The Failsafe Electro/HydraulicActuator consists of a singleacting spring return actuator forfail safe operation, mountedelectric motor, hydraulic pumpand reservoir. The actuator ismodified for hydraulic servicewhich includes a bleeder topurge air from the system. Thepump is driven by a totallyenclosed fan cooled single phasemotor. In the event of a powerloss, the valve will automaticallygo to the fail position (counter-clockwise or clockwise) by meansof the springs in the actuator. TECHNICAL DATA SHEETELECTRICRCM 700 Sureclose Actuators Increased or reduced speeds M-1 handwheel manual overrides Explosion proof motors, switches and solenoid valves Wash down motors Heater and thermostats Single phase 120 VAC, 220 VAC, 3-phase voltages 4-20MA DC 0 10 VDC, or 1-5 VDC for modulation 4-20MA DC feedback Other voltages available on requestOPTIONSNOTE:We prefer to quote actuator to valve mounting hardware in all casessince the power unit reservoir and actuator are provided as a Control Inc.

TORQUE OUTPUT *Larger torques available on request – POA HYDRAULIC PRESSURE SPRING Type Opens CCW Rotation Closes CW Rotation 0º 60º 90º 90º 30º 0º

Tags:

  Rcm 700 sureclose, Sureclose

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RCM 700 Sureclose Actuators

1 The Failsafe Electro/HydraulicActuator consists of a singleacting spring return actuator forfail safe operation, mountedelectric motor, hydraulic pumpand reservoir. The actuator ismodified for hydraulic servicewhich includes a bleeder topurge air from the system. Thepump is driven by a totallyenclosed fan cooled single phasemotor. In the event of a powerloss, the valve will automaticallygo to the fail position (counter-clockwise or clockwise) by meansof the springs in the actuator. TECHNICAL DATA SHEETELECTRICRCM 700 Sureclose Actuators Increased or reduced speeds M-1 handwheel manual overrides Explosion proof motors, switches and solenoid valves Wash down motors Heater and thermostats Single phase 120 VAC, 220 VAC, 3-phase voltages 4-20MA DC 0 10 VDC, or 1-5 VDC for modulation 4-20MA DC feedback Other voltages available on requestOPTIONSNOTE:We prefer to quote actuator to valve mounting hardware in all casessince the power unit reservoir and actuator are provided as a Control Inc.

2 Box 355 North Kingstown, RI 02852 Phone 401-294-1400 Fax401-294-3388 Email FEATURES Springs equal to 100 PSI torque output Limit switch to shut down pump when valve reaches open/closed position Two additional switches for open/close indication Painted carbon steel mounting brackets unless specified otherwise 4-20MA positioners in either weather or explosion proof verisionsTORQUE OUTPUT*Larger torques available on request POAHYDRAULIC PRESSURESPRINGTypeOpens CCW RotationCloses CW Rotation0 60 90 90 30 0 RCI 230 SRH-100/M404830310400635309460 RCI 240 SRH-100/M40416656658401330620930 RCI 250 SRH-100/M4042745975124019909301415 RCI 260 SRH-100/M404553021252655407019903010 RCI 265 SRH-100/M404714927823767633731354375 RCI 270 SRH-100/M4041115442905310841039805105 RCI 280 SRH-100/M4042212588501106017170832012480 RCI 88 SRH-100/M4044425017700221253429516595248 70 RCI 90 SRH-100/M4044425017257212403363015930243 37 RCI 100

3 SRH-100/M4048850035400442506858733187497 37 Pump: Gear-Type pump, capacity gallons/minute M404 Model. Opening and closing stroke times at +70 F ambient 230 SRH-100/M404 ..3 5 secondsRCI 240 SRH-100/M404 ..5 10 secondsRCI 250 SRH-100/M404 ..10 15 secondsRCI 260 SRH-100/M404 ..15 20 secondsRCI 265RH-100 35 secondsRCI 270 SRH-100/M404 ..35 50 secondsRCI 280 SRH-100/M404 ..75 100 secondsRCI 88 SRH-100/M404 ..250 300 secondsRCI 90 SRH-100/M404 ..150 200 secondsRCI 100 SRH-100/M404 ..250 300 secondsNOTE: Failure and power stroke times can be altered through variations of the standard DATA SHEETRCM 700 SurecloseTECHNICAL DATAPump PressureFactory set between 100 and 140 PSIM otor1/2 HP, 3450 RPM, 115/230/60, singlephaseOperating Temperature Range-5 F to 130 FOil TypeMobil DTE 24 or equivalentAB CRCI 230, 250, 270 RCI 240, 260 RCI 280 TECHNICAL DATA SHEETRCM 700 SurecloseRemote Control Inc. Box 355 North Kingstown, RI 02852 Phone 401-294-1400 Fax401-294-3388 Email RCI 88-SRRCI 100-SR