Example: air traffic controller

Potential Transformer - Ferraz Fuses

Potential Transformer Amp-Trap and 9F60 Series PT Fuses . and ferrule mounted Fuses : Mersen PT Fuses are current-limiting Fuses with high interrupting rating, used for the primary winding protection of Potential Transformer . They are small dimension ferrule type Fuses and mount in standard clips. Current ratings are from to 5A. Features/Benefits: Ferrule mounting for standard clips and interchangeability with other brands of Fuses . Current-limiting for superior equipment protection. Non-venting for silent operation. Metal embossed catalog number and manufacturing date for lasting identification.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search. E35 E 7.2kV / 8.25kV / 15.5kV Ferrule mounted fuses:

Tags:

  Potential, Transformers, Potential transformer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Potential Transformer - Ferraz Fuses

1 Potential Transformer Amp-Trap and 9F60 Series PT Fuses . and ferrule mounted Fuses : Mersen PT Fuses are current-limiting Fuses with high interrupting rating, used for the primary winding protection of Potential Transformer . They are small dimension ferrule type Fuses and mount in standard clips. Current ratings are from to 5A. Features/Benefits: Ferrule mounting for standard clips and interchangeability with other brands of Fuses . Current-limiting for superior equipment protection. Non-venting for silent operation. Metal embossed catalog number and manufacturing date for lasting identification.

2 Ratings: Blown-fuse indicator to give positive identification of open fuse fuse is available on Amp-Trap the 9F60 series. A240T. Volts : AC. Amps : to 5A. Applications: IR : 50kA Sym Primary protection for Potential transformers (PT) or control power A480T. transformers (CPT). Volts : AC. Amps : to 5A. IR : 50kA Sym A500T. Volts : AC. Length Amps : to 5A. IR : 50kA Sym Clip Centers A720T. Volts : AC. Amps : to 3A. IR : 50kA Sym Diameter 9F60 Series EJ-1. 9F60A. Volts : .625kV AC. Amps : 3 to 5A. Ferrule IR : 100kA Sym Length 9F60B.

3 Volts : AC. : AC. : AC. : AC. Amps : to 3A. IR : 60kA Sym : 80kA Sym : 120kA Sym E32. Potential Transformer Amp-Trap and 9F60 Series PT Fuses / / Ferrule mounted Fuses : Potential Transformer Fuses Amp-Trap Series (227 mm) Clip Centers Amp Diameter Length Ferrule Length Max Max IR RMS Spare Parts Spare Parts Fuse Support Catalog No. Indicating Rating Inches (mm) Inches (mm) Inches (mm) Voltage Sym (Clips*) (Live Parts) Indoor (EK-1). A720T1/2E-1 A720T3/4-1 A720T1E-1 1A No ( ) (241) ( ) 50kA C08917P . A720T2E-1 2A. A720T3E-1 3A. Potential Transformer Fuses 9F60 Series, EJ-1.

4 (206 mm) Clip Centers E. Amp Diameter Length Ferrule Length Max Max IR RMS Spare Parts Spare Parts Fuse Support Catalog No. Indicating Rating Inches (mm) Inches (mm) Inches (mm) Voltage Sym (Clips*) (Live Parts) Indoor (EK-1). 9F60 BDE905 9F60 BDE001 1A. Yes ( ) (241) ( ) kV 80kA 9F61 BWW460 9F61 BNW450 9F61 ABG101. 9F60 BDE002 2A. 9F60 BDE003 3A. Potential Transformer Fuses 9F60 Series, EJ-1. (292 mm) Clip Centers Amp Diameter Length Ferrule Length Max Max IR RMS Spare Parts Spare Parts Fuse Support Catalog No. Indicating Rating Inches (mm) Inches (mm) Inches (mm) Voltage Sym (Clips*) (Live Parts) Indoor (EK-1).

5 9F60 BHH905 9F61 ADG101. 9F60 BHH001 1A ( nominal - 95. 9F60 BHH002 2A kV BIL). Yes ( ) (327) ( ) kV 120kA 9F61 BWW460 9F61 BNW450. 9F61 ADJ101. 9F60 BHH003 3A ( nominal - 110kV. BIL). *Use two clips per fuse For the most current product performance data visit and use catalog search. E35.


Related search queries