Example: quiz answers

Presentation, Zelio Relay - plug-in relays …

2 Presentation of the rangeThe RSB interface Relay range comprises: 1 12 A relays with 1 C/O contact , 16 A relays with 1 C/O contact and 8 A relays with 2 C/O Sockets with separate contact Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these modules are common to all A plastic maintaining clamp for all Clip-in legends for the sockets. Socket descriptionSockets with separate contact terminals (1)1 Connection by connector. 2 Five or eight female contacts for the Relay A fi xing hole for panel Location for protection Locking components for plastic maintaining Locating slot for mounting on 5 rail.

4 Relays for standard applications Control circuit voltage Sold in lots of Number and type of contacts - Thermal current (Ith) 1 C/O - 12 A 1 C/O - 16 A 2 C/O - 8 A

Tags:

  Zelio

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Presentation, Zelio Relay - plug-in relays …

1 2 Presentation of the rangeThe RSB interface Relay range comprises: 1 12 A relays with 1 C/O contact , 16 A relays with 1 C/O contact and 8 A relays with 2 C/O Sockets with separate contact Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these modules are common to all A plastic maintaining clamp for all Clip-in legends for the sockets. Socket descriptionSockets with separate contact terminals (1)1 Connection by connector. 2 Five or eight female contacts for the Relay A fi xing hole for panel Location for protection Locking components for plastic maintaining Locating slot for mounting on 5 rail.

2 (1) The inputs and outputs are separated from the Relay supply. General characteristicsConforming to standardsIEC/EN 61810-1, UL 508, CSA C22-2 n 14 Product certifi cationsUL, CSAA mbient air temperature around the deviceStorage C- + 85 Operation Cc - + 85, a - + 70 Vibration resistanceConforming to IEC/EN 60068-2-610 gn ( Hz)Degree of protectionConforming to IEC/EN 60529IP 40 Shock resistanceconforming to IEC/EN 60068-2-27 Opening5 gnClosing10 gnProtection categoryRT IMounting positionAnyInsulation characteristicsRated insulation voltage (Ui)

3 Conforming to IEC/EN 60947V400 Rated impulse withstand voltage (Uimp) ( s)Dielectric strength(rms voltage)Between coil and contacta V5000 Between polesa V2500 Between contactsa V1000 Contact characteristicsRelay typeRSB 1A120pp RSB 1A160ppRSB 2A080ppNumber and type of contacts1 C/O1 C/O2 C/OContact materialsAgNiConventional thermal current (Ith)For ambient temperature y 40 CA12168 Rated operational current in utilisation categoriesAC-1 and DC-1 Conforming to IECN/OA12168N/CA684 Switching currentMinimummA5 Switching voltageMaximumVa 400, c 300 MinimumV5 Nominal load (resistive)

4 A12 / 250 a V16 / 250 a V8 / 250 a VA12 / 28 c V16 / 28 c V8 / 28 c VSwitching capacityMaximumaVA300040002000cW33644822 4 MinimummW300 Maximum operating rateIn operating cycles/hourNo-load72 000 Under load600 Zelio Relay - plug-in relaysRSB interface relaysPresentation, characteristics535188123564 InputsOutputsRelay supply54152313923 Presentation:page 28201/2 References:page 28201/4 Characteristics:page 28201/2 Dimensions, schemes:page 28201/5 version: 123456789103 Contact characteristics (continued) Relay typeRSB 1A120pp RSB 1A160ppRSB 2A080ppMechanical durabilityIn millions of operating cycles30 Electrical durabilityIn millions of op.

5 CyclesResistive loadSee curves belowElectrical durability of contactsResistive load a Reduction coeffi cient for inductive load a (depending on power factor cos ) Maximum switching capacity on resistive load c A RSB 2A080pp B RSB 1A160pp C RSB 1A120pp. Durability (inductive load) = durability (resistive load) x reduction coeffi characteristicsAverage consumptionc W, a VADrop-out voltage threshold c Uc, a UcOperating time(response time)Between coil energisation and making of the On-delay contactams12cms9 Between coil de-energisation and making of the Off-delay contactams10cms4 Control circuit voltage UcV612244860110120220230240 Relay control voltage codesRDJDBDEDNDFD supplyAverage resistance at 20 C 10% 9036014405700750025 200 Operating voltage Relay control voltage codes B7E7 supply 60 HzAverage resistance at 20 C 15% 4001550 10 200 35 500 38 500 42 500 Operating voltage limitsMin.

6 50 HzV 9617618419260 Hz HzV 144264276288 Socket characteristicsSocket typeRSZ E1S35 MRSZ E1S48 MRelay types usedRSB 1A120pp RSB 2A080pp, RSB 1A160pp (1)Contact terminal arrangementSeparateWire connection methodConnectorProduct certifi cationseConforming to standardsIEC 61984, UL, CSAE lectrical characteristicsConventional thermal current (Ith)A12 Maximum operating voltageV300 Insulation characteristicsBetween adjacent output contactsVrms2500 Between input and output contactsVrms2500 Between contacts and 5 railVrms2500 General characteristicsAmbient air temperaturearound the deviceOperation C- + 85 Storage C- + 85 Degree of protectionConforming to IEC/EN 60529IP 20 Cablingscrew connector Solid cable without cable end1 mm2 - AWG 142 mm2 - AWG 16 Flexible cable with cable end1 mm2 - AWG 142 mm2 - AWG 17 Maximum tightening torque /

7 Screw / M3 screwMountingOn 35 mm 5 rail / on panelFixing on 5 railBy plastic compression springTerminal referencingIECBus jumper (Ith: 5 A)NoCompatibility with the metal maintaining clampYes, plasticTimer moduleNoProtection moduleAll RZM pppClip-in legendsYe sWire connection methodScrew connector(1) When using the Relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 28201 ,800,41,211,62107105106 CABD urability (Number of operating cycles)Switching capacity (kVA)1040,800,41,211,62107105106 CABD urability (Number of operating cycles)Switching capacity (kVA)0,30,50,610,40,20,40,60,81 Reduction coeffi cient (A)0,30,50,610,40,20,40,60,81 Reduction coeffi cient (A)

8 0,11216100 200 3001020 305058120,550 CBAC urrent cVoltage c0,11216100 200 3001020 305058120,550 CBAC urrent cVoltage cZelio Relay - plug-in relaysRSB interface relaysCharacteristics version: 123456789104 relays for standard applicationsControl circuit voltageSold in lots ofNumber and type of contacts - Thermal current (Ith)1 C/O - 12 A1 C/O - 16 A2 C/O - 8 AUnit reference (1)Unit reference (1)Unit reference (1)WeightVkgc 610 RSB 1A120RD RSB 1A160RD RSB 2A080RD 12 10 RSB 1A120 JDRSB 1A160 JDRSB 24 10 RSB 1A120 BDRSB 1A160 BDRSB 48 10 RSB 1A120 EDRSB 1A160 EDRSB 60 10 RSB 1A120 NDRSB 1A160 NDRSB 110 10 RSB 1A120 FDRSB 1A160 FDRSB 24 10 RSB 1A120B7 RSB 1A160B7 RSB 48 10 RSB 1A120E7 RSB 1A160E7 RSB 120 10 RSB 1A120F7 RSB 1A160F7 RSB 220 10 RSB 1A120M7 RSB 1A160M7 RSB 230 10 RSB 1A120P7 RSB 1A160P7 RSB 240 10 RSB 1A120U7 RSB 1A160U7 RSB 12 A.

9 A 300 VContact terminal arrangementConnectionRelay typeSold in lots ofUnit referenceWeightkgSeparateConnectorRSB 1A120pp 10 RSZ 1A160pp (2)RSB 2A080pp10 RSZ modulesDescriptionFor use withVoltageSold in lots ofUnit referenceWeightVkgDiodeAll socketsc circuitAll socketsa + green LEDAll socketsc + green LEDAll socketsc or a or a or a use withSold in lots ofUnit referenceWeightkgPlastic maintaining clampAll sockets10 RSZ R215 sockets10 RSZ (1) To order a Relay complete with socket (sold in lots of 20): add suffi x S to one of the following voltage codes JD, BD, B7, P7 or F7.

10 Example: RSB 2A080BD + RSZ E1S48M becomes RSB 2A080 RBS.(2) When using the Relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 28201 1A120JD + RZM 031 FPD + RSZ E1S35M560583 RSB 1A120JD + RZM 031 FPD + RSZ E1S35M560583 RSB 1A160BD + RSZ E1S48M560584 RSB 1A160BD + RSZ E1S48M560584 RSB 2A080BD + RSZ E1S48M560582 RSB 2A080BD + RSZ E1S48M560582 RSZ R215560585 RSZ R215560585 Zelio Relay - plug-in relaysRSB interface relaysReferencesPresentation:page 28201/2 References:page 28201/4 Characteristics:page 28201/2 Dimensions, schemes:page 28201/5 version.