Example: dental hygienist

RSES/RSSS Raychem Screened Adaptor System 250 A, 24 kV …

RSES/RSSSR aychem Screened Adaptor System250 A, 24 kVEnergy DivisionEPP0473-04-07 14:52 Uhr Seite 1 Raychem Screened Adaptor System 250 A, 24 kVRayvolve SealingCold applied technology. Rayvolve is used in conjunction with a pressure sensitive mastic and is simply rolled into place. Thus a reliable moisture seal is achieved. The use of Rayvolve is particularlyrecommended for applications where a torch is unavailable or cannot be SealingMoisture seal and phase marking. A reliable moisture can also be produced by using a mastic in conjunction with a heat-shrinkablesleeve. This solution has the additionaladvantage of providing phase marking. A standard torch carried by most jointers is separable ScreenedAdaptors are designed to connect single-core polymeric cables to medium voltage equipment (trans-formers, switchgears, motors etc.) up to 24 of crosslinked EPDM and protected with a minimum 3 mmmoulded conductive shield connectedto earth, Raychem deadbreak adap-tors are suitable for both indoor andoutdoor wide application range allows aminimum number of bodies to coverseveral different cable cross-sectionswithout the need for additional cableadaptors.

RSES/RSSS Raychem Screened Adaptor System 250 A, 24 kV Energy Division EPP0473-04-07 23.04.2007 14:52 Uhr Seite 1. 24000 volts

Tags:

  System, Ssrs, Raychem, Adaptors, Screened, Rsss raychem screened adaptor system 250

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RSES/RSSS Raychem Screened Adaptor System 250 A, 24 kV …

1 RSES/RSSSR aychem Screened Adaptor System250 A, 24 kVEnergy DivisionEPP0473-04-07 14:52 Uhr Seite 1 Raychem Screened Adaptor System 250 A, 24 kVRayvolve SealingCold applied technology. Rayvolve is used in conjunction with a pressure sensitive mastic and is simply rolled into place. Thus a reliable moisture seal is achieved. The use of Rayvolve is particularlyrecommended for applications where a torch is unavailable or cannot be SealingMoisture seal and phase marking. A reliable moisture can also be produced by using a mastic in conjunction with a heat-shrinkablesleeve. This solution has the additionaladvantage of providing phase marking. A standard torch carried by most jointers is separable ScreenedAdaptors are designed to connect single-core polymeric cables to medium voltage equipment (trans-formers, switchgears, motors etc.) up to 24 of crosslinked EPDM and protected with a minimum 3 mmmoulded conductive shield connectedto earth, Raychem deadbreak adap-tors are suitable for both indoor andoutdoor wide application range allows aminimum number of bodies to coverseveral different cable cross-sectionswithout the need for additional cableadaptors.

2 The cut-back dimensions for all cable sizes are the same forRSSS and RSES. Raychem Screened adaptors areequipped with a capacitive test pointto ensure that the circuit is not energised before disconnection. The capacitive test point is protectedby a conductive cap. A range of highstrength bimetallic compression connectors tested to VDE 0220 areoffered to connect both aluminiumand copper conductor cable preparation and lubrication,the Raychem Screened adaptors cansimply be slid into place under virtuallyall conditions. A separable mountingsystem provides for an easy installa-tion of the Adaptor onto the addition, Rayvolve tubing or heat-shrink phase-marking sleeves areoffered as an option, to provide asuperior environmental 14:52 Uhr Seite 21 Screened BodyA 3 mm conductive moulded outerscreen is permanently bonded to the EPDM insulating material of the Capacitive Test PointUsed to determine if the circuit isenergised; can also be used for phasing.

3 Electrically protected by a cap made of Stress coneComputer designed, it relieves electrical stress at the cable screencut of the Conductive Cable EntranceThe 25 mm conductive end provides a connection to the cable and DesignRSES/RSSS5 Earthing EyeProvides a connection point for thescreen of the body to the Inner ScreenConductive insert provides a Faradaycage around the compression connec-tor and eliminates corona at Retaining ShoulderTo fix a retaining collar onto the Adaptor for easy installation with two Compression Pin-ConnectorBimetallic compression pin-connectordesigned with locking ring, to connectboth aluminium and copper conduc-tor Lifting EyeA lifting eye firmly attached to amoulded-in insert provides a secure connection PinTin plated copper electrode, designed and tested to carry 250 A continuous current. The hexagonal wrench to fix the pin onto connector is supplied with each Compression ConnectorBimetallic compression connector to connect both aluminium and copper conductor 14:52 Uhr Seite 3 Technical dataRSESRSSSC able Insulation Diameter - mm - mm Connector Cross section Range16 - 120 mm216 - 95 mm2 Maximum System Voltage24 kV24 kVContinuous Current Rating250 A250 ABasic Impulse Level125 kV125 kVPartial Discharge at 2 U0< 5 pc< 5 pcAC Voltage Withstand, 1 min 50 kV50 kVDC Voltage Withstand, 30 min 96 kV96 kVThe adaptors have been tested in accordance with the international specifications ( ANSI/IEEE 386, IEC 540, VDE 0278).

4 The bimetallic connectors have been tested in accordance with VDE 0220 on aluminium and copper adaptors pass the routine tests including: AC Voltage Withstand, Partial Discharge Extinction and Test Point Voltage TableScreened Elbow AdaptorsDiameter overCross section (Al or Cu conductor)insulation16 mm225 mm235 mm250 mm270 mm295 mm2120 - mmRSES 5201 RSES 5202 RSES 5203 RSES 5205 - mmRSES 52 1 1 RSES 52 1 2 RSES 52 1 3 RSES 52 1 5 RSES 52 1 7 RSES 52 1 9 - mm RSES 5223 RSES 5225 RSES 5227 RSES 5229 RSES - mm RSES 5235 RSES 5237 RSES 5239 RSES 5234 - mm RSES 5249 RSES 5244 Screened Straight AdaptorsDiameter overCross section (Al or Cu conductor)insulation16 mm225 mm235 mm250 mm270 mm295 - mmRSSS 5201 RSSS 5202 RSSS 5203 RSSS 5205 - mmRSSS 52 1 1 RSSS 52 1 2 RSSS 52 1 3 RSSS 52 1 5 RSSS 52 1 7 RSSS 52 1 - mm RSSS 5223 RSSS 5225 RSSS 5227 RSSS - mm RSSS 5255 RSSS 5257 RSSS 5259 Add mod.

5 Code -R to kit number for cold applied tubing mod. code -P to kit number for heat shrink tubing with phase Screened Adaptor System 250 A, 24 kVRSES/RSSSTyco Electronics Raychem GmbH Energy DivisionFinsinger Feld 1, 85521 Ottobrunn/Munich, GermanyPhone: +49-89-6089-0 Fax: +49-89-6096345 Division economical solutions for the electrical power industry: cable accessories, connectors & fittings, electricalequipment, instruments, lighting controls, insulators & insulation enhancement and surge arresters. All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct andreliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of anyparticular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements.

6 Our liability for these products is set forth in our standard terms and conditions of sale. Raychem , TE Logo and Tyco Electronics are trademarks. Tyco Electronics EPP 0473 4/07 EPP0473-04-07 14:52 Uhr Seite 4