Example: dental hygienist

Proline Promag W 400 - Endress+Hauser

The flowmeter with integrated web server and a sensor with EN ISO 12944corrosion protectionApplication The electromagnetic measuring principle is unaffected bypressure, temperature and flow profile The specialist in the water and wastewater industry for themost demanding applicationsDevice properties International drinking water approvals Degree of protection IP68 (Type 6P enclosure) Approved for custody transfer to MI-001/OIML R49 Transmitter housing made of durable polycarbonate Same housing concept for compact/remote version Integrated data logger: measured values monitoringYour benefits For direct underground installation or permanentunderwater use Safe, reliable long-term operation robust and completelywelded sensor Energy-saving flow measurement no pressure loss due tocross-section constriction Maintenance-f

The flowmeter with integrated web server and a sensor with EN ISO 12944 corrosion protection Application •The electromagnetic measuring principle is unaffected by pressure, temperature and flow profile •The specialist in the water and wastewater industry for the most demanding applications Device properties •International drinking water ...

Tags:

  Electromagnetic, Flowmeter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Proline Promag W 400 - Endress+Hauser

1 The flowmeter with integrated web server and a sensor with EN ISO 12944corrosion protectionApplication The electromagnetic measuring principle is unaffected bypressure, temperature and flow profile The specialist in the water and wastewater industry for themost demanding applicationsDevice properties International drinking water approvals Degree of protection IP68 (Type 6P enclosure) Approved for custody transfer to MI-001/OIML R49 Transmitter housing made of durable polycarbonate Same housing concept for compact/remote version Integrated data logger.

2 Measured values monitoringYour benefits For direct underground installation or permanentunderwater use Safe, reliable long-term operation robust and completelywelded sensor Energy-saving flow measurement no pressure loss due tocross-section constriction Maintenance-free no moving parts Safe operation no need to open the device due to displaywith touch control, background lighting Time-saving local operation without additional software andhardware integrated web server Integrated verification Heartbeat Technology ProductsSolutionsServicesTechnical InformationProline Promag W 400 electromagnetic flowmeterTI01046D/06/ Promag W 4002 Endress+HauserTable of contentsDocument and system.

3 6 Measured flow on flow cut assignment, device supply operating measured of ambient and outlet of connecting the wall-mount mounting temperature of compatibility (EMC).. temperature loss ..35 System transfer , tube and water instrument standards and device-dependent Promag W 400 Endress+Hauser3 Document informationSymbols usedElectrical symbolsSymbolMeaning A0011197 Direct currentA terminal to which DC voltage is applied or through which direct current flows.

4 A0011198 Alternating currentA terminal to which alternating voltage is applied or through which alternating current flows. A0017381 Direct current and alternating current A terminal to which alternating voltage or DC voltage is applied. A terminal through which alternating current or direct current flows. A0011200 Ground connectionA grounded terminal which, as far as the operator is concerned, is grounded via a groundingsystem. A0011199 Protective ground connectionA terminal which must be connected to ground prior to establishing any other connections.

5 A0011201 Equipotential connectionA connection that has to be connected to the plant grounding system: This may be a potentialequalization line or a star grounding system depending on national or company codes of for certain types of informationSymbolMeaning A0011182 AllowedIndicates procedures, processes or actions that are allowed. A0011183 PreferredIndicates procedures, processes or actions that are preferred. A0011184 ForbiddenIndicates procedures, processes or actions that are forbidden. A0011193 TipIndicates additional information. A0011194 Reference to documentationRefers to the corresponding device documentation.

6 A0011195 Reference to pageRefers to the corresponding page number. A0011196 Reference to graphicRefers to the corresponding graphic number and page in graphicsSymbolMeaning1, 2, 3,..Item numbers,..,Series of stepsA, B, C, ..ViewsA-A, B-B, C-C, ..Sections A0013441 Flow directionProline Promag W 4004 Endress+HauserSymbolMeaning- A0011187 Hazardous areaIndicates a hazardous A0011188 Safe area (non-hazardous area)Indicates a non-hazardous and system designMeasuring principleFollowing Faraday's law of magnetic induction, a voltage is induced in a conductor moving through amagnetic A0017035 UeInduced voltageBMagnetic induction (magnetic field)LElectrode spacingICurrentvFlow velocityIn the electromagnetic measuring principle, the flowing medium is the moving conductor.

7 Thevoltage induced (Ue) is proportional to the flow velocity (v) and is supplied to the amplifier by meansof two measuring electrodes. The flow volume (Q) is calculated via the pipe cross-section (A). The DCmagnetic field is created through a switched direct current of alternating for calculation Induced voltage Ue = B L v Volume flow Q = A vProline Promag W 400 Endress+Hauser5 Measuring systemThe device consists of a transmitter and a device versions are available: Compact version - the transmitter and sensor form a mechanical unit. Remote version the transmitter and sensor are mounted separately from one 400 Device versions and materials Compact version: compact housing Polycarbonate plastic Coated aluminum AlSi10Mg Remote version: wall-mount housing Polycarbonate plastic Coated aluminum AlSi10 MgConfiguration.

8 External operation via four-line, illuminated local display with touchcontrol and guided menus ("Make-it-run" wizards) for applications Via operating tools ( FieldCare) Via Web browser ( Microsoft Internet Explorer) Also for device version with EtherNet/IP output: Via Add-on Profile Level 3 for automation system from RockwellAutomation Via Electronic Data Sheet (EDS) A0017117 SensorPromag WNominal diameter range: DN 25 to 2000 (1 to 78")Materials: Sensor housing: coated aluminum AlSi10Mg, carbon steel withprotective varnish Sensor connection housing: coated aluminum AlSi10Mg, polycarbonate Measuring tube: stainless steel (304), (304L).

9 Forflanges made of carbon steel with Al/Zn protective coating orprotective varnish Liner: hard rubber, polyurethane Seals: as per DIN EN 1514-1 Electrodes: (304L), Alloy C22, tantalum Ground disks: (316L), Alloy C22, tantalumFixed flange: DN 25 to 300 (1 to12") A0017040 Fixed flange: DN 350 to 2000 (14to 78") A0017041 SafetyIT securityWe only provide a warranty if the device is installed and used as described in the OperatingInstructions. The device is equipped with security mechanisms to protect it against any inadvertentchanges to the device security measures in line with operators' security standards and designed to provide additionalprotection for the device and device data transfer must be implemented by the operators +Hauser can be contacted to provide support in performing this Promag W 4006 Endress+HauserInputMeasured variableDirect measured variables Volume flow (proportional to induced voltage) Electrical conductivityIn custody transfer.

10 Only volume flow and electrical conductivityCalculated measured variablesMass flowMeasuring rangeTypically v = to 10 m/s ( to 33 ft/s) with the specified accuracyElectrical conductivity: 5 to 10 000 S/cm/cmFlow characteristic values in SI unitsNominaldiameterRecommendedflowFacto ry full scale value(v ~ m/s)Full scale value currentoutput(v ~ m/s)Pulse value(~ 2 pulse/s)Low flow cut off(v ~ m/s)[mm][in][m3/h][m3/h][m3][m3/h]2519 to 300 dm3/min75 dm3 dm31 dm3/min32 15 to 500 dm3/min125 dm3/min1 dm32 dm3/min401 25 to 700 dm3/min200 dm3 dm33 dm3/min50235 to 1 100 dm3/min300 dm3 dm35 dm3/min65 60 to 2 000 dm3/min500 dm3/min5 dm38 dm3/min80390 to 3 000 dm3/min750 dm3/min5 dm312 dm3/min1004145 to 4 700 dm3/min1 200 dm3/min10 dm320 dm3/min125 220 to 7 500 dm3/min1 850 dm3/min15 dm330 dm3/min150620 to to 1 to 1 to 2 to 3 3001 to 4 2001 to 4 2001 to 5 4001 to 6 6002 to 9 6002 to 13 5003 to 15 0004 to 18 0004 to 22 5006 00040850 to 28 0007 0001125


Related search queries