Example: stock market

Panel Mount output DC Solid State Relay SSC Series

SSC Series Ratings up to 25 A @ 1000 VDC IGBT output CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriersFor Generation 3 datasheet click here DC control Epoxy Free DesignPRODUCT SELECTIONC ontrol Voltage25 A8-16 VDC SSC1000-25-1220-28 VDC SSC1000-25-24 AVAILABLE OPTIONSS eriesRated Load Current25: 25 AmpsControl Voltage12: 8-16 VDC24: 20-28 VDCO perating Voltage1000: 1-1000 VDCSSC10002425 TerminationBlank: Screws & clampK: Installed standoffs with screws for PC Board mounting (1)KNot all part number combinations are Crydom Technical Support for information on the availability of a specific part number.*Required for valid part numberFor options only and not required for valid part numberOUTPUT SPECIFICATIONS(2)Description1000 VDCR ecommended Operating Voltage [Vdc]1-1000 Absolute Maximum Rating [Vdc]1200 Maximum Off- State Leakage Current @ Rated Voltage [mA] Load Current [Adc] (3)25 Minimum Load Current [mA] (4) 20 Maximum Surge Current (10 msec)[Adc]

SSC Series • Ratings up to 25 A @ 1000 VDC • IGBT output • CE Compliant to EN60950-1 • Improved SEMS screw and washer • Redesigned housing with anti-rotation barriers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Panel Mount output DC Solid State Relay SSC Series

1 SSC Series Ratings up to 25 A @ 1000 VDC IGBT output CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriersFor Generation 3 datasheet click here DC control Epoxy Free DesignPRODUCT SELECTIONC ontrol Voltage25 A8-16 VDC SSC1000-25-1220-28 VDC SSC1000-25-24 AVAILABLE OPTIONSS eriesRated Load Current25: 25 AmpsControl Voltage12: 8-16 VDC24: 20-28 VDCO perating Voltage1000: 1-1000 VDCSSC10002425 TerminationBlank: Screws & clampK: Installed standoffs with screws for PC Board mounting (1)KNot all part number combinations are Crydom Technical Support for information on the availability of a specific part number.*Required for valid part numberFor options only and not required for valid part numberOUTPUT SPECIFICATIONS(2)Description1000 VDCR ecommended Operating Voltage [Vdc]1-1000 Absolute Maximum Rating [Vdc]1200 Maximum Off- State Leakage Current @ Rated Voltage [mA] Load Current [Adc] (3)25 Minimum Load Current [mA] (4) 20 Maximum Surge Current (10 msec)[Adc]75 Maximum On- State Voltage Drop @ Rated Current [Vdc] Resistance Junction to Case (Rjc) [ C/W] Heat Sink for Rated Current @ 40 [ C/W]1 Maximum Pulse Width Modulation Frequency [Hz] (5)500 INPUT SPECIFICATIONS(2)

2 DescriptionSuffix -12 Control Voltage Range8-16 VDCM aximum Reverse Voltage-16 VDCN ominal Control Voltage12 VDCM inimum Turn-On Voltage 8 VDCMust Turn-Off Voltage 1 VDCM inimum Input Current (for on- State ) mA Maximum Input Current 15 mANominal Input Impedance [Ohms]Current RegulatedMaximum Turn-On Time [ sec]200 Maximum Turn-Off Time [ sec] 150150 Suffix -2424 VDC20-28 VDC-28 VDC20 VDC1 VDC mA15 mACurrent Regulated200Do not forget to visit us at: 2020 Crydom Inc. Specifications subject to change without MountFDE-07-01 REV. AGENERAL SPECIFICATIONS(2)ParametersDescriptionDi electric Strength, Input/ output /Base (50/60Hz)3750 VrmsMinimum Insulation Resistance (@ 500 VDC)109 OhmMaximum Capacitance, Input/Output8 pFAmbient Operating Temperature Range (6)-40 to 100 CAmbient Storage Temperature Range-40 to 125 CWeight (typical) oz ( g)Housing MaterialUL94 V-0 Baseplate MaterialAluminumInput Terminal Screw Torque Range (in-lb/Nm)13-15 Load Terminal Screw Torque Range (in-lb/Nm)18-20 / Terminal Screw Torque Range (in-lb/Nm) (1)w/ K option 8-10 / Mounting Screw Torque Range (in-lb/Nm)18-20 / per IEC60068-2-7893% non-condensingMTBF (Mean Time Between Failures) at 40 C ambient temperature (7)

3 21,395,130 hours (2,441 years)MTBF (Mean Time Between Failures) at 60 C ambient temperature (7)11,545,504 hours (1,317 years)Recommended Wire SizesTerminalsWire Size( Solid / Stranded)Wire Pull-OutStrength (lb)[N]InputOutput24 AWG ( mm2) / [minimum]2 x 12 AWG ( mm2) / [maximum]20 AWG ( mm2) / [minimum]2 x 10 AWG ( mm2) / x 8 AWG ( mm2) / [maximum]10 [ ]90 [400]30 [133]110 [490]90 [400]WIRING DIAGRAM14+2+3S OLID S T A T E R ELAYOUTPUTINPUTLoad+-V+-V+14+2+3S OLID S T A T E R ELAYOUTPUTINPUT-+V+-VLoad+* Inductive loads must be diode suppresed.** EQUIVALENT CIRCUIT BLOCK DIAGRAMS-DC+DC-DCTriggerCircuitControlCi rcuit+DC4312Do not forget to visit us at: 2020 Crydom Inc.

4 Specifications subject to change without MountInput/ output Terminal Screw Thread Size#6-32 UNC / #8-32 UNCMECHANICAL SPECIFICATIONS(2)(1)Tolerances: in / mmAll dimensions are in: inches [millimeters]Screw Termination1 output +2S OLID S T A T E R ELAY4 INPUT+ [ ] [ ]Mounting Hole/Slot [ ] [ ] [ ] [ ] [ ] [ ] [ ]Hex Standoff Termination ( K Option)1 output +2S OLID S T A T E R ELAY4 INPUT+ [ ] [ ]Mounting Hole/Slot [ ] [ ] [ ] [ ] [ ] [ ] [ ](4 places) [ ] [ ](2 places)(2 places)(1) All parameters at Tc=25 C unless otherwise specified. (2) Heat sinking required, see derating curves. (3) Low current loads and high ambient temperature can affect turn-on time.(4) 8 VDC minimum control voltage.

5 Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current.(5) Decrease maximum control voltage V/ C above 80 C ambient temperature.(6) Option K is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between and inches ( to mm).(7) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). For additional information or specific questions, contact Crydom Technical Current (Amp)Surge Duration (msec) SSC1000 SURGE CURRENT INFORMATIONDuty Factor 10%Duty Factor 20%Duty Factor 50%PeriodPulseWidthFor Pulse Width Modulation applications select the curve according duty factor and pulse duration as following.

6 (i) for Single Surge Pulse Tc=40 C ;Tj 175 C(ii) for Repetitive Surge Pulse Tc=40 C ;Tj 130 C Duty Factor =Pulse Width Periodx100 (%)THERMAL DERATE INFORMATIONS ingle Pulse (i)Duty Factor (10%) (ii)Duty Factor (20%) (ii)Duty Factor (50%) (ii)05101520252030405060708090100 SSC1000 Load Current (Amps)Ambient Temperature ( C) C/W2 C/W5 C/WGENERAL NOTES Do not forget to visit us at: 2020 Crydom Inc. Specifications subject to change without MountAGENCY APPROVALSEN60950-1: Meets the requirements of : 1,7: : : : : :IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 Vibration Resistance: IEC 60068-2-6 : Amplitude Range 10-55 Hz, Displacement Resistance: IEC 60068-2-27 : Peak Acceleration 15g, Duration11msecSSC Series has Environmental Product declarations type III conforming to ISO 14025.

7 Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking CoverHardware KitPart number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output . Used to Mount TMR1 lug Accessories!Protective Cover & Hardware KitsRecommended AccessoriesCoverHardwareKitHeat SinkPart Resistance[ C/W]Lug TerminalThermal PadKS101HK1HK4HS501 DRHS301 / HS301 DRHS251HS201 / HS201 DRHS202 / HS202 DRHS172HS151 / HS151 DRHS122 / HS122 DRHS103 / Do not forget to visit us at: 2020 Crydom Inc. Specifications subject to change without MountRev. 100520 ECN#20981Do not forget to visit us at: 2020 Crydom Inc.

8 Specifications subject to change without MountDANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSIO N, OR ARC FLASH. Di sconnect all power b efore insta lling or working with th is equipment. Verify all connecti ons and r eplace a ll covers b efore tu rning o n t o f ollow these in structio ns will result in d eath or s erio us inju ry. RIESGO DE DESCARGA ELECTRICA O EXPLOSIO N. Desconecta r to dos los suministr os d e energia a e ste equipo antes de tr abajar con e ste equipo. Verificar todas las conexiones y colocar todas las tapas antes de energizer el in cumplimie nto de e stas in struccio nes puede p rovocar la muerte o le sio nes s eria DE DESCHARGE ELECTRIQUE OU EXPLOSION Ete indre to ute s les sources d' nergie de cet a ppareil avant de tr availler dessus d e c et appareil V rifier tousconnections, etremettre tous couverts enolace avant demettre sousDe n on-suiv i de ces instructio ns provoquera la mort o u d es l sio ns s rieuses s EIN ES ELEKTRISCHEN SCHLAGES ODER EINER EXPLOSIO N.

9 Ste llen Sie jeglichen Str om a b, d er dieses G er t versorgt, bevor S ie an dem Ger t Arbeiten durchf hren Vor d em Dr ehen auf Energie alle Anschl sse berpr fen und alle Abdeckungen ssung die ser Anweisungen k nnen z um Tode o der z u schwerenVerle tzungen f DI SCOSSA ELETTRICA O DELL E SPLOSIONE. Spenga tu tt a l'alimenta zioneche f ornisce questa apparecchiaturaprima d i lavorarea questa apparecchiatura Verificare t utti i c ollegamenti e s osti tu ire tu tte le coperture prima dell accensioneL'omis sio ne d i queste istruzioni provocher l a morte ole sio ni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE The product's side panels may be hot, allow the product to cool before touching.

10 Follow proper mounting instructions including torque values. Do not allow liquids or foreign objects to enter this to follow these instructions can result in serious injury, or equipment DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER Les panneaux lat raux du produit peuvent tre chauds. Laisser le produit refroidir avant de le toucher. Respecter les consignes de montage, et notamment les couples de serrage. Ne pas laisser p n trer de liquide ni de corps trangers l'int rieur du non-respect de cette directive peut entra ner,des l sions corporelles graves ou des dommages mat Nichtbeachtung dieser Anweisung kannK rperverletzung oder Materialsch den zur Folge VON MATERIALSCH DEN UND GEH USEERHITZUNG Die Seitenw nde k nnen hei sein.


Related search queries