Example: dental hygienist

Orient Electronics CSF SERIES(TRIPLE OUTPUT)

Orient ElectronicsCSF SERIES ( triple OUTPUT) Orient ELECTRONICS74 CSF15-TRIPLESPECIFICATIONSMODELCSF15-DDC SF15-EEINPUTVOLTAGE, FREQUENCYAC100-240V (AC 85 ~ 264V or DC120 ~ 370V), 50/60Hz (47 ~ 440Hz or DC), Universal input voltageCURRENT[A] (I =100%) (I =100%)EFFICIENCY[%]110V69 typ68 typ220V67 typ67 typINRUSH CURRENT20A typ (AC IN 110V, I =100%), 40A typ (AC IN 220V, I =100%) at cold [V]5121251515 CURRENT[A] ~ ~ , LINE[mV]25 Max120 Max120 Max25 Max150 Max150 MaxREGULATION, LOAD[mV]50 Max120 Max120 Max50 Max150 Max150 MaxRIPPLE[mVp-p]80 Max120 Max120 Max80 Max120 Max120 MaxRIPPLE, NOISE[mVp-p]120 Max150 Max150 Max120 Max150 Max150 MaxTEMPERATURE DRIFT 0~+50 C[mV]75 Max180 Max180 Max75 Max225 Max225 MaxRISE TIME[ms]800 Max (AC IN 110V I =100%)HOLDING TIME[ms]16 typ (AC IN 110V I =100%)PROTECTION CIRCUITOVER CURRENT PROTECTIONW orks at over 110% of rating and recovers automaticallyOVER VOLTAGE PROTECTIONW orks at 115 ~ 140% of rating (except for CH2, CH3)ELECTRICALLYISOLATEDINPUT-OUTPUTAC 3,000V 1 minute current 20mA, DC 500V 100M (At room temperature & Humidity)INPUT-FGAC 2,000V 1 minute current 20mA, DC 500V 100M (At room temperature & Humidity) output -FGAC 500V 1 minute current 100mA, DC 500V 100M (At room temperature & Humidity)ENVIRONMENTOPERATING TEMP AND HUMID-10 ~ +70 C(Required Derating), 20 ~ 90% RH ()

Orient Electronics CSF SERIES(TRIPLE OUTPUT) 74 ORIENT ELECTRONICS CSF15-TRIPLE SPECIFICATIONS MODEL CSF15-DD CSF15-EE INPUT VOLTAGE, FREQUENCY AC100-240V (AC 85 ~ 264V or DC120 ~ 370V), 50/60Hz (47 ~ 440Hz or DC), Universal input voltage

Tags:

  Output, Triple, Triple output

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Orient Electronics CSF SERIES(TRIPLE OUTPUT)

1 Orient ElectronicsCSF SERIES ( triple OUTPUT) Orient ELECTRONICS74 CSF15-TRIPLESPECIFICATIONSMODELCSF15-DDC SF15-EEINPUTVOLTAGE, FREQUENCYAC100-240V (AC 85 ~ 264V or DC120 ~ 370V), 50/60Hz (47 ~ 440Hz or DC), Universal input voltageCURRENT[A] (I =100%) (I =100%)EFFICIENCY[%]110V69 typ68 typ220V67 typ67 typINRUSH CURRENT20A typ (AC IN 110V, I =100%), 40A typ (AC IN 220V, I =100%) at cold [V]5121251515 CURRENT[A] ~ ~ , LINE[mV]25 Max120 Max120 Max25 Max150 Max150 MaxREGULATION, LOAD[mV]50 Max120 Max120 Max50 Max150 Max150 MaxRIPPLE[mVp-p]80 Max120 Max120 Max80 Max120 Max120 MaxRIPPLE, NOISE[mVp-p]120 Max150 Max150 Max120 Max150 Max150 MaxTEMPERATURE DRIFT 0~+50 C[mV]75 Max180 Max180 Max75 Max225 Max225 MaxRISE TIME[ms]800 Max (AC IN 110V I =100%)HOLDING TIME[ms]16 typ (AC IN 110V I =100%)PROTECTION CIRCUITOVER CURRENT PROTECTIONW orks at over 110% of rating and recovers automaticallyOVER VOLTAGE PROTECTIONW orks at 115 ~ 140% of rating (except for CH2, CH3)ELECTRICALLYISOLATEDINPUT-OUTPUTAC 3,000V 1 minute current 20mA, DC 500V 100M (At room temperature & Humidity)INPUT-FGAC 2,000V 1 minute current 20mA, DC 500V 100M (At room temperature & Humidity) output -FGAC 500V 1 minute current 100mA, DC 500V 100M (At room temperature & Humidity)ENVIRONMENTOPERATING TEMP AND HUMID-10 ~ +70 C(Required Derating), 20 ~ 90% RH (Non Condensing)STORAGE TEMP AND HUMID-20 ~ +75 C, 20 ~ 90% RH (Non condensing)

2 VIBRATION10 ~ 55Hz at 1G, 3 minutes period, 30 minutes along X, Y and Z axisIMPACT10G for 20ms, once on each X, Y and Z axisSAFETYEMISSIONPFHCSAFETY REGULATIONCE, CBCE, CBLINE CONDUCTED RF VOLTAGEC omplied with EN55022-A, VL60950-1, EN60950-1 CSF15-DD Inrush current limit Short circuit protection Over voltage protection CH1 isolated from CH2, 3 Over current protection 4 years warrantyOutput voltage combinationTotal output wattageSeries nameORDERING INFORMATION