Example: tourism industry

Release for general availability, 1FN3 linear motors in a ...

SIEMENS. Informazione di prodotto Industry Sector - drive Technologies Motion Control Starter SP2. Rif.: 80-13 Data: ID:64374921. Starter SP2. Aggiornamento: Con effetto immediato disponibile la versione di STARTER SP2 inclusi i pacchetti SSP (SINAMICS Support Packages). SSP SINAMICS SSP SINAMICS G120 SSP SINAMICS MV Starter SP2 supporta i seguenti azionamenti (Le nuove versioni sono indicate in grassetto): MICROMASTER 4th generation SINAMICS DCM with firmware , , SIMATIC ET200S FC with firmware , SIMATIC ET200pro FC with firmware SINAMICS G110 with firmware , SINAMICS G110D with firmware , SINAMICS G120 with firmware , , , , , , , , , and (with SSP). SINAMICS G120C with firmware , and (with SSP) SINAMICS G120D with firmware , , , and (with SSP) SINAMICS G120P with firmware , , , , SINAMICS G120P BT with firmware (with SSP) SINAMICS G130 with firmware , , , , , and SINAMICS G130 with firmware , , , and (with SSP) SINAMICS G150 with firmware , , , , , and SINAMICS G150 with firmware , , , and (with SSP) SINAMICS GM150 with firmware , and SINAMICS GM150 with firmware , , (--> SINAMICS MV).

SIEMENS Informazione di prodotto –Industry Sector - Drive Technologies – Motion Control Starter 4.3 SP2 Rif.: 80-13 Data: 04.04.2013 ID:64374921

Tags:

  Drive

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Release for general availability, 1FN3 linear motors in a ...

1 SIEMENS. Informazione di prodotto Industry Sector - drive Technologies Motion Control Starter SP2. Rif.: 80-13 Data: ID:64374921. Starter SP2. Aggiornamento: Con effetto immediato disponibile la versione di STARTER SP2 inclusi i pacchetti SSP (SINAMICS Support Packages). SSP SINAMICS SSP SINAMICS G120 SSP SINAMICS MV Starter SP2 supporta i seguenti azionamenti (Le nuove versioni sono indicate in grassetto): MICROMASTER 4th generation SINAMICS DCM with firmware , , SIMATIC ET200S FC with firmware , SIMATIC ET200pro FC with firmware SINAMICS G110 with firmware , SINAMICS G110D with firmware , SINAMICS G120 with firmware , , , , , , , , , and (with SSP). SINAMICS G120C with firmware , and (with SSP) SINAMICS G120D with firmware , , , and (with SSP) SINAMICS G120P with firmware , , , , SINAMICS G120P BT with firmware (with SSP) SINAMICS G130 with firmware , , , , , and SINAMICS G130 with firmware , , , and (with SSP) SINAMICS G150 with firmware , , , , , and SINAMICS G150 with firmware , , , and (with SSP) SINAMICS GM150 with firmware , and SINAMICS GM150 with firmware , , (--> SINAMICS MV).

2 SINAMICS GL150 with firmware , and SINAMICS GL150 with firmware , , (--> SINAMICS MV). SINAMICS S110 with firmware , , , SINAMICS S120 with firmware , , , , , and SINAMICS S120 with firmware , , , and (with SSP) SINAMICS S150 with firmware , , , , , and SINAMICS S150 with firmware , , , and (with SSP) SINAMICS SL150 with firmware , , (--> SINAMICS MV). SINAMICS SM120 with firmware (--> SINAMICS MV). SINAMICS MV (GM150/GL150/SL150/SM120) with firmware and (with SSP) Tutte le seguenti novit : Nuove funzioni della versione SP2. SINAMICS S120/S150/G130/G150/MV (GM150/GL150/SL150/SM120). SINAMICS G110/G120-2/G120C/G120D-2/G120P. DCC SINAMICS. Sono fornibili al seguente Link: NOVITA' STARTER SP2. Installazione Starter SP2: Starter pu essere installato nelle seguenti varianti: STARTER SP2 ha una sola impostazione per entrambe le varianti di installazione ("STARTER Standalone" e "STARTER DriveES").

3 Se non installato STEP 7, le varianti Standalone verr installato sul computer. Se STEP 7 installato sul computer, le varianti drive ES verr installato / aggiornato. (Nota: drive ES Basic non deve pi . essere installato come un prerequisito (a partire da STARTER SP2). STARTER integrato in SIMOTION SCOUT e SIMATIC S7- Technology non disponibile per la versione SP2. Funzionamento simultaneo di STARTER, SIMOTION SCOUT e SIMATIC S7-Technology in una partizione condivisa su un PG / PC non supportato. STARTER e StartDrive V12 pu essere installato in parallelo su una partizione condivisa. Ordinazione SINAMICS STARTER SP2: L'attuale versione di STARTER pu essere ordinata con il numero d'ordine (MLFB) 6SL3072-0AA00-0AG0 su DVD incl. certificato di licenza al prezzo di 30 per costi di l'elaborazione ordine.)

4 La versione corrente di STARTER ( SP2 o precedenti) possono essere scaricate al seguente Link: Download STARTER Requisiti di Sistema: Hardware PG or PC with Pentium III min. 1 GHz (recommended > 1 GHz). 1 GB RAM (recommended 2 GB). Screen resolution 1024 768 pixels, 16-bit color depth Free hard disk memory min. 3 GB. Software Microsoft Internet Explorer as of 32-bit operating systems: Microsoft Windows Server 2003 SP2. Microsoft Windows Server 2008. Microsoft Windows XP Professional SP2 **) and SP3. Microsoft Windows 7 Professional incl. SP1. Microsoft Windows 7 Ultimate incl. SP1. Microsoft Windows 7 Enterprise incl. SP1 (standard installation). 64-bit operating systems: Microsoft Windows 7 Professional SP1. Microsoft Windows 7 Ultimate SP1. Microsoft Windows 7 Enterprise SP1 (standard installation).

5 Microsoft Windows Server 2008 R2 SP1. Redatto da: I DT MC PRM.