Transcription of OPERATOR’S MANUAL - taylor-company.com
1 OPERATOR SMANUALM odel 150, 152, 162, & 168 Soft Serve FreezersOriginal Operating Instructions028749-M8/13/08 (Original Publication)Updated 8/3/15 Complete this page for quick reference when service is required:Taylor Distributor:Address:Phone:Service:Parts: Date of Installation:Information found on data plate:Model Number:Serial Number:Electrical Specs: VoltageCyclePhaseMaximum Fuse Size:AmpsMinimum Wire Ampacity:AmpsPart Number:E2008 Carrier Commercial Refrigeration, MAny unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work may bea violation of Copyright Law of the United States of America and other countries, could result in the awarding of StatutoryDamages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal rights Companya division of Carrier Commercial Refrigeration, N.
2 Blackhawk , IL 61072 Table of ContentsModels 150, 152, 162, 168 Table of ContentsSection 1To the Cooled Hook- Up Installation For60 Cycle, 1 Phase, Supplied With Cord and Connections ForModels Without Cord and Plug 2To the 4 Operator Parts 150 & 152 Door 162 & 168 Door 150 and 152 162 and 168 5 Important: To the Quality Light - Mix Low Refrigeration Hopper Refrigeration (SHR) Temperature Retention (CTR) 6 Operating 150, 152, 162, 168 Table of ContentsTable of Contents - Page 2 Closing Product From the Freezing 7 Important: Operator Cleaning and Bacterial Maintenance 8 Troubleshooting 9 Parts Replacement 10 Limited Warranty on 11 Limited Warranty on : Continuing research results in steady improvements; therefore, informationin this MANUAL is subject to change without : Only instructions originating from the factory or its authorized translationrepresentative(s) are considered to be the original set of Carrier Commercial Refrigeration, Inc.
3 (Original Publication)Updated August, 2015028749- MAny unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this workmay be a violation of Copyright Law of the United States of America and other countries, could result in theawarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in furthercivil and criminal rights Companya division of Carrier Commercial Refrigeration, N. Blackhawk , IL 610721 Models 150, 152, 162, 168To the Installer131122 Section 1To the InstallerThe following information has been included in themanual as safety and regulatory guidelines. Forcomplete installation instructions, please see theInstallation SafetyIn all areas of the world, equipment should beinstalled in accordance with existing local contact your local authorities if you have should be taken to ensure that all basic safetypractices are followed during the installation andservicing activities related to the installation andservice of Taylor authorized Taylor service personnelshould perform installation and repairs on service personnel should consultOSHA Standard or theapplicable code of the local area for theindustry standards on lockout/tagoutprocedures before beginning any installationor service personnel must ensurethat the proper PPE is available and wornwhen required during installation and service personnel must remove allmetal jewelry, rings, and watches beforeworking on electrical main power supply(s)
4 To the freezer mustbe disconnected prior to performing any to follow this instruction may result in personalinjury or death from electrical shock or hazardousmoving parts as well as poor performance or damageto the :Allrepairsmustbeperformedbyanauthorized Taylor Service unit has many sharp edges that cancause severe PreparationReview the area the unit is to be installed in beforeuncrating the unit, making sure that all possiblehazards the user or equipment may come into havebeen Indoor Use Only:This unit is designed tooperateindoors, under normal ambient temperatures of70_-75_F(21_-24_C). The unit has successfullyperformed in high ambient temperatures of104_(40_C) at reduced unit mustNOTbe installed in an areawhere a water jet or hose can be awater jet or hose to rinse or clean the unit.
5 Failure tofollow this instruction may result in unit must be installed on a level surfaceto avoid the hazard of tipping. Extreme care should betaken in moving this equipment for any reason. Two ormore persons are required to safely move this to comply may result in personal injury orequipment the unit and inspect it for damage. Report anydamage to your Taylor piece of equipment is made in the USA and hasUSA sizes of hardware. All metric conversions areapproximate and vary in 150, 152, 162, 168To the Installer101122 Air Cooled UnitsThe models 150 and 152 require a minimum of 6 (152mm) of clearance around both sides. Install the skirtprovidedontheright sideof theunit andplace thebackof the unit against a wall to prevent recirculation ofwarm air. The model 162 requires 6 (152 mm) on allsides and the skirt installed on the rear of the unit.
6 Themodel 168 requires 3 (76 mm) on all sides and theskirt installed on the rear of the unit. Minimum airclearances must bemet toassure adequateair flow foroptimum units are designed for indoor use NOTinstall the units in an area where awater jet could be used. Failure to follow thisinstruction may result in serious electrical Hook- Up Installation For60 Cycle, 1 Phase, Supplied With Cord and PlugThis equipment is supplied with a 3- wire cord andgrounding type plug for connection to a single phase,60 cycle, branch circuit supply. This unit must beplugged into a properly grounded receptacle. The cordand plug provided for 115/60/1, is 20 amp; thereforethe wall outlet must also be 20 amp. Check the datalabel, located on the side panel, for wiringmay beemployedif requiredby localcodes.
7 Instructions for conversionto permanent wiringare as follows:1. Be sure the freezer is electrically Remove the appropriate panel and locate thesmall electrical box at the base of the Remove the factory- installed cord and strainrelief Route incoming permanent wiring through 7/8 (22 mm) hole in base Connect two power supply leads. Attach ground(earth) wire to the grounding lug inside theelectrical Be sure the unit is properly grounded beforeapplying YOUR LOCAL ELECTRICAL CODES!Electrical Connections ForModels Without Cord and Plug SuppliedEach freezer requires one power supply for each datalabel. Check thedatalabel(s) onthe freezer for branchcircuit overcurrent protection or fuse, circuit ampacity,and electrical specifications. Refer to the wiringdiagram provided inside of the control box, for properpower the United States, this equipment is intended to beinstalled in accordance with the National ElectricalCode (NEC), ANSI/NFPA 70- 1987.
8 The purpose ofthe NEC code is the practical safeguarding of personsand property from hazards arising from the use ofelectricity. This code contains provisions considerednecessary for safety. Compliance therewith andproper maintenance will result in an installationessentially free from hazard! In all other areas of theworld, equipment should be installed in accordancewith the existing local codes. Please contact your : THIS EQUIPMENT MUST BEPROPERLY GROUNDED! FAILURE TO DO SOCAN RESULT IN SEVERE PERSONAL INJURYFROM ELECTRICAL SHOCK!This unit is provided with an equipotentialgrounding lug that is to be properly attachedto therearof theframeby the authorizedinstaller. Theinstallationlocation is marked by the equipotential bondingsymbol (5021 of IEC 60417-1) on both the removablepanel and the equipment s 150, 152, 162, 168To the Installer130809 SStationary appliances which are not equippedwitha power cord anda plugor another deviceto disconnect the appliance from the powersource must have an all-pole disconnectingdevice with a contact gap of at least 3 mminstalled in the external that arepermanently connectedtofixed wiring and for which leakage currentsmay exceed 10 mA, particularly whendisconnected, not used for long periods, orduring initial installation, shall have protectivedevices such as a GFI to protect against theleakage of current, installed by authorizedpersonnel to the local cords used with this unit shall beoil-resistant, sheathed flexible cable.
9 Notlighter than ordinary polychloroprene or otherequivalent synthetic elastomer-sheathedcord(Code designation 60245 IEC 57) installedwith the proper cord anchorage to relieveconductors from strain, including twisting, atthe terminals and protect the insulation of theconductors from the supply cord is damaged, it must bereplaced by the manufacturer, its serviceagent, or similarly qualified person, in order toavoid a RotationBeater rotation must be clockwise as viewedlooking into the freezing : The following procedures should beperformed by an authorized service correct rotation on a three- phase unit, interchangeany two incoming power supply lines at freezer mainterminal block only. To correct rotation on asingle- phase unit, change the leads inside the beatermotor.
10 (Follow diagram printed on motor.)Electrical connections are made directly to theterminal block provided in the splice box, mounted onthe base pan on each side of the model 168, andlocated in the splice boxes mounted mid- level on theframe channel on the sides of the model consideration of our environment, Tayloruses only earth friendly HFC refrigerants. The HFCrefrigerant used in this unit is R404A. This refrigerantis generally considered non-toxic and non-flammable,with an Ozone Depleting Potential (ODP) of zero (0).However, any gas under pressure is potentiallyhazardous and must be handled with fill any refrigerant cylinder completely withliquid. Filling the cylinder to approximately 80% willallow for normal only R404A refrigerant that conforms tothe AHRI standard 700 specification.