Example: barber

Products Catalog - Fred C. Gilbert

1 atkomatic Products Division of CIRCLE SEAL CONTROLS, INC. 2301 Wardlow Circle, Box 3300, Corona, California 92880 Tel: (909) 270-6200 Fax: (909) 270-6201 Products Catalog 1999 Circle Seal Controls, atkomatic Products Division of CIRCLE SEAL CONTROLS, INC. 2301 Wardlow Circle, Box 3300, Corona, California 92880 Tel: (909) 270-6200 Fax: (909) 270-6201 Catalog Index Page INTRODUCTION product Line Overview ---------------------------------------- ---------------------- 4 How to Order Ordering Valves ---------------------------------------- --------------------- 5 Ordering Repair Kits ---------------------------------------- --------------- 6 Constructing Catalog Numbers.

3 ATKOMATIC Products Division of CIRCLE SEAL CONTROLS, INC.

Tags:

  Product, Catalog, Products catalog, Atkomatic

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Products Catalog - Fred C. Gilbert

1 1 atkomatic Products Division of CIRCLE SEAL CONTROLS, INC. 2301 Wardlow Circle, Box 3300, Corona, California 92880 Tel: (909) 270-6200 Fax: (909) 270-6201 Products Catalog 1999 Circle Seal Controls, atkomatic Products Division of CIRCLE SEAL CONTROLS, INC. 2301 Wardlow Circle, Box 3300, Corona, California 92880 Tel: (909) 270-6200 Fax: (909) 270-6201 Catalog Index Page INTRODUCTION product Line Overview ---------------------------------------- ---------------------- 4 How to Order Ordering Valves ---------------------------------------- --------------------- 5 Ordering Repair Kits ---------------------------------------- --------------- 6 Constructing Catalog Numbers ---------------------------------------- --- 7 product Matrix ---------------------------------------- -------------------------------- 10 product OFFERING Valve Series HS ---------------------------------------- ------------------------------------- 14 JJ

2 ---------------------------------------- ------------------------------------- 17 500 ---------------------------------------- ------------------------------------- 20 1000 ---------------------------------------- ------------------------------------- 24 2000 ---------------------------------------- ------------------------------------- 28 3000 ---------------------------------------- ------------------------------------- 32 4000 & 5000 ---------------------------------------- --------------------------- 37 6000 ---------------------------------------- ------------------------------------- 42 7000 ---------------------------------------- ------------------------------------- 46 8000 ---------------------------------------- ------------------------------------- 49 12,000 ---------------------------------------- ----------------------------------- 53 13,000 ---------------------------------------- ----------------------------------- 56 14.

3 000 ---------------------------------------- ----------------------------------- 61 15,400 ---------------------------------------- ----------------------------------- 64 15,800 ---------------------------------------- ----------------------------------- 68 16,000 ---------------------------------------- ----------------------------------- 71 30,400 ---------------------------------------- ----------------------------------- 76 30,800 ---------------------------------------- ----------------------------------- 82 35,800 ---------------------------------------- ----------------------------------- 87 40,000 ---------------------------------------- ----------------------------------- 91 50.

4 000 ---------------------------------------- ----------------------------------- 96 15-794 ---------------------------------------- ----------------------------------- 101 Options Catalog ---------------------------------------- ---------------------------------- 104 Project (special) ---------------------------------------- ------------------------ 107 3 atkomatic Products Division of CIRCLE SEAL CONTROLS, INC. 2301 Wardlow Circle, Box 3300, Corona, California 92880 Tel: (909) 270-6200 Fax.

5 (909) 270-6201 TECHNICAL INFORMATION Application Operational Pressures ---------------------------------------- ------ 110 Fluid Filtration Requirements ------------------------------------- 111 Ambient Air Temperature Requirements ------------------------ 111 Installation & General Information -------------------------------- 111 Coils Voltages, Part Numbers, Amps, Resistance --------------------- 112 Insulation Ratings ---------------------------------------- ----------- 115 Double Wound Coils Operation ---------------------------------- 116 Relays for Double Wound Coils ----------------------------------- 116 Coil Housings NEMA 1 ---------------------------------------- --------------------- 119 NEMA 4 ---------------------------------------- --------------------- 121 NEMA 7 ---------------------------------------- --------------------- 123 Hazardous Locations ---------------------------------------- ---------------- 125 Valve Sizing & Cv Flow Coefficients ------------------------------------ 126 Factory Leakage Standards

6 ---------------------------------------- -------- 128 Response Times & Life Cycle Capability -------------------------------- 130 Approvals , UL & CSA ---------------------------------------- -------------- 131 Position Indicator Switch Adjustment ------------------------------------ 133 Aligning Coil Housings ---------------------------------------- --------------- 134 Field Modifications Coil Changes ---------------------------------------- ---------------- 135 to & to -------------------------------------- 135 Other Modifications ---------------------------------------- -------- 135 Valve Operation Direct Lift, Normally Closed ------------------------------------ 136 Direct Lift, Normally Open -------------------------------------- 136 Pilot Operated, Normally Closed -------------------------------- 137 Pilot Operated, Normally Open ---------------------------------- 138 Semi Direct Lift, Normally Closed ------------------------------ 139 Semi Direct Lift, Normally Open -------------------------------- 140 3 Way, Direct Lift ---------------------------------------- ------- 141 35,000 Series.

7 Externally Piloted -------------------------------- 142 4 atkomatic Products Division of CIRCLE SEAL CONTROLS, INC. 2301 Wardlow Circle, Box 3300, Corona, California 92880 Tel: (909) 270-6200 Fax: (909) 270-6201 Overview of product Line 1. General - Solenoid valves to meet a wide variety of industrial applications - 2 position, 2 way valves (one 3-way valve) - Most are globe style valves with piston poppets (some barstock direct lift) - Gravity close - with spring and fluid pressure assist - Most are in-line mounted full ported using pipe threads - Many are available either normally open or normally closed - Built to handle all types of clean fluid including air, water, oil, steam, cryogenics, fuels, caustics, refrigerants, and solvents 2.

8 Performance Ranges - Pressure: vacuum to 10,000 psi - Fluid temperatures: -423F to + 500F (+750F some models) - Pipe sizes from 1/8" to 3" (Cv from .02 to 71 ) 3. Materials of Construction - 316 Stainless Steel & Naval Bronze or Brass - Seat material selection: Elastomer: Buna, Viton, EPR Plastic: Teflon, Kel-F Metal: Stainless, Brass 4. Actuators - Solenoids rated for continuous duty (operational pressure values for normally open valves are based on intermittent duty only) - Class H and class B available - Available with NEMA Type 1 housing - standard Type 4 housings - waterproof Type 7 and 9 housings explosion proof for hazardous locations 5 atkomatic Products Division of CIRCLE SEAL CONTROLS, INC.

9 2301 Wardlow Circle, Box 3300, Corona, California 92880 Tel: (909) 270-6200 Fax: (909) 270-6201 Valve Ordering Information atkomatic valves can be ordered from any of the Circle Seal distributors. A complete list of all authorized stocking distributors in on the Internet at There are 3 methods of ordering atkomatic solenoid valves: 1) Specifying the current Catalog number 2) Specifying the complete application information 3) For some older valves, referencing a serial number. Method 1 Specifying the current Catalog number This is the preferred method for ordering solenoid valves. These Catalog numbers are constructed as outlined in the product offering section and more detailed instructions are on pages 7 - 9.

10 Use of these Catalog numbers eliminates the need for communicating lengthy text describing all of the application information. Use of these Catalog numbers will facilitate order processing in the factory. Note that the same application information as described in method 2 must be obtained from the customer to create the Catalog number. Method 2 Specifying the complete application information 1. Valve type - normally open or normally closed. This is the position that the valve will return to when electricity is removed. 2. Pilot operated, direct lift of semi-direct lift. This selection can be made by reviewing the customer's application with regard to minimum pressure drop and flow requirements (see pages 12 and 13).


Related search queries