Example: barber

REPORT NO. : E940698 EMC TEST REPORT

PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236. REPORT NO. : E940698 . EMC TEST REPORT . According to 1) EN 55022: 1998+A1: 2000+A2:2003. 2) EN 61000-3-2: 2000. 3) EN 61000-3-3: 1995+A1: 2001. 4) EN 55024: 1998+A1: 2001+A2:2003. EN 61000-4-2: 1995+A1: 1998+A2:2001 / EN 61000-4-3: 2002+A1:2002. EN 61000-4-4: 1995+A2: 2001 / EN 61000-4-5: 1995+A1: 2001. EN 61000-4-6: 1996+A1: 2001 / EN 61000-4-8: 1993+A1: 2001. EN 61000-4-11: 1994+A1: 2001. EUT Name Chipi Model No. UC232R. Applicant FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD.

REPORT NO. : E940698 Page 6 of 79 PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX ...

Tags:

  Report, Tests, Report on, E940698, E940698 emc test

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of REPORT NO. : E940698 EMC TEST REPORT

1 PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236. REPORT NO. : E940698 . EMC TEST REPORT . According to 1) EN 55022: 1998+A1: 2000+A2:2003. 2) EN 61000-3-2: 2000. 3) EN 61000-3-3: 1995+A1: 2001. 4) EN 55024: 1998+A1: 2001+A2:2003. EN 61000-4-2: 1995+A1: 1998+A2:2001 / EN 61000-4-3: 2002+A1:2002. EN 61000-4-4: 1995+A2: 2001 / EN 61000-4-5: 1995+A1: 2001. EN 61000-4-6: 1996+A1: 2001 / EN 61000-4-8: 1993+A1: 2001. EN 61000-4-11: 1994+A1: 2001. EUT Name Chipi Model No. UC232R. Applicant FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD.

2 Address 373 SCOTLAND ST.,GLASGOW G58QB SCOTLAND Test Engineer MICK CHOU. Reviewed by BARRY MA. Issued Date: SEP. 26, 2005. The test REPORT shall not be reproduced except in full, without the written approval of the laboratory. The REPORT can't be used by the client to claim product endorsement by PEP Testing Laboratory. This REPORT is only for the equipment which described in page 8. Page 1 of 79. PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236. REPORT NO. : E940698 . TABLE OF CONTENTS. 1. General 5.

3 General Information Place of Measurement Test Standards 2. Product Information 7. 3. EUT Description and Test Conclusion 8. 4. Modification(s) 9. 5. Test Software Used 9. 6. Support Equipment Used 10. 7. EN 55022 Conducted Disturbance Test 12. Test Limits Test Setup Photos Test Data 8. EN 55022 Radiated Disturbance Test 17. Test Description Test Setup Test Limits Test Setup photos Test Data 9. EN 61000-3-2 Harmonic Current Test 23. Test Description Flow-chart for determining Conformity Test Setup Test Limits Test Setup photo Test Data Page 2 of 79. PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St.

4 , Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236. REPORT NO. : E940698 . 10. EN 61000-3-3 Voltage Fluctuations Test 30. Test Description Test Limits Test Setup Photo Test Data 11. EN 61000-4-2 Electrostatic Discharge Test 34. Test Description Test Setup Test Limits Discharge Test Drawing Test Data 12. EN 61000-4-3 Radio-Frequency Electromagnetic Field Test 42. Test Description Test Block Diagram Test Limits Test Setup Photo 13. EN 61000-4-4 Fast Transient Burst Test 47. Test Description Test Setup Test Limits Test Setup Photo Test Data 14. EN 61000-4-5 Surge Immunity Test 53.

5 Test Description Test Setup Test Limits Test Setup Photo Test Data Page 3 of 79. PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236. REPORT NO. : E940698 . 15. EN 61000-4-6 Immunity To Conducted Disturbances, Induced By 59. Radio-Frequency Fields Test Description Test Setup Test Limits Test Setup Photo Test Data 16. EN 61000-4-8 Power Frequency Magnetic Field Immunity Test 65. Test Description Test Setup Test Limits Test Setup Photos 17. EN 61000-4-11 Voltage Dips, Short Interruptions and Voltage Variations 70.

6 Immunity tests Test Description Test Setup Test Limits Test Setup Photo Test Data 18. Labelling Requirement, Warning 75. 19. The List of Test Instruments 76. 20. EUT Photos 78. Page 4 of 79. PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236. REPORT NO. : E940698 . 1. General General Information : Applicant : FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. Address : 373 SCOTLAND ST.,GLASGOW G58QB SCOTLAND Manufacturer : FUTURE TECHNOLOGY DEVICES INTERNATIONAL LTD. Address : 373 SCOTLAND ST.,GLASGOW G58QB SCOTLAND Measurement Procedure : EN55022.

7 Measurement Uncertainty : The uncertainty of the testing result is given as below. The method of uncertainty Calculation is provided in PEP Testing Lab document No. QP-T-28-B & QP-T-27-B. Frequency ( MHz ) Д 30 30 Д 1000. Expanded Uncertainty c (dB) (dB). 95% Confidence Level; K=2. Place of Measurement PEP TESTING LABORATORY. 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL : 886-2-26922097 FAX : 886-2-26956236. NVLAP LAB CODE 200097-0. FCC Registration No. : 90868. NEMKO Aut. No. : ELA133. BSMI Aut. No. : SL2-IN-E-11. VCCI Registration No. : C-493/R-477.

8 Page 5 of 79. PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236. REPORT NO. : E940698 . Test Standards Tested for compliance with: EN 55022:1998 - Information Technology Equipment Radio disturbance +A1: 2000+A2: 2003 characteristics - Limits and methods of measurement EN 61000-3-2: 2000 - Electromagnetic compatibility (EMC) Part 3-2: Limits . Limits for harmonic current emissions (equipment input Current up to and including 16A per phase EN 61000-3-3: 1995 - Electromagnetic compatibility (EMC) Part 3-2: Limits.)

9 +A1: 2001 Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current up to 16A. EN 55024:1998 - Information technology equipment Immunity characteristics +A1: 2001+A2: 2003 Limits and methods of measurement EN 61000-4-2: 1995 - Electromagnetic compatibility (EMC) Part 4: Testing and +A1: 1998+A2: 2001 measurement techniques, Section 2: Electrostatic discharge immunity test Basic EMC Publication EN 61000-4-3: 2002 - Electromagnetic compatibility (EMC) Part 4: Testing and +A1: 2002 measurement techniques, Section 3: Radiated, radio- Frequency, electromagnetic field immunity test EN 61000-4-4: 1995 - Electromagnetic compatibility (EMC) Part 4: Testing and +A2.

10 2001 measurement techniques, Section 4: Electrical fast transient / Burst immunity test Basic EMC publication EN 61000-4-5: 1995 - Electromagnetic compatibility (EMC) Part 4: Testing and +A1: 2001 measurement techniques, Section 5: Surge immunity test (includes corrigendum: 1995). EN 61000-4-6: 1996 - Electromagnetic compatibility (EMC) Part 4: Testing and +A1: 2001 measurement techniques, Section 6: Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8: 1993 - Electromagnetic compatibility (EMC) Part 4: Testing and +A1: 2001 measurement techniques, Section 8: Power frequency magnetic field immunity test Basic EMC publication EN 61000-4-11: 1994 - Electromagnetic compatibility (EMC) Part 4: Testing and +A1: 2001 measurement techniques, Section 11: Voltage dips, short interruptions and voltage variations immunity tests Page 6 of 79.