Transcription of PR 1613 System Weighing Indicator - WESICO.CZ
1 Technical DataHousing (PR 1613 /01)Material: aluminiumProtection class: IP 30 Front panel: IP 65 Housing (PR 1613 /04)Material: stainless steelProtection class: IP 65 Main voltagePR 1613/00 and PR 1613/03:110 V/220 VAC, -15%/+10%, 50/60 HzPR 1613/01 and PR 1613/04:24 VAC-15 %/+10 %,24 VDC-15 %/+20 %Power consumption19 W / 25 VA(PR 1613/00)18 W / 24 VA(PR 1613/01) W / 30 VA(PR 1613/03)23 W / 30 VA(PR 1613/04) Indicator specific features Free programmability of internal PLC andweighing sequences Easy connection of barcode reader, remotedisplays, printers or PLCs Load cell supply of 12 V or 20 V Automatic zero tracking Multi-range scales possible (3 ranges) SW- and HW options later on extendable Disabling keyboard functions Analogue testCustomer specific benefits Easy and comfortable operating,calibration and configuration Calibration without weights(input of load cell identification data)
2 Operator dialogue in local language Print layout adjustable Typical weighbridge, batching andOn-Board Weighing software availableProfileThe weight indicators PR 1613 have beendesigned for high precision weighingapplications for platforms,weighbridges, cranes or batching via: front panel control inputs/outputs remote display/terminal communication from a supervisory System (Dust, JBUS/MODBUS, Teleperm,Profibus-DP)In case of alpha numerical operation as forplatforms or batching processes it isrecommandable to use the compactweighing 1613 System Weighing Indicator High accuracy W&M indicators ECconformity certificate 5000 d EN 4550l (corresp. to OIML R 76) Alibi memory for W&M Free programmable Integrated PLC, 6 inputs and 12 outputs Max. 4 serial interfaces (current loop,RS 232 or RS 422/485) Optional: analogue inputs/putputs, BCD-output, Parallel printer interface, Pulsecounter input, PROFIBUS-DP Various software options for: Weighbridgeapplications, Batching applications,Communication protocols Real time clock and memory extension Protection class IP 65 (front) hoursStatus indicators->0<-zero display within = 1/4 dstandstillBgross weight displayNETnet weight displayTtare weight displayDimensions can be set for: g, kg, t,lbDecimal point can be setDisplayType: vacuum fluorescent displayElements: 7 - digits (7 segments)Height: mmColour: bright greenplus Weighing and status symbolsMessage display(only PR1613 )2 lines with 20 charactersStructure: 5 x 7 MatrixControl inputNumber: 6, opto-isolatedMax.
3 Voltage 32 VDCI nput current (high):5 mA at 12 VDC/11 mA at 24 VDCC ontrol outputsNumber: 12, opto-isolated outputMax. voltage: 32 VDCMax. current: 75 mAAccuracy5000e class III acc. to EN 45 501; corresponds to OIML R 76 Load cell connectionAll strain gauge loadcells;6- or 4-wire connectionLoad cell supply12 V/20 VDCselectable, short-circuitproof. External load cell supply is load impedance(internal supply)min. 6 load cells with 600 or 4 load cells with 350 Measuring principleMeas. amplifier: integrating converter,ratiometric to LC supplyConversion time 50 time: s to 2 s, can be set at intervals of rangeMeas. signal: mV to 36 mV(for 100 % nominal load)Dead load: mVThere is no interaction between dead loadand measuring range (internal) V / div.(max. 180,000 counts)Analog filterActive Butterworth low pass filter,40 dB / decade, 2 Hz cut-off frequencyLinearity< %Temperature effectsZero: < V / K RTISpan: < % / 10 KEnvironmental conditionsVibration safetyAcc.
4 To IEC 68-2-6. Test FcStatic dischargeAcc. to IEC 1000-4-2 Interference on mains and input/outputAcc. to IEC 1000-4-4 Electromagnetic fieldAcc. to IEC 1000-4-3 26 MHz to 1 GHz Radio noise suppressionAcc. to EN 55 011 Electrical safetyAcc. to IEC IEC 1010-1 TemperatureW&M operation: -10 C to +40 Cindustrial: -10 C to +55 CStorage: -40 C to +70 C PR 1613/80 Memory extension PR 1613/81 Alibi memory (Weights and Measures)In/OutputsFree programmable with SW-OptionPR 1613/10 or PR 1613/2012 Outputs 6 inputsOptionsup to 6 Load CellsPR 1609/00 Real time clockruns independently of mains(for PR 1613/03 standard)PR 1613 Function Diagram PR 1603/00 Double interface RS 232 + TTY PR 1605/00 Parallel printer interface PR 1606/000-10 V, 0-20 mA or 2-10 V, 4-20 mA Analog output PR 1606/8xAnalog / BCD output (only 1 serial line possible) PR 1607/004 Analoge inputs 0-10 V or 0-20 mA(only usable with PR 1613/10 or PR 1613/20) PR 1608/xx5 Decade BCD - output,(with PR 1613/10 or PR 1613/20 usable as 24 additional outputs) PR 1610/00 Pulse counter input(optional 7 additional inputs available)
5 PR 1621/00 PROFIBUS-DPSerial lines PR 1601/00 TTY PR 1602/00 RS 232 (V24) PR 1604/00 RS 422/RS 485SW Option PR 1613/10 Standard packagefor weightbridges Programming facilities ofthe internal PLC andweighing sequencesorSW Option PR 1613/20 Standard programm for batching Programming facilitiesof the internal PLC andweighing sequencesorSW Option PR 1613/30 On board weighingextension Tilling correctionfor truck mountedweighing systems SW Option PR 1613/05 Different communicationprotocols are available: DUST 3964 R TELEPERM JBUS/MODBUSC able Junction BoxStandard Funciotns by use of WeighbridgeSoftware PR 1613/10 record the charge/discharge weight withsaving of the data editing of:- customers tables- vehicles tables- material tables print of customers lists material quantityper customer create or delete a list of all the vehicles onthe siteHaszardous areasafe areaPR 1625/60 TTYRS 232RS 232RS 485 Supervisory SystemPR 6130 IAIBCard ReaderPrinter FX 880 Typical application by use of batching software PR 1613/20 Typical application by use of weighbridge programm PR 1613 VT FX 880 Remote PR 1627dig outputsPR 1613 1613 PR 1602/00RS 232orPR 1603/00RS 232 Card ReaderInterfaceInterfaceStandard Funciotns by use of WeighbridgeSoftware PR 1613/20 editing of.
6 - material tables- recipe tables batching process control with alarmsignals print of- batching-reports- production reports- material consumption reportsRemote Display2PR 1626/60 Standard I/O connection (including PR 1613/10)Output FunctionOutput FunctionInput Function1tare active7pass activeIset zero2within 1/4 d8minus sign when net display2set tare3standstill9within zero set range3reset tare4limit 110display dimmed4start print5limit 211analogue/load cell/memory error5switch display to gross6W&M not fulfilled12analogue test active6switch display to netOrder informationTypeDescriptionOrder numbers TypeDescriptionOrder numbersPR 1613/00 System Weighing indicator9405 116 13001PR 1613/03 Compact Weighing terminal9405 116 13031PR 1613/01in 24 VAC/DCversion9405 116 13011PR 1613/04in 24 VAC/DCversion9405 116 13041 Hardware OptionsPR 1601/00 Current loop TTY9405 316 01001PR 1608/00 BCD-output (open emitter)9405 316 08001PR 1602/00RS 232 (V24)9405 316 02001PR 1608/10 BCD-output (open collector)
7 9405 316 08101PR 1603/00RS 232 + TTY9405 316 03001PR 1609/00 Real time clock9405 316 09001PR 1604/00RS 422/4859405 316 04001PR 1610/00 Pulse counter9405 316 10001PR 1605/00 Parallel printer interface9405 316 05001PR 1613/80 Memory extension9405 316 13801PR 1606/00 Analogue output9405 316 06001PR 1613/81 Alibi-memory (W&M)9405 316 13811PR 1606/80 Analogue / BCD output9405 316 06801PR 1621/00 PROFIBUS-DP9405 316 21001(open emitter)PR 1606/81 Analogue / BCD output9405 316 06811PR 1623/10 Connecting cable9405 316 23101(open collector)PR 1607/00 Analogue input (4x)9405 316 07001PR 1623/20 Relay I/O module9405 316 23201PR 1623/30 Terminal I/O module9405 316 23301 Software OptionsPR 1613/10 Weighbridge-package9405 316 13101PR 1613/20 Batch-package9405 316 13201PR 1613/05 Communications-package9405 316 13051 Rear panel PR 1613/00 Rear panel PR 1613/03 and /04all dimensions in mmInstrument dimensionsPR 1613/00 and /01 Weight net kg / shipping kgWeight net kg / shipping kgSartorius Hamburg GmbHMeiendorfer Stra e 20522145 Hamburg, GermanyTel.
8 + + subject to changewithout in C9498 716 13011 Version connections PR 1613/03