Example: dental hygienist

PTX 651/671 - Veronics Instruments Inc.

GESensingPTX 651/671 PTX 651/671 is a Druck has joined other GEhigh technology sensingbusinesses under a new name GE Industrial, Ranges: psi (100 mbar) through 10,000 psi (700 bar)gauge or absolute Accuracy: full scale (FS), best fit straight line (BSL) Stability: FS per year Thermal effects: F ( C) Reliability: MTBF of 100 years NACE compatible High proof and containment pressures Certified intrinsically safe RFI protectedDruck Offshore/ProcessPressure TransducersPTX 671 PTX 651 The PTX 651 and PTX 671 process transmitters combinemicromachined silicon sensor technology with a fullywelded stainless steel/Hastelloy construction to provide ahigh accuracy, stable, rugged pressure transmitter.

GE Sensing PTX 651/671 PTX 651/671 is a Druck product. Druck has joined other GE high–technology sensing businesses under a new name–GE Industrial, Sensing.

Tags:

  Ptx 651 671, Ptx 651 671 ptx 651 671

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of PTX 651/671 - Veronics Instruments Inc.

1 GESensingPTX 651/671 PTX 651/671 is a Druck has joined other GEhigh technology sensingbusinesses under a new name GE Industrial, Ranges: psi (100 mbar) through 10,000 psi (700 bar)gauge or absolute Accuracy: full scale (FS), best fit straight line (BSL) Stability: FS per year Thermal effects: F ( C) Reliability: MTBF of 100 years NACE compatible High proof and containment pressures Certified intrinsically safe RFI protectedDruck Offshore/ProcessPressure TransducersPTX 671 PTX 651 The PTX 651 and PTX 671 process transmitters combinemicromachined silicon sensor technology with a fullywelded stainless steel/Hastelloy construction to provide ahigh accuracy, stable, rugged pressure transmitter.

2 Thesematerials and environmental protection are ideal forarduous applications such as offshore incorporating technology developed for demandingaerospace and military applications, the PTX 651/PTX 671provide excellent long term stability and feature minimaloutput noise, non-linearity and connections have been standardized as 1/2 NPTwith a choice of electrical connections, either 3/4 NPTfemale conduit or junction transmitter incorporates RFI/EMC spike protectionand is certified intrinsically the junction box is a quick disconnect featurewhich negates the need to remove heavy duty cableswhen changing Pressure RangeAny pressure unit and (zero based) span availablebetween 5 psi (350 mbar) and 10000 psi (700 bar) FS togauge and absolute formats.

3 Spans down to psi (100 mbar) available in gauge format x FS minimumProof x FS minimumTransmitter Supply Voltage9 to 30 VDCThis voltage must occur across the transmitter 651/671 SpecificationsStandardOutput Current4 to 20 mA (two-wire configuration) proportional for zeroto FS SealingType 4 in (119 mm)BLUERED123456 Nominal in(10 mm) in (38 mm)1/2-14 NPTPTX A/F HEXC onduit Entry3/4 in (41 mm) in(34 mm) in (61 mm) in (155 mm)1/2-14 in(38 mm)PTX 651 PTX 651/671 installation in (23 mm) in(17 mm) in(10 mm) in (23 mm)1500100050000102030 40 Under voltageareaOver voltageareaOperatingareaPowere Supply Voltage (VDC)Total Load Resistance (Ohms)Combined Non-linearity, Hysteresis and RepeatabilityTerminal definitionThe output will not deviate from the straight lineconnecting zero and FS output by more than FS(Typically FS).

4 Best fit straight line definition FS (Typically FS)Long Term StabilityAt standard reference conditions the calibration will notchange by more than FS/annum ( FS typical).Operating Temperature Range Ambient: -5 F to 175 F (-20 C to 80 C) Process media: -20 F to 250 F (-29 C to 121 C) Storage: -40 F to 250 F (-40 C to 121 C)Temperature EffectsFor ranges of 5 psi (350 mbar) and above, the outputwill not deviate from room temperaturecalibration by more than: FS over 15 F to 122 F or (-10 C to 50 C) or1% FS over -5 F to 175 F (-20 C to 80 C) Typically FS, 15 F to 122 F (-10 C to 50 C) FS, -5 F to 175 F (-20 C to 80 C)For ranges below 5 psi (350 mbar) these values willincrease pro-rata with calibration informationPlease state the following.

5 (1) Type numberPTXCode Description 651671 Code Temperature effect0 -15 F to 122 F (-26 C to 50 C)1 -5 F to 175 F (-20 C to 80 C)CodeElectrical connection5 3/4 NPT female conduit7 Junction boxPTX - ___ - ___ - ___Typical Model NumberSpecification otherwise the same as PTX 600 Series data 651/671 SpecificationsMaterial Compatibility 316L stainless steel/Hastelloy C276 All Hastelloy C276 (optional) All Monel 400 (optional)Weight PTX 651: lb ( kg) PTX 671: 4 lb ( kg)Intrinsic SafetyThese transmitters are certified for use with barriersystems to CSA and FM Certification Class I, Division 1,Groups A,B,C&D with a T4 temperature code.

6 ATEX certification available on Connection1/2 NPT maleFeatures1) Glass-filled polyester junction box (PTX 671)2) Aluminium bronze disconnect ring3) All 316 stainless steel welded body4) In-line diode for output current monitoring (PTX 671)5) Gold plated disconnect plug/socket (PTX 671)g 2006 GE. All rights specifications are subject to change for product improvement without is a registered trademark of General Electric Co. Other company or productnames mentioned in this document may be trademarks or registered trademarksof their respective companies, which are not affiliated with


Related search queries