Example: air traffic controller

Pentair IntelliFlo Variable Speed Pump Manual

IMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONSSAVE THESE INSTRUCTIONS(Compatible with IntelliComm communication center and EasyTouch , IntelliTouch and SunTouch control systems) IntelliFlo Variable Speed Programmable PumpInstallation andUser s GuideTable of Contents IntelliFlo Variable Speed Pump Installation and User s Guide iIf you have questions about ordering Pentair Water Pool and Spa ( Pentair ) replacement parts, and pool products, please use the following contact information:Customer Service / Technical SupportCustomer Service (8 to 5 Eastern and Pacific Times)Phone: (800) 831-7133 Fax: (800) 284-4151 Web sitevisit or to find information about Pentair products.

manual air relief valve in the open position and wait for all pressure in the system to be relieved. Before starting the system, fully open the manual air relief valve and place all system valves in the “open” position to allow water to flow freely from the tank and back to the tank. Stand clear of all equipment and start the pump.

Tags:

  Open, Manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Pentair IntelliFlo Variable Speed Pump Manual

1 IMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONSSAVE THESE INSTRUCTIONS(Compatible with IntelliComm communication center and EasyTouch , IntelliTouch and SunTouch control systems) IntelliFlo Variable Speed Programmable PumpInstallation andUser s GuideTable of Contents IntelliFlo Variable Speed Pump Installation and User s Guide iIf you have questions about ordering Pentair Water Pool and Spa ( Pentair ) replacement parts, and pool products, please use the following contact information:Customer Service / Technical SupportCustomer Service (8 to 5 Eastern and Pacific Times)Phone: (800) 831-7133 Fax: (800) 284-4151 Web sitevisit or to find information about Pentair products.

2 *Technical SupportSanford, North Carolina (8 to 5 ET)Phone: (919) 566-8000 Fax: (919) 566-8920 Moorpark, California (8 to 5 PT)Phone: (805) 553-5000 (Ext. 5591)Fax: (805) 553-5515 Priming the pumpExternal Control with IntelliComm Communication CenterConnecting the pump to EasyTouch and IntelliTouch SystemsConnecting the pump to a SunTouch SystemUser Maintenance ..Pump Strainer BasketPump Strainer Basket ServiceMotor ServiceWinterizingPriming the pump after serviceInstallation and Removal .. IntelliFlo Variable Speed Kit ContentsInstalling the IntelliFlo LocationPipingElectricalWiring the IntelliFlo PumpGround Wire ConnectionPump DisassemblyShaft Seal ReplacementPump Reassembly/Installing New SealDrive Assembly Removal and InstallationTroubleshooting.

3 Alerts and WarningsGeneral IntelliFlo Troubleshooting ProblemsReplacement Parts ..Illustrated Parts ListIntelliFlo Pump DimensionsIntelliFlo Flow and Power vs Flow Pump CurveIntelliFlo Electrical SpecificationsImportant Pump Warning and Safety Instructions ..Pump Overview .. IntelliFlo PumpExternal Control FeaturesIntelliFlo Drive Assembly and Control PanelIntelliFlo Motor Features Operating the Control Panel .. IntelliFlo Operator Control PanelControls and LEDsOperating the Pump ..Starting and stopping the pump Operating the Pump at Preset SpeedsPump Operating ModesProgramming the PumpIntelliFlo Variable Speed Pump MenusSettings: Pump AddressSettings: Set TimeSettings: Set AM/PM or 24 ClockSettings: Set Temperature UnitSettings: Screen Contrast LevelSettings: LanguageSettings: Set Minimum Speed (RPM)Settings: Set Maximum Speed (RPM)Settings: PasswordPassword ProtectionSpeed 1-8 (Schedule a Time to Run the Pump) External ControlFeatures: Quick CleanProgramming for Constant RunFeatures.

4 Time OutPriming Disable Priming Feature on the PumpAntiFreezeii111233444666778991010101 1111112121415151516171920222324262727272 8292930303030303031313233333435353638383 93939P/N 354604 Rev. C 4/19/12 *Spanish versions of this Manual are available online at / La versi n en espa ol de este Manual del producto, se puede encontrar en l nea a: Variable Speed Pump Installation and User s Guide iiIMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, include the following:Do not permit children to use this unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter Risk of Electrical Shock.

5 Connect only to a branch circuit protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI. (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump.

6 Disconnect the pump and have the problem corrected by a qualified service representative before pump is for use with permanent swimming pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original pump is for use with permanent swimming pools and may also be used with hot tubs and spas if so marked.

7 Do not use with storable pools. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original Warningss .EVER open THE INSIDE OF THE DRIVE MOTOR ENCLOSURE 4 HERE IS A capacitor bank that holds a 230 VAC charge even when there is no power to the 4HE PUMP IS NOT SUBMERSIBLE s 4HE PUMP IS CAPABLE OF HIGH mOW RATES USE CAUTION WHEN INSTALLING and programming to limit pumps performance potential with old or questionable #ODE REQUIREMENTS FOR THE ELECTRICAL CONNECTION DIFFER FROM STATE TO STATE )NSTALL EQUIPMENT IN ACCORDANCE WITH THE.

8 ATIONAL %LECTRICAL Code and all applicable local codes and "EFORE SERVICING THE PUMP SWITCH /&& POWER TO THE PUMP BY disconnecting the main circuit to the 4 HIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS INCLUDING CHILDREN OF reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their !),52% 4/ &/,,/7 !,, ).3425#4)/.3 !.$ 7!2.).'3 #!. 2%35,4 ). 3%2)/53 "/$),9 ).*529 /2 $%!4( THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER S Manual BEFORE USING THIS PUMP.

9 THESE WARNINGS AND THE OWNER S Manual MUST BE LEFT WITH THE POOL #4)/. %.42!0-%.4 (!:!2$ 34!9 /&& 4(% -!). $2!). !.$ !7!9 &2/- !,, 35#4)/. /54,%43 4(% 53% /& 5.!002/6%$ #/6%23 /2 !,,/7).' 53% /& 4(% 0//, /2 30! 7(%. #/6%23 !2% -)33).' #2!#+%$ /2 "2/+%. #!. 2%35,4 ). "/$9 /2 ,)-" %.42!0-%.4 (!)2 %.4!.',%--%.4 "/$9 %.42!0-%.4 %6)3#%2!4)/. !.$ /2 $%!4( The suction at a drain or outlet can cause:Limb Entrapment: When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling. This hazard is present when a drain cover is missing, broken, loose, cracked or not properly Entanglement: When the hair tangles or knots in the drain cover, trapping the swimmer underwater.

10 This hazard is present when the flow rating of the cover is too small for the pump or Entrapment: When a portion of the body is held against the drain cover trapping the swimmer underwater. This hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or : When a person sits on an open pool (particularly a child wading pool) or spa outlet and suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the drain cover is missing, loose, cracked, or not properly ()3 05-0 02/$5#%3 ()'( ,%6%,3 /& 35#4)/. !.$ #2%!4%3 !