Example: bachelor of science

Portable Clamp-on Ultrasonic Flowmeter

EESIFLO 6000 SeriesDescription Our range of non-invasive flowmeters utilisesultrasonic technology for the accurate flow measurementof liquids in full Portable device has been designed to meet the needsof the Service/Maintenance and Commissioning Engineerwishing to check the flow rate of liquids at different locationsin the plant. The set-up of the unit is simple and userfriendly in order to obtain the required flow information measurement of flow is based on the principle thatsound waves are influenced by a flowing are made by penetrating the pipe withultrasound and subsequently time differences, frequencyvariations and phase shifts of the Ultrasonic signals Ultrasonic sensors are clamped onto the outside ofthe pipe , thus eliminating the need to dismantle thepipework and interrupt the process. The EESIFLO 6000 Series can be applied to any type of standard pipe carryingclean or dirty Low installation effort and costs Dual measur ing mode (transit-time and doppler) measurement is independent of fluid conductivity andpressure No pressure loss, no possibility of leakage Retrospective installation f or existing plants possib le No cutting of pipes necessar y, no interruption ofprocess, no plant shut down No additional fittings for maintenance required Hygi

EESIFLO 6000 Series Description Our range of non-invasive flowmeters utilises ultrasonic technology for the accurate flow measurement of liquids in full pipes .

Tags:

  Measurement, Ultrasonic, Flows, Pipe, Full, Accurate, Accurate flow measurement, In full pipes

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Portable Clamp-on Ultrasonic Flowmeter

1 EESIFLO 6000 SeriesDescription Our range of non-invasive flowmeters utilisesultrasonic technology for the accurate flow measurementof liquids in full Portable device has been designed to meet the needsof the Service/Maintenance and Commissioning Engineerwishing to check the flow rate of liquids at different locationsin the plant. The set-up of the unit is simple and userfriendly in order to obtain the required flow information measurement of flow is based on the principle thatsound waves are influenced by a flowing are made by penetrating the pipe withultrasound and subsequently time differences, frequencyvariations and phase shifts of the Ultrasonic signals Ultrasonic sensors are clamped onto the outside ofthe pipe , thus eliminating the need to dismantle thepipework and interrupt the process. The EESIFLO 6000 Series can be applied to any type of standard pipe carryingclean or dirty Low installation effort and costs Dual measur ing mode (transit-time and doppler) measurement is independent of fluid conductivity andpressure No pressure loss, no possibility of leakage Retrospective installation f or existing plants possib le No cutting of pipes necessar y, no interruption ofprocess, no plant shut down No additional fittings for maintenance required Hygienic measurement , no risk of contamination,suitable for ultra clean liquids No contact with medium, no risk of corrosion whenused with aggressive media Cost advantages when used with large diameterpipes, high pressure systems, etc.

2 Portable dual mode flo wmeter Easy to install c lamp-on sensorswith no pr ocess interruption Non-invasive flow measurement ofliquids, no pipeline disturbance, nopressure loss Suitable f or all commonly used pipematerials with pipe diameter s fr om6 mm to m (1/4" to 256") Integrated wall thic kness measure-ment, 2 flow channelsSpecificationGeneralMeasuring principle : Ultrasonic time diff erencecorrelation principle anddopplerFlow velocity .. 25 m/ cm/ % of measured value m/sAccuracy:Volume flow 1 .. 3 % of measured v aluedepending on application, % of measured value withprocess calibr ationFlow velocity % of measured v alueTurn down ratio:1/200 Gaseous and solidcontent of medium:< 10 % of volumeFlow transmitterEnclosure:PortableDegree of protection:IP 54 according EN 60529, IP 68optionalOperatingtemperature:-10 .. 60 C (14 .. 140 F)Housing material : Aluminium, powder coatedFlow channels:2 Power supply:Internal recharable battery, 6 V/4Ah, or external power supply 15 V DCOperating time:> 14 h with fully charged batteryDisplay:2 x 16 digit LCD, dot matrix,backlitDimensions:H 118 x W 276 x D 310 mm(with handle) kgPower consumption:< W in measurement modeSignal damping : 0.

3 60 s, configurablePortable Clamp-on Ultrasonic FlowmeterFlow transmitter (cont.)Response time: 1 s, 70 ms optionalMeasuring cycle: 100 .. 1000 Hz, single channelCalculation functions : Average/difference/sumOperating languages : Selectable between Danish,English, German, French,Dutch, Norwegian, Polish,Czech, TurkishQuantity and units of measurementVolumetric flow rate : m3/h, m3/min, m3/s, l/h, l/min, l/s,USgph, bls/d (barrels per day)Flow velocity: m/s, inch/sMass flow rate: g/s, t/h, kg/h, kg/minVolume: m3, l, gal (gallons)Mass: g, kg, tHeat flow: W, kW, MW (only with heatquantity measurement option)Heat quantity: J, kJ, MJ (only with heat quantitymeasurement option)Internal data loggerClamp-on sensorsType M2N, M2 ERated (possible)diameter range: (50) 100 .. 6500 mmDimensions: 60 x 30 x 34 mmMaterial: Stainless steelTemperature range:M2N -30 .. 130 C (-22 .. 266 F)M2E -30.

4 200 C (-22 .. 392 F), for short periods up to300 C (572 F)Degree of protection : IP 65 acc. EN 60529, IP 68optionalType Q3N, Q3 ERated (possible)diameter range: (10) 25 .. 400 (1000) mmDimensions: 43 x 18 x 22 mmMaterial: Stainless steelTemperature range:Q3N -30 .. 130 C (-22 .. 266 F)Q3E -30 .. 200 C (-22 .. 392 F), for short periods up to300 C (572 F)Degree of protection : IP 65 acc. EN 60529, IP 68optionalSpecial Clamp-on sensorsType S2N: For very small pipediameters 6 .. 40 (100) mmOther types: On requestWall thickness measurementMeasuring range: .. 200 mmResolution: mmLinearity: mmTemperature range: Standard version -20 .. 60 CHigh temperature version0 .. 200 C, for short periods upto 540 CAccessories External power supply 230 V, 50Hz/12 V, A; IP 30 Car power adapter 12 V, 2 A Leather carying case 330 x 340 x 220 mm Cable extension 3 m, 5 m, 10 m or 20 m Sensor positioning rail for sensors type Q3, stainlesssteel V2A External printer, ink jet 192 dpiStorage capacity: approx.

5 27,000 (optional> 100,000) measuring valuesLogging data: All measured and totalisedvalues, parameter setsCommunicationSerial interface: RS 232 Data:Instantaneous measured value,parameter set and configuration,logged dataSoftware EESIDATAF unctionality: Downloading of measuredvalues/parameter set, graphicalpresentation, list format, exportto third party software, on-linetransfer of measured dataOperating systems: WindowsTM , 95, 98, NTProcess inputs: Galvanically isolated from mainelectronics Temperature: PT 100, four-wire circuit,measuring range - 50 .. 400 CCurrent: 0 .. 20 mA; Ri = 50 Voltage: 0 .. 1 V; Ri = 1 M Process outputs: Galvanically isolated from mainelectronicsCurrent: 0/4 .. 20 mA; passive (Uext < 24V) or active (Rext < 500 )Voltage: 0 .. 1 V or 0 .. 10 V, Ri = 500 Frequency: 0 .. 1 kHz or 0 .. 10 kHz; (OC)Digital (pulse, status) : Totaliser value .. 1000 /unit; width 80.

6 1000 ms; (OC/Reed)Reed = Reed-NO contact (300 V/ A)OC = Open-CollectorPortable flow transmitterEESIFLO 6000 SeriesExternal dimensionsClamp-on sensors type Q3N-7-P002 Clamp-on sensors type M2N-7-P003