Example: confidence

Quick Reference Guide Voyager™ 12½-25 Ton Packaged …

January 2015RT-PRC038G-EN 2015 Trane All rights reserved12 Quick Reference GuideVoya ge r 12 -25 Ton Packaged Rooftop UnitsCooling & Gas/ElectricTable number descriptionT*DCooling Only (Electric Heat Optional), DownflowT*HCooling Only (Electric Heat Optional), HorizontalY*DGas Heat Unit, DownflowY*HGas Heat Unit, Horizontal* Standard (S) or High (H) EfficiencyTable of factory installed options (FIOPs)(a)(a) Most Factory Installed Options are available for downflow air discharge units only. Verify with ordering system for MERV 8 or MERV 13 Pleated Filters w/ Removal Tool Horizontal Side Access with Disconnect SwitchBACnet Communication Interface (BCI)LonTalk Communication Interface (LCI)Barometric Relief(b) (c)(b) Requires an Economizer.(c) Some field set up Gas Heat Furnace w/ a :1 Turndown Ratio(d)(d) Requires ReliaTel Options Filter/Fan Failure Switch(d)Motor Shaft Grounding Ring(e)(e) Available with Two Speed Fan or Variable Speed Coat Microchannel Condenser CoilNOVAR Return Air SensorCondensate Overflow SwitchNOVAR Unit Controls (3051 and 2024)DCV HarnessOversized MotorsDehumidificationPowered/Unpowered Convenience Outlet(f)(f) Must be ordered with Through the Base Electrical option or Horizontal Side Access, and either Unit Mounted Disconnect switch or Circuit VAV(d)Stainless Steel Drain PanDischarge Air Sensing Kit(d)Stainless Steel Heat E

(c) EER is rated at ARI conditions and in accordance with ARI standard 210/240 or 340/360. 11 11 11 10.010.012.112.111.8 11.010.6 IEER (One Speed Fan / Multi or Variable Speed Fan)(d) (d)Integrated Energy Efficiency Ratio (IEER) is rated in accordance with AHRI standard 210/240 or …

Tags:

  Standards, Hari, Ahri standard

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Quick Reference Guide Voyager™ 12½-25 Ton Packaged …

1 January 2015RT-PRC038G-EN 2015 Trane All rights reserved12 Quick Reference GuideVoya ge r 12 -25 Ton Packaged Rooftop UnitsCooling & Gas/ElectricTable number descriptionT*DCooling Only (Electric Heat Optional), DownflowT*HCooling Only (Electric Heat Optional), HorizontalY*DGas Heat Unit, DownflowY*HGas Heat Unit, Horizontal* Standard (S) or High (H) EfficiencyTable of factory installed options (FIOPs)(a)(a) Most Factory Installed Options are available for downflow air discharge units only. Verify with ordering system for MERV 8 or MERV 13 Pleated Filters w/ Removal Tool Horizontal Side Access with Disconnect SwitchBACnet Communication Interface (BCI)LonTalk Communication Interface (LCI)Barometric Relief(b) (c)(b) Requires an Economizer.(c) Some field set up Gas Heat Furnace w/ a :1 Turndown Ratio(d)(d) Requires ReliaTel Options Filter/Fan Failure Switch(d)Motor Shaft Grounding Ring(e)(e) Available with Two Speed Fan or Variable Speed Coat Microchannel Condenser CoilNOVAR Return Air SensorCondensate Overflow SwitchNOVAR Unit Controls (3051 and 2024)DCV HarnessOversized MotorsDehumidificationPowered/Unpowered Convenience Outlet(f)(f) Must be ordered with Through the Base Electrical option or Horizontal Side Access, and either Unit Mounted Disconnect switch or Circuit VAV(d)Stainless Steel Drain PanDischarge Air Sensing Kit(d)Stainless Steel Heat ExchangerEconomizer - Low Leak/Downflow(c) Supply & Return Air Smoke Detectors(d)Economizer - Standard/Downflow (c)Through the Base Electrical with Circuit BreakerElectric HeatersThrough the Base Electrical with Disconnect SwitchFault Detection & Diagnostics (FDD)Through the Base Gas ProvisionFrostat (d)(g)(g)

2 Standard on high efficiency ol - le ss Ha il G ua r dHigh Efficiency MotorsTrane Communication Interface (TCI)(h)(h) TCI is for use with non-VariTrac systems and VariTrac Short Circuit Current Rated (SCCR) Electrical Subsystem(i)(i) Available on 208 V/60 Hz, 230 V/60 Hz, and 480 V/60 Hz Speed Fan ProvisionHinged Access PanelsVariable Speed Fan Provision for Single Zone VAVH orizontal Side Access with Circuit BreakerTable -25 ton Packaged rooftop performance data (gas or electric heat)Standard EfficiencyHigh EfficiencyNominal Size (Ton) 25 Cooling PerformanceNominal Airflow CFM / ARI Rated CFM5,000/4,4006,000/5,3007,000/6,1258,00 0/7,00010,000/8,0005,000/4,0006,000/5,25 07,000/5,6008,000/6,40010,000/8,000 Tot / Sens Cap (MBh)(a) (b)(a) Cooling performance is rated at 80/67/95 & 400 cfm/ton.(b) Short orifice metering (c)(c) EER is rated at ARI conditions and in accordance with ARI standard 210/240 or 340 11 11 (One Speed Fan / Multi or Variable Speed Fan)(d)(d) Integrated Energy Efficiency Ratio (IEER) is rated in accordance with ahri standard 210/240 or 340 Heating Performance(e)(e) Verify option availability in product data Heat (Input/output) - (MBh) Heat (Input/output) - (MBh) Heat (Input/output) - (MBh) InformationNet Weight (Lbs) - Gas Heat150819252007206920542207217621402211 2245 Net Weight (Lbs) - Electric Heat141318221863192518782062203019912061 2062 RoofcurbBAYCURB026 BBAYCURB027 BUnit Cabinet SizeBCC+Filters(f) - Type Furnished(f) Optional 2 MERV 8 and MERV 13 filters also Size RecommendedDownflow(2) 20x20x2 (4) 20x25x2(4) 20x20x2 (4) 20x25x2(4) 20x20x2 (4) 20x25x2(4) 20x20x2 (4) 20x25x2(4) 20x20x2 (4) 20x25x2(4) 20x20x2 (4) 20x25x2(8) 20x20x2 (4) 20x16x2(8) 20x20x2 (4)

3 20x16x2(8) 20x20x2 (4) 20x16x2(8) 20x20x2 (4) 20x16x2 Horizontal(2) 20x20x2 (4) 20x25x2(8) 20x25x2 (8) 20x25x2(8) 20x25x2(8) 20x25x2(8) 20x25x2(12) 20x20x2(12) 20x20x2(12) 20x20x2(12) 20x20x2453 The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leaderin creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio ofadvanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. 2015 Trane All rights reservedRT-PRC038G-EN 20 Jan 2015 Supersedes RT-PRC038F-EN (13 May 2014)We are committed to using environmentally conscious print practices that reduce MCA & MOP electrical data (standard indoor fan motor)

4 T/YS*VoltsMCAMOPT/YH*VoltsMCAMOP150208-2 30/36480150208-230/36590460/33140460/330 40575/32330575/32430380/33745180208-230/ 36890180208-230/375100460/33345460/33850 575/32635575/33140210208-230/386110380/3 4560460/34360210208-230/393125575/333454 60/34460240208-230/399125575/33550460/34 660380/35570575/33850240208-230/31081253 00208-230/3121150460/35270460/35770575/3 4460575/34450380/36380300208-230/3124150 460/35970575/34860380/37190 Table indoor fan data StandardHP - RPMO versizeHP - RPMT/YH*VoltsStandardHP - RPMO versizeHP - RPMT/YS*Volts150208-230/3208-230/3460/33 - 17405 - 3450150460/33 - 17405 - 3450575/3575/3380/35 - 3450N/A208-230/3180208-230/3180460/33 - 17405 - 3450460/33 - 17405 - 3450575/3575/3208-230/3380/35 - 3450N/A210460/35 - - 3470210208-230/3575/3460/35 - - 3470208-230/3575/3240460/35 - - 3470380 - 3470N/A575/3240208-230/3208-230/3460/35 - - 3470300460 - 3470N/A575/3575/3380 - 3470N/A300208-230/3460 - 3470N/A575/3380/3 Table dimensional dataBCC+Unit Length UL106 11/16122 5/16122 5/16 Unit Width UW70 13/1684 3/1684 3/16 Unit Height UH 50 1/85464 1/8 Clearance C1606060 Clearance C2484848 Clearance C336 1/836 1/836 1/8 Clearance C4383838 Clearance C5727272 Curb Length CL102 1/2116 7/8116 7/8 Curb Width CW678181 Supply Length SL(a)(a) Dimensions are for curb openings and not duct inserts.

5 Reference the product catalog for duct insert 1/228 9/1628 9/16 Supply Width SW(a)55 1/269 1/269 1/2 Return Length RL(a)20 7/822 1/422 1/4 Return Width RW(a)637777 RWRLSWSLCWCLULUWUH