Example: tourism industry

Product Catalog - Trane HK

March 2014 PKGP-PRC006-ENProduct CatalogKoolman Air-Cooled Chiller and Heat PumpCGAK cooling only /CGAR heat pumpModel:030~200R410A, 50Hz2 ContentsFeatures and Benefi t 3 Mechanical Specifi cations 4 Model Nomenclature 5 Performance Data 6 Dimensions 8 Service and Maintenance Space Requirement 12 Electrical Specifi cations 13 Water Pressure Drop Curve 143 Features and Benefi tsIntroductionUsing the leading high-effi ciency ermetic scroll compressor and evaporator technology, Koolman provides you a stable, reliable and highly effi cient operation. Matched with a large variety of fan coils of different sizes it can be widely used in top grade apartments, luxury villas, offi ce buildings, small-sized restaurants, retail stores and hotels to create a comfortable and delightful indoor appearanceKoolman boasts of its state-of-the-art appearance.

2 Contents Features and Benefi t 3 Mechanical Specifi cations 4 Model Nomenclature 5 Performance Data 6 Dimensions 8 Service and Maintenance Space Requirement 12

Tags:

  Product, Catalog, Product catalog

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Product Catalog - Trane HK

1 March 2014 PKGP-PRC006-ENProduct CatalogKoolman Air-Cooled Chiller and Heat PumpCGAK cooling only /CGAR heat pumpModel:030~200R410A, 50Hz2 ContentsFeatures and Benefi t 3 Mechanical Specifi cations 4 Model Nomenclature 5 Performance Data 6 Dimensions 8 Service and Maintenance Space Requirement 12 Electrical Specifi cations 13 Water Pressure Drop Curve 143 Features and Benefi tsIntroductionUsing the leading high-effi ciency ermetic scroll compressor and evaporator technology, Koolman provides you a stable, reliable and highly effi cient operation. Matched with a large variety of fan coils of different sizes it can be widely used in top grade apartments, luxury villas, offi ce buildings, small-sized restaurants, retail stores and hotels to create a comfortable and delightful indoor appearanceKoolman boasts of its state-of-the-art appearance.

2 The contemporary appearance, designed by expert designers, will be naturally integrated with the surrounding environment and will defi nitely display your prominent footprintAs a result of the particular slim design (standard type is 500mm thick while mini type is only 393mm thick), the unit can be installed directly on the veranda, rooftop or ground without the need to have aplant optionsUnit with pressurized water tank is available to meet various levelKoolman uses low noise fans and components to achieve its low noise installationEach chiller has factory charged oil and refrigerant for reducing fi eld labor and materials costs. All units are factory run tested. Only power supply and water piping are required to be connected on the friendly refrigerantAll models are charged with R410A of Cooling TowerHeat dissipation in the way of air cycle eliminates the need for cooling water tower.

3 Thus, not only does it save the cost and space for cooling tower it also eliminates water shortage Specifi cationsGeneralKoolman air-cooled liquid chiller is designed to couple with fan coil units and air handling units for residential and light commercial air conditioning applications. Units are composed of scroll compressor (s), plate type evaporator, fi nned-coppertube and aluminum condenser, axial fan assembly, expansion valve, four-way reversal valve (heat pump only), indoor Cooling/Heating control switch, water fl ow switch, fi lter dryer, sight-glass, built-in water pump, galvanized sheet metal housing with powder paint and factory mounted controls. Optional fi ttings include pressurized water tank on capacity range, units come with single or double scroll compressors to cater for changing demand and effi cient part load is a compact brazed plate heat exchanger with AISI 316 stainless plates and adapters.

4 A 20-mesh strainer is installed at the water inlet to protect the evaporator and unit against fouling. The strainer (factory provided, fi eld installed) can be removed for parts are fabricated to precision by state-of-the-art CNC machines. The frame design allows all panels to be removed for service without affecting the structure of the unit. The panels are made of galvanized steel plate with powder paint. All panels are internally insulated with single layer foam cell in order to reduce noise and pumpPump is Rotodynamic pumps and adopts a mechanical shaft seal. Motor is fan cooled (TEFC), 2-pole induction type. Pump is installed in the unit to save installation space and also to reduce noise and protection devicesThe controller contains all the basic electrical protection devices including electromagnetic switches, relays and current overload protectors.

5 The automatic control devices consist of high and low pressure switches, thermostatic and anti-freeze cutouts, which improve and protect the unit's normal addition, the preset low temperature protection command can start the machine automatically to protect the water pipes from microprocessor-based controllerPrecise temperature control of inlet chilled water, operation modes and system protection are provided by the long-range controller. In addition, the password can be set and any abnormal condition will be monitored and captured to facilitate quick repair and normal operation. In addition, the interlocking function of the two-way valve is condenserThe unit comes with air-cooled fi n-tube U or V shaped condensers. Copper tubes are of the 3/8" diameter, seamless type. Fins are aluminum with effi cient Wavy fi n. Copper tubes are expanded mechanically to bond with the fi ns for effective heat transfer.

6 Light-weight axial fl ow fan(s) is (are) driven by high effi ciency, low speed, low noise motor(s) to ensure quiet and reliable limitsCooling modeHeating modemini21 C-7 C max43 C21 CLeaving water temperatureCooling modeHeating modemini5 C40 Cmax15 C50 C5 Digit 1,2,3 CGA = Air-Cooled Chiller and Heat PumpDigit 4 Model K = Cooling Only R = Heat Pump Digit 5,6,7 Model 030 100 050 120 060 150 075 200 Digit 8 Power Supply 5 = 380V/50Hz/3ph (For Model 030,050,060,075,100,120,150,200) 6 = 220V/50Hz/1ph (For 030 with single compressor and 060 with double compressors)Digit 9 Manufacturing Code (defaulted by factory) R = R410 ADigit 10 Controller B=Microprocessor-based adjustable water temperature controllerDigit 11 Water Side Electric Heater N=None Digit 12 Service Sequence A=The fi rst timeDigit 13 Water Pump for Unit R=With Pump inside (standard) N=Without PumpDigit 14 Applicable Ambient Temperature R = Standard ambinent temperature/Blue-fi nDigit 15 Fitting Options N = None (Standard Unit)

7 Digit 16 Other option B = Export N15A16R14R13A12N11B10R958075605R4A3G2C1 Model Nomenclatures6 MmodelCGAR/K0305 RCGAR/K0306 RCGAR/K0505 RCGAR/K0605 RCGAR/K0606 RCooling Capacity Capacity SupplyV380-415V/50Hz/3220-240V/50Hz/1380 -415V/50Hz/3380-415V/50Hz/3220-240V/50Hz /1 CompressorNumber11112 Rated Current(C/H) Rotor CurrentA6013082100130 Power Input(C/H) Scroll compressorNumber21 Rated Water PumpNumber1 Rated Input type heat exchangerWater Flow (C/H)m3 DeviceOverheat protection, High and Low Pressure + + Dimensionsmm950*393*12851290*500*1900 Water Connection (FPT)inch1 1 1 1 1-1/4"Direction of ConnectionRightRightRightRightRight or LeftOperation WeightKg130131141149320 Mode Conditions (Evap. 12 C/7 C - Air. 35 C). Mode Condition (Evap. 40 C/45 C - Air. DB/WB 7 C/6 C). unit is tested under Data7 Mode Conditions (Evap.)

8 12 C/7 C - Air. 35 C). Mode Condition (Evap. 40 C/45 C - Air. DB/WB 7 C/6 C). unit is tested under DataMmodelCGAR/K0755 RCGAR/K1005 RCGAR/K1205 RCGAR/K1505 RCGAR/K2005 RCooling Capacity Capacity SupplyV380-415V/50HZ/3380-415V/50HZ/3380 -415V/50HZ/3380-415V/50HZ/3380-415V/50HZ /3 CompressorNumber12222 Rated Current(C/H) Rotor CurrentA11082100110140 Power Input(C/H) Scroll compressorNumber31222 Rated Water PumpNumber1 Rated Input type heat exchangerWater Flow (C/H)m3 DeviceOverheat protection, High and Low Pressure + + + + + + + + Dimensionsmm950*393*15901290*500*1900199 0*500*1900 Water Connection (FPT)inchInlet1-1/4" outlet1"1-1/4"1-1/4"1-1/4"1-1/2"Directio n of ConnectionRightRight or LeftRight or LeftFrontFrontOperation WeightKg2024495305405408 DimensionsMini casingCGAK/R-0305R/0306R/0505R/0605R (Unit: mm)CGAK/R-0705 R (Unit.

9 Mm) 1"Water outlet 1"Water inlet907409506701285402393 Mini-Koolman186647904023931590670950824 Mini-Koolman7321861 1/4 Water outlet1 1/4 Water inlet9 DimensionsStandard casingCGAK/R-0606R/1005R (Unit: mm)500501290 FPT 1 1/4"BWater inletPower cable inlet 40 Water outlet500190 09001000580 Drain waterFPT 1/2" B9975 FPT 1 1/4"B120155TM50 FPT 1-1/4"B75 FPT 1/2" B50019905801000900190 0500 Drain waterWater outletPower cable inlet 40 Water inletFPT 1-1/4"BTMTM12015599 CGAR/K-1205R(Unit:mm)10 DimensionsCGAR/K-2005R (Unit: mm)50 FPT 1-1/2"BFPT 1/2" outletDrain water 40 Water inletFPT 1-1/2"BTMTM125120909855001990 CGAR/K-1505R (Unit: mm)50 FPT 1-1/4"BFPT 1/2" B50019905801000900190 0500 Water outletDrain water 40 Water inletFPT 1-1/4"BTMTM1251209098511 Pressure water tank (Option Unit:mm)DimensionsInstallation Example PPMakeup water valve Drain ValveShut-off Electric heater Fan coil X4 Ta pwater Water drainage Direct return Reversed return Shockproof hose ThermometerAutomaticair vent Primary Unit pressurisedwater tankwater strainerflowswitchDescription of the principle of the pressurized water tank:1.

10 In order to avoid the pipe cracking due to the system over pressure resulting from the change of ambient temperature and also to avoid the water hammer in the pipes, a pressurized water tank shall be installed for In order to avoid the excessively high or low pressure in the pipe, an automatic feed water valve and an automatic drain valve are included in the pressurized water tank. The feed water pressure can be adjusted based on the fi eld An open expansion tank shall be installed at the highest position of : the automatic exhaust valve shall be set at the highest point of the piping SizeModelABCDE FGHWTANK-5470263230182254435415455 WTANK-12620400324162356569440475 Water Inlet( )Water Outlet( )Water Drainage( )HGFABDCE12 Unit: mmService and Maintenance Space Requirement3005001500300500 Mini-Koolman4030163045073016308504966407 4040306407404504962330640150640640950402 393 Installation dimensionsCGAR(K)0606R/1005 RAir DirectionCGAR(K)0305R/0306R/0505R/0605R/ 0755 RCGAR(K)1205R/1505R/2005R13 MODELP ower supply(V/Hz/Ph)Full load current of water pumpFLA(A)Full load current of chiller unitFLA(A)Rated current of the fan RLA(A) Minimum current of the water unit circuitMCA(A) Recommended fuse specifi cation REC(A) Maximum specifi cation of the fuse FMS(A) Minimum specifi cation of the power supply copper core wire diameter (mm2) 0305R380-415/50 The difference between the power voltage and the standard voltage shall not exceed 10 percent of the standard value.


Related search queries