Transcription of RadioRA 2 Visor Controls - Lutron Electronics
1 Lutron | 2 Visor Controls allow lights, shades / draperies, and other equipment to be controlled from the car with just a touch of a button on a Visor control Transmitter or a HomeLink compatible Visor control . Up to ten (10) Transmitters can be used with a Visor control Receiver. The Receiver provides two (2) Contact Closure Inputs (CCI) for integration with other systems and one (1) CCI for security systems. The CCIs can be configured to accept maintained or momentary contact closures. The security input is always a maintained Receiver also has four (4) maintained or momentary Contact Closure Outputs (CCO) to control up to four (4) garage doors or motorized and blank labels are included with the Visor Controls for naming scenes or buttons on both the Receiver and the Transmitter.
2 Model NumbersRR-VCRX-WH* Visor control ReceiverRR-VCRX-WHBA* Visor control Receiver for BrazilLR-3B-H-SW** Visor control Transmitter* Only available in White (WH).** Only available in Snow (SW). RadioRA 2 Visor ControlsRR-VCRX-WHVisor control ReceiverLR-3B-H-SWVisor control TransmitterHomeLink and the HomeLink Compatible logo are registered trademarks of Johnson | Lutron 24/7 Technical Support 2 Visor ControlsSpecificationsModel NumbersRR-VCRX-WH, RR-VCRX-WHBA, LR-3B-H-SWPowerReceiver: 9 V 300 mADC adapter:Input: 120 V 60 Hz WOutput: 9 V 300 mATransmitter: 6 V 10 mA (2 - CR2032, included 10 year lifetime)Typical Power W Test conditions.
3 Two LEDs on (two presets active), powered by the 9 V adapter supplied, no CCOs or CCIs ApprovalsDC adapter: UL Listed for and Canada, NOMR eceiver / Transmitter: FCC, IC, COFETEL, ANATELE nvironmentReceiver: Ambient operating temperature: 32 F to 140 F (0 C to 60 C), 0% to 90% humidity, non-condensing. Indoor use : Ambient operating temperature: -40 F to 235 F (-40 C to 113 C), 0%-90% humidity, non-condensing. Meets the Society of Automotive Engineers (SAE) temperature Controls communicate with the system through Radio Frequency (RF).
4 The Receiver must be located within 30 ft (9 m) of a Repeater. The typical operating distance between a Receiver and a Transmitter is 150 ft (46 m). System devices operate on frequencies between MHz and ProtectionTested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC ProtectionTested to withstand surge voltages without damage or loss of operation, in accordance with IEEE Recommended Practice on Surge Voltages in Low-Voltage AC Power Receiver on a wall, ceiling, or level surface using the two #6 (M3) screws provided.
5 Clip Transmitter to a vehicle s Contact Closure Inputs, 1 security input, and 4 momentary or maintained Contact Closure Year Limited Warranty. Each output can be controlled locally at the Receiver or remotely by a Transmitter or keypad button. The Receiver Keypad or Inputs buttons can be programmed to light and shades / Features Full or Flash security options. The Transmitter can remotely control the Keypad , Security Input , and Outputs buttons on the Receiver. Lutron | dimensions are shown asVisor control ReceiverLearnVisor TransmitterKeypadOutputsFlashFullSecurit y InputInputs1 2 Power9 VInputsCFull1 C 2 COutputs3 C 4 CFlashReceiver (Front)Receiver (Side)2 3 4(70)6 1 4(159) RadioRA 2 Visor Controls1/4(6)4 1 4(108)1 1 16(27)3 3 4(95)Mounting Holes5 1 4(133)Transmitter (Front)Transmitter (Side)3/4(19)3 1 4(81)1 1 2(38)in(mm)
6 4 | Lutron 24/7 Technical Support 2 Visor ControlsMountingTransmitterReceiverVehic le VisorVerticalHorizontalWallLevel Surface#6 (M3) screw recommended (2 included)CeilingLutron | control ReceiverLearnVisor TransmitterKeypadOutputsFlashFullSecurit y InputInputs1 2 Power9 VInputsCFull1 C 2 COutputs3 C 4 CFlashLearnVisor TransmitterKeypadOutputsFlashFullSecurit y InputInputsRadioRA 2 Visor ControlsOperationOutput LEDsDisplay which CCOs are Input ButtonsPress and hold to test Security LEDs Display status of lights and shades / draperies programmed to the Keypad ButtonsPress to test LEDsDisplay status of ButtonsPress
7 To test CCI ButtonsPress to test keypad programming. Learn Button Press and hold for 3 seconds to enter Learn mode. Learn LEDF lashes to indicate that the Receiver is in Learn mode. Security Input LEDsTurn on when security mode is control Transmitter ButtonsPress to activate functions pre-printed or custom labels in depressions to name scenes / pre-printed or custom labels in depressions to name scenes / buttons6 | Lutron 24/7 Technical Support (Bottom)Receiver (Top)AntennaPower Jack (to adapter)IEC PELV / NEC Class 2 Contact Closure Outputs (CCO)Max Voltage / Current: See Relay Contact Ratings below.
8 IEC PELV / NEC Class 2 Minimum close time: 500 msContact Closure Terminal BlocksUse IEC PELV / NEC Class 2 cable Maximum 1000 ft (305 m)Each terminal holds up to one 16 AWG ( mm2) or two 18 AWG ( mm2) or smaller wire. Contact Closure Inputs (CCI)Dry contacts saturation: <1 V at 2 mAOFF leakage: <1 A at 9 VMinimum pulse time: 40 msVoltageResistive LoadInductive LoadUp to 30 V1 AUp to 30 V1 AUp to 60 ADo not Contact RatingsCommon - C(all inputs)Input 1 - 1 Security - Full FlashInput 2 - 2C - Common 4C - Common 3C - Common 2C - Common 14 - Output 43 - Output 32 - Output 21 - Output 1RF range.
9 To repeater 30 ft (9 m)To Transmitter 150 ft (46 m) RadioRA 2 Visor ControlsLutron | DiagramRadioRA 2 Visor ControlsSecurity SystemDryContactClosureInput( motion sensor)Output DeviceInput 2 Output 1 OCommon 1 CCommon CSecuritySCommonC( garage door)8 | Lutron Soporte t cnico las 24 horas del d a, los 7 d as de la semana del controles de visera RadioRA 2 permiten controlar luces, cortinas y dem s equipos desde el autom vil con tan s lo tocar un bot n de un transmisor del control de visera o de un control de visera compatible con HomeLink.
10 Se pueden utilizar hasta diez (10) transmisores con un receptor de control de receptor cuenta con dos (2) entradas de contacto seco (CCI) para la integraci n con otros sistemas y una (1) entrada de contacto seco para sistemas de seguridad. Las entradas CCI se pueden configurar para aceptar cierres sostenidos o moment neos. La entrada de seguridad siempre es s, el receptor tiene cuatro (4) salidas de contacto seco (CCO) sostenidos o moment neos para controlar hasta cuatro (4) puertas de garaje o portones motorizados.