and answers to any questions you may have relating to the devices you have purchased. In the event of a query, please contact Technical Sales at BENTRON .BENTRON GmbH & Box 11 61 35301 Gr nberg GermanyCarl-Benz-Stra e 8 35305 Gr nberg GermanyTel: +49 (0) 64 01-807 731 Fax: +49 (0) 64 01-807 739E-mail: Explanation of symbols The following designations and symbols are used in BENDER documentation for hazards and warnings:This symbol indicates an immediate danger to life and health of persons.

6 Failureto observe these instructions means that death, serious injury or considerabledamage to property shall occur if the corresponding precautions are not taken. How to use this Operating manual effectively8 TGH1381 Overview of chaptersChapter 1:How to use this Operating manual provides tips and useful information on how to use this 2:Safety describes the dangers during installation and when Operating the 3:Description of informs about the system's properties, functions and 4: Operating and informs about commissioning, Operating principles and 5:Testing and describes the classification, testing and test 6:Functions of the UNIMET 800ST that can be used via a explains remote control and how updates are carried 7:Maintenance and explains the steps that should be taken during calibration or in the event of a malfunction. Chapter 8 provides information on standards, the testing procedure and technical symbol indicates a potential danger to life and health of persons.

7 Failure to observe these instructions means that death, serious bodily injury orconsiderable damage to property may occur if the corresponding precautionsare not symbol indicates a potentially dangerous situation. Failure to observe theseinstructions means that minor bodily injury or damage to property can occur ifthe respective precautions are not symbol provides important information about the proper use of to observe these instructions can lead to malfunctions in the equipmentor in its symbol gives tips on operation and useful information, which may assistyou to make optimal use of all of the equipment's functions. 9 TGH1381 Safety DeliveryCheck that the packaging is undamaged and compare the contents with the delivery papers. Never commission a damaged device. BENTRON must immediately be notified of any dam-age in may only be stored in rooms in which they are protected against dust, dampness, splashes and dripping water and in which the specified storage temperatures are distributor's "General Terms of Sale and Delivery" apply in all cases.

8 Intended useThe testing systems UNIMET 800ST are to be used exclusively for the applications de-scribed in the Chapter "3. System description".Intended use also embraces the observance of all notes and instructions in this Operating manual and adherence to the defined test other form of utilization does not fall under intended use. The BENDER companies shall not be held liable for damages resulting from inappropriate Skilled personnelThe BENDER devices must be operated by appropriately trained and qualified persons. Here,qualified means that the person is familiar with the assembly, commissioning and operation of the device and has received appropriate training in this area. The personnel must have read this Operating manual and fully understood all the safety notes prior to working on the device. BENTRON would be happy to demonstrate how the device is General safety notesBENDER devices are built using state-of-the-art technology and under observance of all the applicable safety regulations.

9 Nevertheless, the utilization of the devices can endanger the life and health of the user or other persons or cause damage to the BENDER devices or other property. Only use BENDER devices: within the scope of their intended use when they are in perfect condition and all safety requirements have been fully complied with in accordance with the rules and regulations on accident prevention that are applicable for the place of utilization. Eliminate all faults which may have an adverse effect on instructions10 TGH1381 Never make any unpermitted modifications and only use spare parts and add-on units that have been purchased from or recommended by the manufacturer of the devices. Failure to do this may result in fires, electrical shocks and injury. Information labels must be clearly legible at all times. Damaged or illegible information labels must be replaced Warranty and liabilityWarranty and liability claims for personal injuries and damage to property are excluded if they are attributable to one or more of the following causes: Use of the UNIMET 800ST other than for the intended purpose.

10 Inappropriate installation, commissioning, operation and maintenance. Operation of equipment with defective safety devices or which are not correctly positioned or are not capable of functioning. Failure to observe the instructions in this Operating manual and the supplement "Important Safety Notes for BENDER Products" with regard to transportation, storage, and installation. Unauthorized structural modifications. Failure to observe the technical data. Inappropriate repairs and the use of spare parts or accessories which do not have manufac-turer's approval. Cases of disaster, uncontrollable external factors and force Warranty statementThe BENTRON testing system UNIMET 800ST comes with a 36-month guarantee for error-free design and perfect material quality under normal storage and Operating conditions. The guarantee period commences from the date of guarantee does not cover maintenance work of any kind. The guarantee applies for the original purchaser and does not extend to products or indivi-dual components that were not used in an appropriate manner or on which modifications were carried out.