Example: biology

ROTARY SCREW COMPRESSORS - Industrial Air …

Polar compressor ROTARY SCREW COMPRESSORS Revision .com 1 | P a g e Operating Instructions ROTARY SCREW COMPRESSORS Polar Air designs and manufactures products for safe operation. However, operators and maintenance persons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation. Keep these instructions for reference. Polar compressor ROTARY SCREW COMPRESSORS Revision .com 2 | P a g e Contents Page No Variable Speed Drive Information .. 1 Model Specification Charts .. 2-3 Safety Information.

Polar Compressor Rotary Screw Compressors Revision July.2015 www.eatoncompressor .com 877.283.7614 3 | P a g e Polar Air Rotary Screw Systems: 25 Hp - 60 Hp (VSD Compliant)

Tags:

  Compressor, Screw, Rotary, Rotary screw compressors, Rotary screw air, Compressor rotary screw compressors

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ROTARY SCREW COMPRESSORS - Industrial Air …

1 Polar compressor ROTARY SCREW COMPRESSORS Revision .com 1 | P a g e Operating Instructions ROTARY SCREW COMPRESSORS Polar Air designs and manufactures products for safe operation. However, operators and maintenance persons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation. Keep these instructions for reference. Polar compressor ROTARY SCREW COMPRESSORS Revision .com 2 | P a g e Contents Page No Variable Speed Drive Information .. 1 Model Specification Charts .. 2-3 Safety Information.

2 4 Tag Definitions .. 4 Basic Guidelines .. 4 Breathable Air .. 4 Pressurized Components .. 4 Personal Protective Equipment .. 4 Inspection .. 5 Forklift Safety .. 5 Lifting Safety .. 5 Installation .. 6 Area .. 6 Piping .. 6 Safety Steps .. 6 Installing .. 6 Oil Check .. 7-8 Electrical 8 Motor Rotation .. 9 System 9 Air Process .. 9 Lubrication Process .. 9 System Components .. 9 PLC (Programmable Logistical Control) .. 9 Setting:oC/oF; BAR/PSI; Lang; Time/Date . 10 Working Pressures .. 11 Clock Timer Settings .. 11 Working Timer Unloading Delay .. 12 Maintenance Notifications .. 13 Resetting Maintenance Alarms .. 13-15 Mechanical Components.

3 16-19 Resetting Overload Protection .. 16 Operation .. 19 Safety Rules .. 19-20 Initial Checks .. 20 Start-Up .. 21 Power Outages .. 21 Storage .. 21 Restarting Procedure .. 21 Maintenance .. 21 Safety Steps .. 21-22 Lubricating Oil .. 22 Changing 22 Oil Capacities .. 22 23 System Pressure .. 23 Safety Valve .. 23 Air/Oil Separator Filter .. 23 OPTIONAL: Cabinet Intake Filter(s) .. 23 Maintenance Schedule .. 24 Troubleshooting .. 25-29 Wiring Diagrams .. 29 Warranty .. 34 Variable Speed Drive The variable speed drive is an auxiliary feature available on all Polar Air COMPRESSORS . A variable speed drive or VSD regulates amp draw during start-up and motor speed during operation according to air demand.

4 All Polar Air COMPRESSORS are equipped with a VSD compliant motor, ventilated electrical box & adequate space in compressor cabinet for easy installation. The electronic controller (PLC) for the compressor unit provides start/stop command and display fault status for the VSD device. Be sure to install VSD in a clean, dust-free environment. To convert to Variable speed drive, contact Polar Air customer service for more information, 1-877-283-7614 VSD Device Dedicated Cooling Fan Wiring Access Area Each compressor cabinet has built-in VSD compartment Polar compressor ROTARY SCREW COMPRESSORS Revision .com 3 | P a g e Polar Air ROTARY SCREW Systems: 25 Hp - 60 Hp (VSD Compliant) Model 40HP208V:77208V:124 Amp Draw SF230V: 70230V:112460V: 35460V:56 RPM1750 Voltage208/230/460/575 208/230/460/575 208/230/460/575 SCFM @ 100 PSI108129 Start TypeY-Delta & VSDD rive TypeBeltAir End ModelB101/EVO6 Noise DB(a)7375 Outlet SizeNPT 1"Oil GALD imensions (inches) 43X48X62 Weight (lbs.)

5 1374 NPT 1-1/4" GAL54X51X652052 NPT 1-1/4" GAL54X51X652220261Y-Delta & VSDBeltEUDUR012/EV098154X51X65205260HP23 0V:161460V:811750 208/230/460/575 50HP1750235 Y-Delta & VSD BeltEUDUR012/EV0979 BeltEUDUR012/EV0979 NPT 1-1/4" GAL1750188 Y-Delta & VSDDual VoltageDual Voltage30HP230V:83208V:91 NPT 1" GAL43X48X621370Y-Delta & VSDBeltB101/EVO6208/230/460/575 PRS0300003 Three PhasePRS0400003 Three PhaseThree PhasePRS0600003 PRS0500003 Three PhaseDual VoltageThree PhaseDual VoltageDual Voltage460V:41208V:152 230V: 138 460V: 69208V:1781750 Model PhaseSingle PhaseSingle PhaseThree PhaseThree PhaseThree PhaseThree PhaseDual VoltageDual VoltageDual VoltageDual VoltageDual VoltageMotor5 Draw SF243240230V: 22230V: 30230V: 42230V: 57460V: 11460V: 15460V: 21460V.

6 29 RPM2810175017501750175017501750 Voltage208/230208/230208/230208/230/460/ 575208/230/460/575208/230/460/575208/230 /460/575 SCFM @ 100 PSI21294529456285 Start TypeMagneti c StarterMagnetic StarterMagnetic StarterY-Delta & VSDY-Delta & VSDY-Delta & VSDY-Delta & VSDD rive TypeBelt BeltBeltBeltBeltBeltBeltAir End ModelB40/EVO2B40/EVO2B40/EVO2B40/EVO2B40 /EVO2B60/EVO3B60/EVO3 Noise DB(a)60626462646785 Outlet SizeNPT 3/4"NPT 3/4"NPT 3/4"NPT 3/4"NPT 3/4"NPT 1"NPT 1"Oil gal GalDimensions (inches) 43x48x4343x48x4348x45x4843x48x4348x45x48 48x45x5048x45x50 Weight (lbs.)451542630542630788880 Polar Air ROTARY SCREW Systems: 5 Hp - 20 Hp (VSD Compliant) Polar compressor ROTARY SCREW COMPRESSORS Revision.

7 Com 4 | P a g e Polar Air ROTARY SCREW Systems: 75 Hp - 200 Hp (VSD Compliant) Model PhaseThree PhaseThree PhaseThree PhaseDual VoltageDual VoltageDual VoltageDual VoltageDual VoltageMotor75HP100HP125HP150HP175HP200 HPAmp Draw SF460V: 256 RPM175017501750175017501750 Voltage208/230/460208/230/460208/230/460 460460460 SCFM @ 100 PSI353424570706812883 Start TypeY-Delta & VSDY-Delta & VSDY-Delta & VSDY-Delta & VSDY-Delta & VSDY-Delta & VSDD rive TypeDirect DriveDirect DriveDirect DriveDirect DriveDirect DriveDirect DriveAir End ModelE25GE25GE75GE75GE75GE75 GNoise DB(a)788083838787 Outlet SizeNPT 2"NPT 2"NPT 3"NPT 3"NPT 3-1/2"NPT 3-1/2"Oil Capacity8 gal8 gal. 18182424 Dimensions (inches) 83x52x7286x56x73102X63X75102X63X7568X105 X7868"x105"x78"Weight (lbs.)

8 360636065800580065386538460V: 221208V:361230V: 327460V: 163460V: 188 Three PhaseThree PhaseDual Voltage230V:196460V: 98208V:216208V:290230V:262460V:131 Before installing your compressor it is imperative due to varying local wiring codes to consult a professional licensed electrician. Installation of electrical wire can be extremely hazardous, if done improperly, it can result in personal injury or property damage. Eaton compressor is not responsible for any damages incurred due to improper installation of any electrical lines or components. Safety This manual contains very important information on SAFETY and how to PREVENT EQUIPMENT PROBLEMS. The following will help in understanding this information: DANGER INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.

9 WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury. NOTICE indicates important information that if not followed, may cause damage to equipment. Read all manuals included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment. Polar compressor ROTARY SCREW COMPRESSORS Revision .com 5 | P a g e Basic Guidelines: CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals know to the State of California to cause cancer and birth defects or other reproductive harm.

10 Wash hands after handling. 1. Allow only trained, authorized persons who have read and understood these operating instructions to use this compressor . Failure to follow the instructions, procedures and safety precautions in this manual can result in accidents and injuries. 2. NEVER start or operate the compressor under unsafe conditions. Tag the compressor , disconnect and lock-out all power to it to prevent accidental start-up until the condition is corrected. 3. Install, use and operate the compressor only in full compliance with all pertinent OSHA regulations and all applicable Federal, State & Local codes, standards and regulations. 4. NEVER modify the compressor and/or controls in any way.


Related search queries