Example: tourism industry

PR 1613 System Weighing Indicator - WESICO.CZ

Technical DataHousing (PR 1613 /01)Material: aluminiumProtection class: IP 30 Front panel: IP 65 Housing (PR 1613 /04)Material: stainless steelProtection class: IP 65 Main voltagePR 1613/00 and PR 1613/03:110 V/220 VAC, -15%/+10%, 50/60 HzPR 1613/01 and PR 1613/04:24 VAC-15 %/+10 %,24 VDC-15 %/+20 %Power consumption19 W / 25 VA(PR 1613/00)18 W / 24 VA(PR 1613/01) W / 30 VA(PR 1613/03)23 W / 30 VA(PR 1613/04) Indicator specific features Free programmability of internal PLC andweighing sequences Easy connection of barcode reader, remotedisplays, printers or PLCs Load cell supply of 12 V or 20 V Automatic zero tracking Multi-range scales possible (3 ranges) SW- and HW options later on extendable Disabling keyboard functions Analogue testCustomer specific benefits Easy and comfortable operating,calibration and configuration Calibration without weights(input of load cell identification data)

M.T.B.F. 35000 hours Status indicators->0<- zero display within = 1/4 d standstill B gross weight display NET net weight display T tare weight display

Tags:

  System, Indicator, Weighing, 3116, Pr 1613 system weighing indicator, Standstill

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PR 1613 System Weighing Indicator - WESICO.CZ

1 Technical DataHousing (PR 1613 /01)Material: aluminiumProtection class: IP 30 Front panel: IP 65 Housing (PR 1613 /04)Material: stainless steelProtection class: IP 65 Main voltagePR 1613/00 and PR 1613/03:110 V/220 VAC, -15%/+10%, 50/60 HzPR 1613/01 and PR 1613/04:24 VAC-15 %/+10 %,24 VDC-15 %/+20 %Power consumption19 W / 25 VA(PR 1613/00)18 W / 24 VA(PR 1613/01) W / 30 VA(PR 1613/03)23 W / 30 VA(PR 1613/04) Indicator specific features Free programmability of internal PLC andweighing sequences Easy connection of barcode reader, remotedisplays, printers or PLCs Load cell supply of 12 V or 20 V Automatic zero tracking Multi-range scales possible (3 ranges) SW- and HW options later on extendable Disabling keyboard functions Analogue testCustomer specific benefits Easy and comfortable operating,calibration and configuration Calibration without weights(input of load cell identification data)

2 Operator dialogue in local language Print layout adjustable Typical weighbridge, batching andOn-Board Weighing software availableProfileThe weight indicators PR 1613 have beendesigned for high precision weighingapplications for platforms,weighbridges, cranes or batching via: front panel control inputs/outputs remote display/terminal communication from a supervisory System (Dust, JBUS/MODBUS, Teleperm,Profibus-DP)In case of alpha numerical operation as forplatforms or batching processes it isrecommandable to use the compactweighing 1613 System Weighing Indicator High accuracy W&M indicators ECconformity certificate 5000 d EN 4550l (corresp. to OIML R 76) Alibi memory for W&M Free programmable Integrated PLC, 6 inputs and 12 outputs Max. 4 serial interfaces (current loop,RS 232 or RS 422/485) Optional: analogue inputs/putputs, BCD-output, Parallel printer interface, Pulsecounter input, PROFIBUS-DP Various software options for: Weighbridgeapplications, Batching applications,Communication protocols Real time clock and memory extension Protection class IP 65 (front) hoursStatus indicators->0<-zero display within = 1/4 dstandstillBgross weight displayNETnet weight displayTtare weight displayDimensions can be set for: g, kg, t,lbDecimal point can be setDisplayType: vacuum fluorescent displayElements: 7 - digits (7 segments)Height: mmColour: bright greenplus Weighing and status symbolsMessage display(only PR1613 )2 lines with 20 charactersStructure: 5 x 7 MatrixControl inputNumber: 6, opto-isolatedMax.

3 Voltage 32 VDCI nput current (high):5 mA at 12 VDC/11 mA at 24 VDCC ontrol outputsNumber: 12, opto-isolated outputMax. voltage: 32 VDCMax. current: 75 mAAccuracy5000e class III acc. to EN 45 501; corresponds to OIML R 76 Load cell connectionAll strain gauge loadcells;6- or 4-wire connectionLoad cell supply12 V/20 VDCselectable, short-circuitproof. External load cell supply is load impedance(internal supply)min. 6 load cells with 600 or 4 load cells with 350 Measuring principleMeas. amplifier: integrating converter,ratiometric to LC supplyConversion time 50 time: s to 2 s, can be set at intervals of rangeMeas. signal: mV to 36 mV(for 100 % nominal load)Dead load: mVThere is no interaction between dead loadand measuring range (internal) V / div.(max. 180,000 counts)Analog filterActive Butterworth low pass filter,40 dB / decade, 2 Hz cut-off frequencyLinearity< %Temperature effectsZero: < V / K RTISpan: < % / 10 KEnvironmental conditionsVibration safetyAcc.

4 To IEC 68-2-6. Test FcStatic dischargeAcc. to IEC 1000-4-2 Interference on mains and input/outputAcc. to IEC 1000-4-4 Electromagnetic fieldAcc. to IEC 1000-4-3 26 MHz to 1 GHz Radio noise suppressionAcc. to EN 55 011 Electrical safetyAcc. to IEC IEC 1010-1 TemperatureW&M operation: -10 C to +40 Cindustrial: -10 C to +55 CStorage: -40 C to +70 C PR 1613/80 Memory extension PR 1613/81 Alibi memory (Weights and Measures)In/OutputsFree programmable with SW-OptionPR 1613/10 or PR 1613/2012 Outputs 6 inputsOptionsup to 6 Load CellsPR 1609/00 Real time clockruns independently of mains(for PR 1613/03 standard)PR 1613 Function Diagram PR 1603/00 Double interface RS 232 + TTY PR 1605/00 Parallel printer interface PR 1606/000-10 V, 0-20 mA or 2-10 V, 4-20 mA Analog output PR 1606/8xAnalog / BCD output (only 1 serial line possible) PR 1607/004 Analoge inputs 0-10 V or 0-20 mA(only usable with PR 1613/10 or PR 1613/20) PR 1608/xx5 Decade BCD - output,(with PR 1613/10 or PR 1613/20 usable as 24 additional outputs) PR 1610/00 Pulse counter input(optional 7 additional inputs available)

5 PR 1621/00 PROFIBUS-DPSerial lines PR 1601/00 TTY PR 1602/00 RS 232 (V24) PR 1604/00 RS 422/RS 485SW Option PR 1613/10 Standard packagefor weightbridges Programming facilities ofthe internal PLC andweighing sequencesorSW Option PR 1613/20 Standard programm for batching Programming facilitiesof the internal PLC andweighing sequencesorSW Option PR 1613/30 On board weighingextension Tilling correctionfor truck mountedweighing systems SW Option PR 1613/05 Different communicationprotocols are available: DUST 3964 R TELEPERM JBUS/MODBUSC able Junction BoxStandard Funciotns by use of WeighbridgeSoftware PR 1613/10 record the charge/discharge weight withsaving of the data editing of:- customers tables- vehicles tables- material tables print of customers lists material quantityper customer create or delete a list of all the vehicles onthe siteHaszardous areasafe areaPR 1625/60 TTYRS 232RS 232RS 485 Supervisory SystemPR 6130 IAIBCard ReaderPrinter FX 880 Typical application by use of batching software PR 1613/20 Typical application by use of weighbridge programm PR 1613 VT FX 880 Remote PR 1627dig outputsPR 1613 1613 PR 1602/00RS 232orPR 1603/00RS 232 Card ReaderInterfaceInterfaceStandard Funciotns by use of WeighbridgeSoftware PR 1613/20 editing of.

6 - material tables- recipe tables batching process control with alarmsignals print of- batching-reports- production reports- material consumption reportsRemote Display2PR 1626/60 Standard I/O connection (including PR 1613/10)Output FunctionOutput FunctionInput Function1tare active7pass activeIset zero2within 1/4 d8minus sign when net display2set tare3standstill9within zero set range3reset tare4limit 110display dimmed4start print5limit 211analogue/load cell/memory error5switch display to gross6W&M not fulfilled12analogue test active6switch display to netOrder informationTypeDescriptionOrder numbers TypeDescriptionOrder numbersPR 1613/00 System Weighing indicator9405 116 13001PR 1613/03 Compact Weighing terminal9405 116 13031PR 1613/01in 24 VAC/DCversion9405 116 13011PR 1613/04in 24 VAC/DCversion9405 116 13041 Hardware OptionsPR 1601/00 Current loop TTY9405 316 01001PR 1608/00 BCD-output (open emitter)9405 316 08001PR 1602/00RS 232 (V24)9405 316 02001PR 1608/10 BCD-output (open collector)

7 9405 316 08101PR 1603/00RS 232 + TTY9405 316 03001PR 1609/00 Real time clock9405 316 09001PR 1604/00RS 422/4859405 316 04001PR 1610/00 Pulse counter9405 316 10001PR 1605/00 Parallel printer interface9405 316 05001PR 1613/80 Memory extension9405 316 13801PR 1606/00 Analogue output9405 316 06001PR 1613/81 Alibi-memory (W&M)9405 316 13811PR 1606/80 Analogue / BCD output9405 316 06801PR 1621/00 PROFIBUS-DP9405 316 21001(open emitter)PR 1606/81 Analogue / BCD output9405 316 06811PR 1623/10 Connecting cable9405 316 23101(open collector)PR 1607/00 Analogue input (4x)9405 316 07001PR 1623/20 Relay I/O module9405 316 23201PR 1623/30 Terminal I/O module9405 316 23301 Software OptionsPR 1613/10 Weighbridge-package9405 316 13101PR 1613/20 Batch-package9405 316 13201PR 1613/05 Communications-package9405 316 13051 Rear panel PR 1613/00 Rear panel PR 1613/03 and /04all dimensions in mmInstrument dimensionsPR 1613/00 and /01 Weight net kg / shipping kgWeight net kg / shipping kgSartorius Hamburg GmbHMeiendorfer Stra e 20522145 Hamburg, GermanyTel.

8 + + subject to changewithout in C9498 716 13011 Version connections PR 1613/03


Related search queries