Relays & Sockets RH - IDEC

Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers773800-262-IDEC (4332) USA & CanadaRHRelays & SocketsRH Series Compact Power RelaysKey features SPDT through 4 PDT, 10A contacts Compact power type Relays Miniature power Relays with a large capacity 10A contact capacity Compact size saves spacePart Number SelectionPart NumberContactModelBlade TerminalPCB Termi-nalCoil Voltage Code(Standard Stock in bold)SPDTS tandardRH1B-U 0RH1V2-U 0AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110 VWith IndicatorRH1B-UL 0 With Check ButtonRH1B-UC 0 With Indicator and Check ButtonRH1B-ULC 0 Top Bracket MountingRH1B-UT 0 With Diode (DC coil only)RH1B-UD 0RH1V2-UD 0DC6V, DC12V, DC24V, DC48V, DC110 VWith Indicator and Diode (DC coil only)RH1B-ULD 0 DC12V, DC24V, DC48V, DC110 VDPDTS tandardRH2B-U 0RH2V2-U 0AC6V, AC12V, AC24V, AC110-120V, AC220-240V

(1 meter length) All DIN rail sockets BNDN1000 The BNDN1000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard length is 39” (1,000mm). DIN Rail End Stop DIN rail BNL5 9.1 mm wide. Replacement Hold-Down Spring Anchor

Tags:

  Early, Sockets, Meters, Relays amp sockets rh

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Relays & Sockets RH - IDEC

1 Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers773800-262-IDEC (4332) USA & CanadaRHRelays & SocketsRH Series Compact Power RelaysKey features SPDT through 4 PDT, 10A contacts Compact power type Relays Miniature power Relays with a large capacity 10A contact capacity Compact size saves spacePart Number SelectionPart NumberContactModelBlade TerminalPCB Termi-nalCoil Voltage Code(Standard Stock in bold)SPDTS tandardRH1B-U 0RH1V2-U 0AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110 VWith IndicatorRH1B-UL 0 With Check ButtonRH1B-UC 0 With Indicator and Check ButtonRH1B-ULC 0 Top Bracket MountingRH1B-UT 0 With Diode (DC coil only)RH1B-UD 0RH1V2-UD 0DC6V, DC12V, DC24V, DC48V, DC110 VWith Indicator and Diode (DC coil only)

2 RH1B-ULD 0 DC12V, DC24V, DC48V, DC110 VDPDTS tandardRH2B-U 0RH2V2-U 0AC6V, AC12V, AC24V, AC110-120V, AC220-240V DC6V, DC12V, DC24V, DC48V, DC100-110 VWith IndicatorRH2B-UL 0RH2V2-UL 0 With Check ButtonRH2B-UC 0 With Indicator and Check ButtonRH2B-ULC 0 Top Bracket MountingRH2B-UT 0 With Diode (DC coil only)RH2B-UD 0RH2V2-UD 0DC6V, DC12V, DC24V, DC48V, DC100-110 VWith Indicator and Diode (DC coil only)RH2B-ULD 0RH2V2-ULD 03 PDTS tandardRH3B-U 0RH3V2-U 0AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110 VWith IndicatorRH3B-UL 0RH3V2-UL 0 With Check ButtonRH3B-UC 0 With Indicator and Check ButtonRH3B-ULC 0 Top Bracket MountingRH3B-UT 0 With Diode (DC coil only)RH3B-UD 0 DC6V, DC12V, DC24V, DC48V, DC110 VWith Indicator and Diode (DC coil only)

3 RH3B-ULD 0 4 PDTS tandardRH4B-U 0RH4V2-U 0AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110 VWith IndicatorRH4B-UL 0RH4V2-UL 0 With Check ButtonRH4B-UC 0 With Indicator and Check ButtonRH4B-ULC 0 Top Bracket MountingRH4B-UT 0 With Diode (DC coil only)RH4B-UD 0RH4V2-UD 0DC6V, DC12V, DC24V, DC48V, DC110 VWith Indicator and Diode (DC coil only)RH4B-ULD 0 PCB terminal Relays are designed to mount directly to a circuit board without any Information When ordering, specify the Part No. and coil voltage code: (example) RH3B-U AC120V Part No.

4 Coil Voltage Code RHSwitches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit BreakersRHRelays & Sockets774 (for Blade Terminal Models)RelaysStandard DIN Rail Mount 1 Finger-safe DIN Rail Mount 1 Through Panel MountPCB MountRH1 BSH1B-05SH1B-O5 CSH1B-51SH1B-621. DIN Rail mount socket comes with two horseshoe clips. Do not use unless you plan to insert pullover wire spring. Replace-ment horseshoe clip part number is Down Springs & ClipsAppearanceItemRelayFor DIN Mount SocketFor Through Panel & PCB Mount SocketPullover Wire SpringRH1 BSY2S-02F1 2SY4S-51F12.

5 Must use horseshoe clip when mounting in DIN mount socket. Replacement horseshoe clip part number is Two required per 2RH3 BSH3B-05F1 2RH4 BSH4B-02F1 2 Leaf Spring (side latch)RH1B, RH2B, RH3B, RH4 BSFA-202 3 SFA-302 3 Leaf Spring (top latch)RH1B, RH2B, RH3B, RH4 BSFA-101 3 SFA-301 3 AC Coil RatingsVoltage (V)Rated Current (mA) 15% at 20 CCoil Resistance ( ) 10% at 20 COperation Characteristics(against rated values at 20 C)AC 50 HzAC 60 HzSPDTDPDT3 PDT4 PDTSPDTDPDT3 PDT4 PDTSPDTDPDT3 PDT4 PDTMax. Continuous Applied VoltagePickup VoltageDropout maximum30% 2,2001,800110-120 10,8007, 10,8007,360220-240 18,820 12,1009,120DC Coil RatingsVoltage (V)Rated Current (mA) 15% at 20 CCoil Resistance ( ) 10% at 20 COperation Characteristics(against rated values at 20 C)SPDTDPDT3 PDT4 PDTSPDTDPDT3 PDT4 PDTMax.

6 Continuous Applied VoltagePickup VoltageDropout Voltage612815024025047402524110%80% maximum10%minimum Standard coil volt-ages are in ,6602,6001,6001,550100-110 12,250 1108 ,800 8,6007,340 Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers775800-262-IDEC (4332) USA & CanadaRHRelays & SocketsContact RatingsMaximum Contact CapacityModelContinuous Current Allowable Contact PowerRated LoadResistive LoadInductive LoadVoltage (V)Res. LoadInd. LoadSPDT10A1540VA300W990VA210W110 AC10A7A220 DC10A7 ADPDT3 PDT4 PDT10A1650VA300W1100VA225W110 : Inductive load for the rated load cos = , L/R = 7 msT V RatingsVoltageRH1RH2RH3RH4240V DC10A10A10A10A AC: cos = , DC.

7 L/R = 0 msUL RatingsVoltageResistiveGeneral UseHorsepower RatingRH1RH2RH3RH4RH1RH2RH3RH4RH1RH2RH3R H4240V HP1/3 HP 120V AC 10A10A HP1/6 HP 30V DC10A10A 7A 28V DC 10A CSA RatingsVoltageResistiveGeneral UseHorse-power RatingRH1RH2RH3RH4RH1RH2RH3RH4RH1, 2, 3240V AC10A10A HP120V HP30V Socket SpecificationsSocketsTerminalElectrical RatingWire SizeTorqueDIN Rail Mount SocketsSH1B-05(Coil) M3 screws(contact) screws with captive wire clamp250V, 10 AMaximum up to 2 # - 9 in lbs9 - in screws with captive wire clamp300V, 10 AMaximum up to 2 #12 AWG9 - in lbsFinger-safe DIN Rail MountSH1B-05C(coil) M3 screws(contact) screws with captive wire clamp, fingersafe250V, 10 AMaximum up to 2 # - 9 in lbs9 - in screws with captive wire clamp, fingersafe300V, 10 AMaximum up to 2 #12 AWG9 - in lbsThroughPanel Mount SocketSH1B-51SH2B-51SH3B-51SH4B-51 Solder300V, 10A PCB Mount SocketSH1B-62 PCB mount250V, 10A SH2B-62SH3B-62SH4B-62 PCB mount300V, 10A AccessoriesItemAppearanceUse withPart DIN Rail (1 meter length)

8 All DIN rail socketsBNDN1000 The BNDN1000 is designed to accommodate DIN mount Sockets . Made of durable extruded aluminum, the BNDN1000 measures ( ) in height and (35mm) in width (DIN standard). Standard length is 39 (1,000mm).DIN Rail End StopDIN mm Hold-Down Spring Anchor DIN mount Sockets and hold down use on DIN rail mount socket when using pullover wire hold down spring. 2 pieces included with each & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit BreakersRHRelays & Sockets776 MaterialSilver cadmium oxideContact Resistance 150m maximumMinimum Applicable Load24V DC, 30 mA; 5V DC, 100 mA (reference value)Operating Time 2 SPDTDPDT20ms maximum3 PDT4 PDT25ms maximumRelease Time 2 SPDTDPDT20ms maximum3 PDT4 PDT25ms maximumPower Consumption (approx.)

9 SPDTAC: (50Hz), 1VA (60Hz) DC: : (50Hz), (60Hz) DC: : 2VA (50Hz), (60Hz) DC: : (50Hz), 2VA (60Hz) DC: Resistance100M minimum (500V DC megger)Dielectric Strength 3 SPDTB etween live and dead parts: 2,000V AC, 1 minuteBetween contact and coil: 2,000V AC, 1 minuteBetween contacts of the same pole: 1,000V AC, 1 minuteDPDT3 PDT4 PDTB etween live and dead parts: 2,000V AC, 1 minuteBetween contact and coil: 2,000V AC, 1 minuteBetween contacts of different poles: 2,000V AC, 1 minuteBetween contacts of the same pole: 1,000V AC, 1 minuteOperating FrequencyElectrical: 1,800 operations/hour maximumMechanical: 18,000 operations/hour maximumVibration ResistanceDamage limits: 10 to 55Hz, amplitude mmOperating extremes: 10 to 55Hz, amplitude mmShock ResistanceDamage limits: 1,000m/s2 (100G)Operating extremes: 200m/s2 (20G - SPDT, DPDT) 100m/s2 (10G - 3 PDT, 4 PDT)Mechanical Life50,000,000 operations minimumElectrical LifeDPDT500,000 operations minimum (120V AC, 10A)SPDT3 PDT4 PDT200,000 operations minimum (120V AC, 10A)Operating Temperature 4 SPDTDPDT3 PDT4 PDT 25 to +70 C (no freezing)Operating Humidity45 to 85% RH (no condensation)Weight (approx.)

10 SPDT: 24g, DPDT: 37g, 3 PDT: 50g, 4 PDT: 74g Note: Above values are initial Measured using 5V DC, 1A voltage drop method2. Measured at the rated voltage (at 20 C), excluding contact bouncing Release time of Relays with diode: 40 ms maximum3. Relays with indicator or diode: 1000V AC, 1 minute 4. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating temperature range of Relays with indicator or diode is 25 to +40 & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers777800-262-IDEC (4332) USA & CanadaRHRelays & SocketsCharacteristics (Reference Data)Electrical Life CurvesAC LoadDC Load135792468105020101005001000 Load Current (A)120V AC resistive240V AC inductive120V AC inductive240V AC resistiveLife ( 10,000 operations)(RH1)135792468105020101005001 000 Load Current (A)30V DC resistive100V DC inductive30V DC inductive100V DC resistiveLife ( 10,000 operations)(RH1)