Protection and Control IED ManagerPCM600 Getting Started Guide Protection and Control IED Manager PCM600 1 MRS756450 Issued: Version: 1 INSTALLATION GUIDE Related items PCM600 Ver. Installation CD PCM600 Ver. Setup can be downloaded from Content on CD PCM600 Setup PCM600 Ver. Readme file PCM600 Ver. Installation Guide PCM600 Ver. Product Guide PCM600 Setup includes the following software : Protection and Control IED Manager PCM600 Ver. Generic IEC 61850 IED Connectivity Package Ver. Adobe Reader XI Wavewin tool for Disturbance Analysis System requirements Operating system (32-bit versions): Windows XP SP3, Server 2003 SP2, Windows Vista SP2, Windows 7 (32-bit/64-bit), Windows 8 (32-bit/64-bit) Hardware requirements, minimum/recommended: Physical RAM memory: 2 GB / 3 GB Free hard disk space: 2 GB / 4 GB Processor: GHz / GHz Windows compatible pointer ( mouse) How to install PCM600 Ver.

PCM600 Setup includes the following software: ... available from Windows Update in Windows 8 and 8.1. Installing a Windows language pack in Windows 8 or 8.1 before installing the .NET Framework 3.5 ... The tool can also be used for connecting the LEDs on

Tags:

  Update, Software, Tool

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Protection and Control IED Manager PCM600 Getting Started ...

1 Protection and Control IED ManagerPCM600 Getting Started Guide Protection and Control IED Manager PCM600 1 MRS756450 Issued: Version: 1 INSTALLATION GUIDE Related items PCM600 Ver. Installation CD PCM600 Ver. Setup can be downloaded from Content on CD PCM600 Setup PCM600 Ver. Readme file PCM600 Ver. Installation Guide PCM600 Ver. Product Guide PCM600 Setup includes the following software : Protection and Control IED Manager PCM600 Ver. Generic IEC 61850 IED Connectivity Package Ver. Adobe Reader XI Wavewin tool for Disturbance Analysis System requirements Operating system (32-bit versions): Windows XP SP3, Server 2003 SP2, Windows Vista SP2, Windows 7 (32-bit/64-bit), Windows 8 (32-bit/64-bit) Hardware requirements, minimum/recommended: Physical RAM memory: 2 GB / 3 GB Free hard disk space: 2 GB / 4 GB Processor: GHz / GHz Windows compatible pointer ( mouse) How to install PCM600 Ver.

2 A) CD Installation: Insert the installation CD into the CD-drive. If the setup doesn t start automatically, execute in the root folder of the installation CD. b) Downloaded from ABB software Library: After free registration, you will get an email with a link to download the executable installation. Start the installation and follow the instructions. After the installation starts, select the needed soft-ware components and follow the instructions to complete the installation. PCM600 requires Microsoft SQL Server 2008 Express edition. The correct SQL Server instance will be installed automatically. If the correct SQL Server instance is already installed, the PCM600 installation will skip this step. The SQL Server requires Windows Installer and .NET Framework SP1, which will also be installed (on Windows XP/Server 2003/ Vista).

3 Windows Installer requires a reboot. When installing PCM600 on Windows 8 or , a network connection is mandatory. The reason for this is that .NET Framework SP1 is only available from Windows update in Windows 8 and Installing a Windows language pack in Windows 8 or before installing the .NET Framework will cause the .NET Framework installation to fail. Install the .NET Framework before installing any Windows language packs. Installation requires administrator rights. In all versions of Windows it might be necessary to switch off or configure antivirus software to not block the installation and operation of PCM600 ( McAfee Host Intrusion Prevention). Prerequisites for using PCM600 Ver. To operate with PCM600 , there must be at least one IED Connectivity Package installed and selected to be used with PCM600 Ver.

4 License There is no license required for PCM600 Ver. IEC 61850 communication configuration Separate IEC 61850 communication configuration software can be purchased through ABB sales representatives. Protection and Control IED ManagerPCM600 Product GuideContents1. Project Parameter Graphical application Signal Graphical display Hardware IED configuration Signal Event Disturbance Communication IEC 61850 Connectivity User Integrated help Data System Ordering Document revision information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for anyerrors that may appear in this document. Copyright 2013 rights is a registered trademark of the ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of theirrespective and Control IED Manager1 MRS756448 KPCM600 Product version: 2 ABB1.

5 DescriptionThe Protection and Control IED Manager PCM600 toolprovides versatile functionalities for the entire life-cycle of allRelion Protection and Control IED applications, at all voltagelevels. This easy-to-handle tool helps the user to manageyour Protection and Control equipment all the way fromapplication and communication configuration to disturbancehandling, including automatic disturbance to communicate, PCM600 interacts with IEDs overthe fast and reliable TCP/IP via corporate LAN or WAN, oralternatively directly through the communication port at thefront of the IED. PCM600 tool is able to read and write allconfiguration and setting data of an IED with a user interface, workflow and the IEC 61850-based datamodel in PCM600 are designed according to the samephilosophy as the Relion Protection and Control IEDs,ensuring smooth and seamless integration between the tooland the also secures the projects and data created withearlier versions of the PCM600 tool , which enables fullbackwards V2 ENFigure 1.

6 PCM600 connected locally or remotely to IEDs2. Project explorerThe project explorer can be used to navigate to the used IEDswithin a project / substation and furthermore within an IED tonavigate to the different functionality of an IED. The user isable to create a plant structure with a substation, voltagelevels, bays and IEDs can also be created by use of IED templates. Thisenables the reuse of existing IED configurations. IEDs, bays,voltage levels or a whole substation can be copied andpasted in the plant structure. Selection of a specific IED in theproject explorer gives access to the IED s tools. The functionof importing and exporting descriptions of IEC 61850substation configurations, configured devices and devicefunctionality allows information to be shared with otherProtection and Control IED Manager1 MRS756448 KPCM600 Product version: : 2013-12-10 Revision: KABB3engineering and system integration tools.

7 By using thefiltering feature of the project explorer the user can filterinformation of other tools according to the selection Parameter settingThe parameter setting of PCM600 enables viewing andsetting IED parameters offline (stored in the tool ) and online(stored in both the tool and the IED). The parameters can beread from the IED to PCM600 or written from PCM600 to theIED while the IED is in service. In addition, the parameters canbe exported and imported for test sets in the XRIO format (forexample, Omicron Test Universe) or exported in the CSVformat to be easily read and parameter setting function can be used in two differentmodes. The normal mode allows a quick viewing andchanging of the most commonly used parameters, whereasthe advanced mode unveils all parameters that can be further offers a filtering function that allows theviewing of all IED parameters or the parameters related to aspecific function block.

8 In addition, it can be chosen to onlyview parameters that have been changed or parameters withvalues deviating from the IED s setting. Changed parameterswith different values in the tool and in the IED are V1 ENFigure 2. Parameter setting viewThe graphical representation of the distance protectionfunction supports in the visual verification of the parametersetting of the distance Protection V1 ENFigure 3. Graphical representation of the distance protectionfunction4. Graphical application configurationThe graphical application configuration functionality offerspowerful ways to create, adapt and modify applicationconfigurations, which also can be made as templates for laterre-use. PCM600 also enables presentation of the whole signalflow from input to output. It also assists the user during thecreation of application configuration through colourindications of the function blocks to ensure that themandatory inputs have been correctly connected.

9 Beforewriting the configuration to an IED, the tool offers validation ofthe complete IED configuration which ensures that theconfiguration does not contain , the user can compare the configuration in thetool to the one in the IED. Further, the signal status on-linemonitoring functionality helps to verify the real-time processesin the IED, which is extremely useful for and Control IED Manager1 MRS756448 KPCM600 Product version: 4 ABBGUID-62510AC1-D402-425C-A00D-FD0B9713 8922 V2 ENFigure 4. Application configuration, Online monitoringGUID-A565A681-95ED-4 CEC-B721-DD119 BEBE400 V2 ENFigure 5. Application configuration, visual indication of theconfiguration5. Signal matrixThe graphical signal matrix of PCM600 allows connectingefficiently CTs, VTs, binary input and output signals to theconfiguration. The configuration can also be changed fromhere. The tool can also be used for connecting the LEDs onthe IED as well as for connection of the GOOSE signalsbetween the the IEDs have been configured and parameterized, PCM600 enables the configuration of the horizontal bay-to-bay communication for station-wide interlocking and sendsthe complete IED description to a system engineering V2 ENFigure 6.

10 Signal matrix tool view6. Graphical display editorThe graphical display editor is used for configuring the displayof an IED. The graphical display consists of one or morepages. A display page contains the drawing area where theactual display configuration is made. A display is configuredby dragging predefined graphical symbols from a library tothe drawing area. The directed link tool can be used to drawconnections between symbols. Every symbol type has acorresponding representation in both the ANSI and the IECsymbol palettes. Symbols can be connected to theapplication graphical display editor also supports the reuse of displaypage templates made for other V2 ENFigure 7. Graphical display editor, configuring the display of an IEDP rotection and Control IED Manager1 MRS756448 KPCM600 Product version: ABB57. Hardware configurationThe hardware configuration can be used to get a quickoverview of an IED and to add or change hardware is possible to view the front and back of the IED includingcard information and their slot position.


Related search queries