Passport 12M/17M Bedside Monitor Default Settings

Passport 12M/17M Bedside Monitor Default Settings Hospital, City, ST_____Department_____. Clinical/Sales/Service Representatives_____. Date_____ Software Version_____Signature, Title_____. Maintenance System time Date format: Time format: 12 24. Manage Config (See Configurations). Department: Select Default : User config: General Load latest Load specific User config: User config: User Maintenance Facility Room Change Pt Loc Monitor name Visit #. Dept Bed On Off Language: English On Off Units Ht In Cm CVP mmHg kPa cm/H2O. Wt Lbs Kg CO2 mmHg kPa %. ST mm mV O2 mmHg kPa %. Pressure mmHg kPa Temp F C. Hb Unit g/dl mmol/L g/L tcpCO2/tcpO2 mmHg kPa Network Setup Select CMS Off On Central station setup: Network encryption On Off Alarm setup Min Alarm Vol ECG Lead off level Low Med High Alarm Pause SpO2 sensor off level Low Med High Alarm Sounds ISO Mode1 Mode2 IBP sensor off level Low Med High High Interval Lethal Arr off Disable Enable Med Interval Extended arrh Disable Enable Low Interva

Passport 12M/17M Bedside Monitor Default Settings P/N: 002-08-8026 Rev B *Optional Page 2 of 12 Alarm Setup—See Configurations Review Graphic Trends

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Passport 12M/17M Bedside Monitor Default Settings

1 Passport 12M/17M Bedside Monitor Default Settings Hospital, City, ST_____Department_____. Clinical/Sales/Service Representatives_____. Date_____ Software Version_____Signature, Title_____. Maintenance System time Date format: Time format: 12 24. Manage Config (See Configurations). Department: Select Default : User config: General Load latest Load specific User config: User config: User Maintenance Facility Room Change Pt Loc Monitor name Visit #. Dept Bed On Off Language: English On Off Units Ht In Cm CVP mmHg kPa cm/H2O. Wt Lbs Kg CO2 mmHg kPa %. ST mm mV O2 mmHg kPa %. Pressure mmHg kPa Temp F C. Hb Unit g/dl mmol/L g/L tcpCO2/tcpO2 mmHg kPa Network Setup Select CMS Off On Central station setup: Network encryption On Off Alarm setup Min Alarm Vol ECG Lead off level Low Med High Alarm Pause SpO2 sensor off level Low Med High Alarm Sounds ISO Mode1 Mode2 IBP sensor off level Low Med High High Interval Lethal Arr off Disable Enable Med Interval Extended arrh Disable Enable Low Interval Alarm light on Alarm Reset On Off Reset Other Bed's alarms On Off Alarm delay Alarm reset by other bed On Off ST alarm delay Other bed disconnect On Off Latching Alarms.

2 Lethal Visual Audible Reminder Interval 1 min 2min 3min High Visual Audible Reminder tone On Off Re-alarm Medium Visual Audible Low Visual Audible Vtach Latch lock: Disable Enable Others Wave line Thin Med Thick ECG standard: AHA. Notch Freq 60 50. Nurse call set up: Data transfer Module USB Storage Off Signal type: Continuous Pulse Transfer data length 1hr 2hr 4hr 8hr All Contact type: Open Closed Transfer Strategy Ask Module Monitor Alarm level: High Med Low Apply module Settings On Off Alarm cat: Tech Phys SpO2 tone Mode1 Mode 2. Clear CMS IP at startup On Off DIAP Baud: 9600 19200 Config-influenced Settings Param switch On Off Factory Maintenance Central Hypervisor Panorama Network setup: HR alarm delay On Off Presence mode: Broadcast Multicast Device Config: 2 Color Alarm LED On Off HL7 Compatibility On Off P/N: 002-08-8026 Rev B Page 1 of 12.

3 Passport 12M/17M Bedside Monitor Default Settings Alarm Setup See Configurations Review Group: Standard Other _____. Custom List: Graphic Trends Zoom: 4min 8min 20min 40min 80min 2hr 4hr 8hr 16hr 32hr 64hr #Waves: Group: Standard Other _____. Tabular Trends Custom List: Interval: 5s 30s 1min 5min 10min 15min 30min 1hr 2hr 3hr NIBP. Disclosure Saved waves: Beat Annotation On Off Screen Setup Help On Off Sweep Refresh Sweep Key Volume(1-10) Brightness(1-10). Screen Layout (Normal/Big Numeric Setup--see Configurations). Minitrends Setup Parameter 1. Parameter 2. Parameter 3. Parameter 4. PP12/17. Factory Defaults Parameter 5. Parameter 6. Parameter 7. Parameter 8.

4 Parameter 9. PP17 Parameter10. Parameter11. Length: 30min 1hr 2hr 4hr 8hr OxyCRG Setup Time: 1 min 2 min 4 min 8 min Trend1: HR HR+RR. Trend2: SpO2 SpO2b SpO2 +SpO2b Compressed: Resp CO2. Factory Defaults Event: 1min+3min 2min+2min 3min+1min Scaling: HR: Upper_____ Lower_____. RR: Upper_____ Lower_____. SPO2: Upper_____ Lower_____. CO2: Upper_____ Lower_____. View Others Setup Alert tone: Repeat Once Off *12 Lead Setup Filter: Diagnostic ST 12 Lead Report Setup Baseline Drift: On Off Format: 12x1 6x2 3x4+1. Tachy High Factory Defaults Median Complex: On Off Brady Low Measurements: On Off QTc Formula: Interpretation: On Off Hodges Bazett Fridericia Framingham Interp Summary: On Off Waveform Layout: Standard Cabrera P/N: 002-08-8026 Rev B *Optional Page 2 of 12.

5 Passport 12M/17M Bedside Monitor Default Settings Screen Setup cont'd Measurement Color Setup Parameter Color Factory Default Adu Ped Neo ECG. White SPO2. Gray 1-3 IBP1. Red 1-3 IBP2. Orange 1-3 IBP3. Yellow 1-3 IBP4. Green 1-3 IBP5. Cyan 1-3 IBP6. Blue 1-3 IBP7. Purple 1-3. IBP8. Resp CO2. NIBP. Temp AA. O2. N2O. CO2 (AG). BIS. Night Mode Volume: NIBP End tone: On Off Brightness Alm QRS Key Stop NIBP. Record Setup Waveforms Wave 1. Wave 2. Factory Wave 3. Defaults IBP Overlap Length 8 sec Continuous Interval Off 10 min 15 min 20 min 30 min 40 min 50 min 1 hr 2 hr 3 hr 4 hr Paper Speed 25 mm/s 50 mm/s P/N: 002-08-8026 Rev B *Optional Page 3 of 12. Passport 12M/17M Bedside Monitor Default Settings Print Setup ECG Reports Normal End of Case Yes No Factory Amplitude 5mm 10mm 20mm 5mm 10mm 20mm Defaults Auto Interval On Off On Off Sweep 25mm/s 50mm/s 25mm/s 50mm/s 12 Lead 12x1 6x2 3x4+1 12x1 6x2 3x4+1.

6 Tabular Trends Normal End of Case Yes No Reports Back 30min 1hr 2hr 3hr 6hr 30min 1hr 2hr 3hr 6hr 12hr 24hr 48h 72hr 96hr 12hr 24hr 48h 72hr 96hr Auto All Auto All Spacing 5s 30s 1min 5min 5s 30s 1min 5min 10min 15min 30min 10min 15min 30min 1hr 2hr 3hr NIBP Auto 1hr 2hr 3hr NIBP Auto Factory Defaults Report layout Parameter oriented Time oriented Parameter oriented Time oriented Select Currently displayed Standard group Currently displayed Standard group parameters Custom List: Custom List: Graphic Trends Normal End of Case Yes No Reports 30min 1hr 2hr 3hr 6hr 30min 1hr 2hr 3hr 6hr Back 12hr 24hr 48h 72hr 96hr 12hr 24hr 48h 72hr 96hr Auto All Auto All 4min 20min 40min 2hr 4min 20min 40min 2hr 4hr Paginal Time Factory 4hr 8hr 16hr 32hr Auto 8hr 16hr 32hr Auto Defaults Currently displayed Standard group Currently displayed Standard group Select Custom List: Custom List: parameters Realtime Normal End of Case Yes No Reports 25mm/s 50mm/s 25mm/s 50mm/s Sweep Auto Auto Factory Current Current Defaults Select Wave Select waves List: Select waves List: Print Setup Printer Paper Size A4 Letter Print Both Sides On Off Mark Event Waveforms Wave 1.

7 Factory Wave 2. Defaults Wave 3. Analog Output Setup Analog out On Off Waveform ECG IBP IBP. P/N: 002-08-8026 Rev B *Optional Page 4 of 12. Passport 12M/17M Bedside Monitor Default Settings Parameters ECG Setup Alm Source ECG1. ECG2. ECG1 Gain ECG2 Gain Sweep 25mm/s 50mm/s Filter Diagnostic Monitor Surgery ST. Arrhythmia analysis See alarm setup ST analysis On Off QT analysis On Off Formula: Lead All Single: Others QRS Vol (0-10). Lead Set Adu: Auto 3 5 12 Ped: Neo: ECG Display Normal Full screen Half screen Notch Filter Off Weak Strong No Yes Pacer Reject On Off Paced Pace Rate (40-100). Smart Lead Off On Off QRS Threshold Resp Setup Apnea Delay Adu: 10 15 20 25 30 35 40 Ped: Neo: Resp Lead Adu: I II Auto Ped: Neo: Gain Sweep 3mm/s 25mm/s Detection mode Auto Manual RR Source Auto ECG CO2.

8 SpO2 Setup Massimo Nellcor Avg time: 2-4s 4-6s 8s 10s 12s 14s 16s Sat Sec: Sensitivity Mode: High Normal 0 10 25 50 100. NIBP Simul On Off Sweep 25mm/s 50mm/s PR source SpO2 IBP Art Auto Alm source HR PR Auto Beat vol (0-10). NIBP Setup Initial Pressure Adu: Ped: Neo: Adu: Manual 1m 2m 3m 5m 10m 15m 20m Interval 30m 1h 2h 3h 4h 8h Ped: Neo: End Tone On Off Clock On Off Venipuncture Adu: Ped: Neo: P1 Setup Label Scale Auto Manual Upper_____ Lower_____. Factory Sweep 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: P2 Setup Label Scale Auto Manual Upper_____ Lower_____. Factory Sweep 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: P/N: 002-08-8026 Rev B *Optional Page 5 of 12.

9 Passport 12M/17M Bedside Monitor Default Settings Parameters cont'd *P3 Setup Label Scale Auto Manual Upper_____ Lower_____. Factory Sweep 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: *P4 Setup Label Measure: All Mean Scale Auto Manual Upper_____ Lower_____. Factory Sweep 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: *P5 Setup Label Measure: All Mean Scale Auto Manual Upper_____ Lower_____. Factory Sweep 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: *P6 Setup Label Measure: All Mean Scale Auto Manual Upper_____ Lower_____. Factory Sweep 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: *P7 Setup Label Measure: All Mean Scale Auto Manual Upper_____ Lower_____.

10 Factory Sweep 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: *P8 Setup Label Measure: All Mean Scale Auto Manual Upper_____ Lower_____. Factory Sweep mm/s 25mm/s 50mm/s Defaults Filter 8Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: *CO2 Setup Apnea Delay Adu: 10 15 20 25 30 35 40 Ped: Neo: BTPS Comp On Off O2 Comp Sidestream N2O Comp Des Comp Factory Flow Rate 70 100 120 150 (ml/min). Defaults Oridion Max Hold Single 10 20 30. Op mode Standby Measure Wave type Draw Fill Scale Sweep 3 25 50 (mm/s). RR source Auto ECG CO2. Auto Standby Off 15min 30min 60min P/N: 002-08-8026 Rev B *Optional Page 6 of 12. Passport 12M/17M Bedside Monitor Default Settings Parameters cont'd *AG Setup Apnea Delay Adu: 10 15 20 25 30 35 40 Ped: Neo: Flow rate High Med Low Op mode Standby Measure CO2 Wave Type Draw Fill CO2 Scale mmHg kPA %.


Related search queries