SE and SE Cable - CME Wire

SEU and SER Cables Ampacity Data SEU & SER Cables (Service Entrance Cable ), xlpe insulated , 600 V. Copper Conductors Aluminum Conductors Size AWG 60 C 75 C 90 C Dwelling Size AWG 60 C 75 C 90 C Dwelling 8-8-8 40 50 55 . 6-6-6 55 65 75 6-6-6 40 50 55 . 4-4-4 70 85 95 100 4-4-4 55 65 75 . 2-2-2 95 115 130 125 2-2-2 75 90 100 100. 1-1-1 110 130 145 150 1-1-1 85 100 115 110. 1/0-1/0-1/0 125 150 170 175 1/0-1/0-1/0 100 120 135 125. 2/0-2/0-2/0 145 175 195 200 2/0-2/0-2/0 115 135 150 150. 3/0-3/0-3/0 165 200 225 225 3/0-3/0-3/0 130 155 175 175. 4/0-4/0-4/0 195 230 260 250 4/0-4/0-4/0 150 180 205 200. NEC Table (B)(16) (formerly Table ), and Table (B)(7).Allowable Ampacities of insulated Conductors Rated Up to and Including 2000 Volts, 60 C. Through 90 C, Not More Than Three Current-Carrying Conductors in Raceway, Cable , or Earth (Directly Buried), Based on Ambient Temperature of 30 C.

(Service Entrance Cable), XLPE Insulated, 600 V Size AWG Copper Conductors 60 °C 75 °C 90 °C Dwelling 8-8-8 40 50 55 – ...

Tags:

  Cable, Insulated, Xlpe, Xlpe insulated

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SE and SE Cable - CME Wire

1 SEU and SER Cables Ampacity Data SEU & SER Cables (Service Entrance Cable ), xlpe insulated , 600 V. Copper Conductors Aluminum Conductors Size AWG 60 C 75 C 90 C Dwelling Size AWG 60 C 75 C 90 C Dwelling 8-8-8 40 50 55 . 6-6-6 55 65 75 6-6-6 40 50 55 . 4-4-4 70 85 95 100 4-4-4 55 65 75 . 2-2-2 95 115 130 125 2-2-2 75 90 100 100. 1-1-1 110 130 145 150 1-1-1 85 100 115 110. 1/0-1/0-1/0 125 150 170 175 1/0-1/0-1/0 100 120 135 125. 2/0-2/0-2/0 145 175 195 200 2/0-2/0-2/0 115 135 150 150. 3/0-3/0-3/0 165 200 225 225 3/0-3/0-3/0 130 155 175 175. 4/0-4/0-4/0 195 230 260 250 4/0-4/0-4/0 150 180 205 200. NEC Table (B)(16) (formerly Table ), and Table (B)(7).Allowable Ampacities of insulated Conductors Rated Up to and Including 2000 Volts, 60 C. Through 90 C, Not More Than Three Current-Carrying Conductors in Raceway, Cable , or Earth (Directly Buried), Based on Ambient Temperature of 30 C.

2 Building Wire CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | 2014 CME Wire and Cable , Inc. All Rights Reserved. January 14, 2016. SEU and SER Cables Ampacity Data This page intentionally left blank CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | January 14, 2016 2014 CME Wire and Cable , Inc. All Rights Reserved.


Related search queries